Minghua Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Minghua Huang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chenlu Li
School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Fangxiong Wang
School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Haihang Cui
School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Jinggang Zhang
School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Junhui Liao
School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Kuan Chen
School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication
Latest Publications
- Open Access
- 3 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9803
The Coupling and Desynchronization of Magnetic Microsphere Dimers Under a Rotating Magnetic Field
Magnetically driven colloids provide a simple platform for studying synchronization and nonlinear dynamics in externally driven many-body systems. Although desynchronization of an individual magnetic particle is well established, a particle pair contains coupled rotational degrees of freedom whose synchronization pathways remain less understood. Here, we experimentally investigate single magnetic microspheres and microsphere dimers in a viscous fluid under a rotating magnetic field across a wide frequency range. As the driving frequency increases, the dimer passes through four characteristic regimes, from synchronous near-contact rotation to asynchronous radial breathing and fully desynchronized motion. The collective revolution of the dimer loses phase locking with the field before the spin of an individual microsphere, revealing a two-level synchronization structure. We evaluate the instantaneous magnetic interaction using the full dipole–dipole force rather than assuming a radial hydrodynamic force. The results indicate that radial breathing arises from phase-dependent dipolar forcing associated with loss of collective phase locking, whereas low-Reynolds-number hydrodynamics primarily contributes viscous resistance and rotational coupling. These findings link particle spin, collective revolution, and radial breathing through their relative phases and provide a mechanistic framework for understanding and controlling magnetically driven colloidal assemblies.
- 3 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9803
Open AccessThe Coupling and Desynchronization of Magnetic Microsphere Dimers Under a Rotating Magnetic Field
Magnetically driven colloids provide a simple platform for studying synchronization and nonlinear dynamics in externally driven many-body systems. Although desynchronization of an individual magnetic particle is well established, a particle pair contains coupled rotational degrees of freedom whose synchronization pathways remain less understood. Here, we experimentally investigate single magnetic microspheres and microsphere dimers in a viscous fluid under a rotating magnetic field across a wide frequency range. As the driving frequency increases, the dimer passes through four characteristic regimes, from synchronous near-contact rotation to asynchronous radial breathing and fully desynchronized motion. The collective revolution of the dimer loses phase locking with the field before the spin of an individual microsphere, revealing a two-level synchronization structure. We evaluate the instantaneous magnetic interaction using the full dipole–dipole force rather than assuming a radial hydrodynamic force. The results indicate that radial breathing arises from phase-dependent dipolar forcing associated with loss of collective phase locking, whereas low-Reynolds-number hydrodynamics primarily contributes viscous resistance and rotational coupling. These findings link particle spin, collective revolution, and radial breathing through their relative phases and provide a mechanistic framework for understanding and controlling magnetically driven colloidal assemblies.
- Open Access
Numerical Simulation Study on the Energy Benefits and Environmental Impacts of BIPV Installation Configurations and Positions at the Street Canyon Scale
Building-integrated photovoltaic (BIPV) systems play a pivotal role in advancing low-carbon urban transformation. However, replacing conventional building envelope materials with photovoltaic (PV) panels modifies heat transfer processes and airflow patterns, potentially influencing urban environmental quality. This study examines the impacts of BIPV on building energy efficiency, PV system performance, and street canyon micro-climates, including airflow, temperature distribution, and pollutant dispersion, under perpendicular wind speeds ranging from 0.5 to 4 m/s, across three installation configurations and three installation positions. Results indicate that rooftop PV panels outperform facade-mounted systems in power generation. Ventilated PV configurations achieve optimal energy production and thermal insulation, thereby reducing building cooling loads and associated electricity consumption. Moreover, BIPV installations enhance street canyon ventilation, improving pollutant removal rates: ventilation rates increased by 1.43 times (rooftop), 3.02 times (leeward facade), and 2.09 times (windward facade) at 0.5 m/s. Correspondingly, canyon-averaged pollutant concentrations decreased by 30.1%, 87.7%, and 85.9%, respectively. However, the introduction of facade PV panels locally reduces pedestrian thermal comfort, particularly under low wind conditions, but this negative effect is significantly alleviated with increasing wind speed. To quantitatively evaluate BIPV-induced micro-climatic impacts, this study introduces the Pollutant-Weighted Air Exchange Rate (PACH)—a metric that weights the air exchange rate by pollutant concentration—providing a more precise indicator for evaluating micro-environmental changes. These findings offer quantitative evidence to guide urban-scale BIPV deployment, supporting the integration of renewable energy systems into sustainable urban design.
Open AccessNumerical Simulation Study on the Energy Benefits and Environmental Impacts of BIPV Installation Configurations and Positions at the Street Canyon Scale
Building-integrated photovoltaic (BIPV) systems play a pivotal role in advancing low-carbon urban transformation. However, replacing conventional building envelope materials with photovoltaic (PV) panels modifies heat transfer processes and airflow patterns, potentially influencing urban environmental quality. This study examines the impacts of BIPV on building energy efficiency, PV system performance, and street canyon micro-climates, including airflow, temperature distribution, and pollutant dispersion, under perpendicular wind speeds ranging from 0.5 to 4 m/s, across three installation configurations and three installation positions. Results indicate that rooftop PV panels outperform facade-mounted systems in power generation. Ventilated PV configurations achieve optimal energy production and thermal insulation, thereby reducing building cooling loads and associated electricity consumption. Moreover, BIPV installations enhance street canyon ventilation, improving pollutant removal rates: ventilation rates increased by 1.43 times (rooftop), 3.02 times (leeward facade), and 2.09 times (windward facade) at 0.5 m/s. Correspondingly, canyon-averaged pollutant concentrations decreased by 30.1%, 87.7%, and 85.9%, respectively. However, the introduction of facade PV panels locally reduces pedestrian thermal comfort, particularly under low wind conditions, but this negative effect is significantly alleviated with increasing wind speed. To quantitatively evaluate BIPV-induced micro-climatic impacts, this study introduces the Pollutant-Weighted Air Exchange Rate (PACH)—a metric that weights the air exchange rate by pollutant concentration—providing a more precise indicator for evaluating micro-environmental changes. These findings offer quantitative evidence to guide urban-scale BIPV deployment, supporting the integration of renewable energy systems into sustainable urban design.