Yuxuan Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuxuan Hu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Bingyang Feng
State Grid Hubei Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan 430077, China
4 shared publications - Yiqun Kang
State Grid Hubei Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan 430077, China
3 shared publications - Haozhe Xiong
State Grid Hubei Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan 430077, China
2 shared publications - Qiangsheng Li
College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling 712100, China
2 shared publications - Qinyue Tan
College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling 712100, China
2 shared publications - Fangbin Yan
State Grid Hubei Electric Power Research Institute, State Grid Hubei Electric Power Co., Ltd., Wuhan 430077, China
1 shared publication
Latest Publications
- Open Access
- 21 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3744
Optimal Operation Strategy of Power Grids Integrated with High-Capacity Grid-Supporting Storage Devices Based on Trajectory Sensitivity Analysis and Improved Chaotic PSO Algorithm
High penetration levels of renewable energy and power electronic apparatus create prominent obstacles for novel power grids, which mainly manifested as inadequate system inertia and a deteriorated stability margin. To overcome such drawbacks, this research develops an operational control method to maintain safe and steady grid operation with large-capacity grid-forming energy storage connected to the system. This paper first builds a dynamic voltage model covering grid-forming energy storage, distributed renewable generators, and distribution network frameworks. Then it explores how different control parameter settings of grid-forming storage affect dynamic voltage regulation capabilities under distinct R-L ratio scenarios. Since the correlation between energy storage control variables and voltage regulation features is highly nonlinear and complicated, trajectory sensitivity analysis is adopted to linearize these coupling constraints, which are further embedded into the power system security operation mathematical model. A chaotic particle swarm optimization (PSO) algorithm is used to solve the constructed optimization model. Simulation tests on a modified IEEE 33-bus test system ultimately prove that the proposed method is reliable and practically applicable. Simulation results on the modified IEEE 33-bus test system demonstrate that the proposed strategy restricts grid voltage fluctuation rate to only 2.41%, raises renewable energy accommodation rate up to 98.4%, and achieves a 30.6% reduction in overall system operation cost compared to traditional energy storage configuration schemes, which fully verifies the outstanding effectiveness and practical engineering feasibility of the proposed method.
- 21 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3744
Open AccessOptimal Operation Strategy of Power Grids Integrated with High-Capacity Grid-Supporting Storage Devices Based on Trajectory Sensitivity Analysis and Improved Chaotic PSO Algorithm
High penetration levels of renewable energy and power electronic apparatus create prominent obstacles for novel power grids, which mainly manifested as inadequate system inertia and a deteriorated stability margin. To overcome such drawbacks, this research develops an operational control method to maintain safe and steady grid operation with large-capacity grid-forming energy storage connected to the system. This paper first builds a dynamic voltage model covering grid-forming energy storage, distributed renewable generators, and distribution network frameworks. Then it explores how different control parameter settings of grid-forming storage affect dynamic voltage regulation capabilities under distinct R-L ratio scenarios. Since the correlation between energy storage control variables and voltage regulation features is highly nonlinear and complicated, trajectory sensitivity analysis is adopted to linearize these coupling constraints, which are further embedded into the power system security operation mathematical model. A chaotic particle swarm optimization (PSO) algorithm is used to solve the constructed optimization model. Simulation tests on a modified IEEE 33-bus test system ultimately prove that the proposed method is reliable and practically applicable. Simulation results on the modified IEEE 33-bus test system demonstrate that the proposed strategy restricts grid voltage fluctuation rate to only 2.41%, raises renewable energy accommodation rate up to 98.4%, and achieves a 30.6% reduction in overall system operation cost compared to traditional energy storage configuration schemes, which fully verifies the outstanding effectiveness and practical engineering feasibility of the proposed method.
- Open Access
- 15 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (10) , 2120
Calibrated Context-Aware Security-as-a-Service Orchestration for New-Energy and Energy-Storage Stations
New-energy plants and battery energy-storage stations increasingly depend on software-defined supervision, remote maintenance, and event-driven control, which makes cyber protection inseparable from operational responsiveness. This study presents a calibrated context-aware Security-as-a-Service orchestration framework, denoted SECaaS-CARO, for station-oriented adaptive risk control. The framework separates field assets, control services, security services, and an adaptive decision layer, and it uses a monotone nine-indicator risk score whose weights are calibrated from the training split rather than fixed heuristically. A validation-based threshold search maps that score to low-, medium-, and high-intensity service chains so that protection strength changes with session context instead of remaining static. A reproducible semi-synthetic dataset containing 17,000 station sessions was used to emulate operator login, remote maintenance, gateway misuse, and malicious command scenarios. Across 10 independently resampled 5000-session test streams, SECaaS-CARO achieved an F1 score of 0.973, a blocking success of 0.965, and the highest deployment utility of 1.173 while reducing mean latency to 21.28 ms compared with 27.06 ms for Logistic-Fixed and 28.15 ms for RandomForest-Fixed. The results indicate that an interpretable calibrated service-orchestration policy can preserve near-supervised detection quality while materially improving deployment-oriented efficiency for new-energy and energy-storage stations.
- 15 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (10) , 2120
Open AccessCalibrated Context-Aware Security-as-a-Service Orchestration for New-Energy and Energy-Storage Stations
New-energy plants and battery energy-storage stations increasingly depend on software-defined supervision, remote maintenance, and event-driven control, which makes cyber protection inseparable from operational responsiveness. This study presents a calibrated context-aware Security-as-a-Service orchestration framework, denoted SECaaS-CARO, for station-oriented adaptive risk control. The framework separates field assets, control services, security services, and an adaptive decision layer, and it uses a monotone nine-indicator risk score whose weights are calibrated from the training split rather than fixed heuristically. A validation-based threshold search maps that score to low-, medium-, and high-intensity service chains so that protection strength changes with session context instead of remaining static. A reproducible semi-synthetic dataset containing 17,000 station sessions was used to emulate operator login, remote maintenance, gateway misuse, and malicious command scenarios. Across 10 independently resampled 5000-session test streams, SECaaS-CARO achieved an F1 score of 0.973, a blocking success of 0.965, and the highest deployment utility of 1.173 while reducing mean latency to 21.28 ms compared with 27.06 ms for Logistic-Fixed and 28.15 ms for RandomForest-Fixed. The results indicate that an interpretable calibrated service-orchestration policy can preserve near-supervised detection quality while materially improving deployment-oriented efficiency for new-energy and energy-storage stations.
- Open Access
A Hybrid Heuristic–Benders Method for Wind–Hydrogen Investment Planning with Non-Analytical Cost Functions
This paper studies capacity planning for a wind–hydrogen integrated energy system under scenario-based uncertainty in wind generation, hydrogen demand, and electricity prices. The model is formulated as a two-stage stochastic program in which first-stage investment decisions are selected before uncertainty is realized and second-stage hourly operation is optimized for each representative scenario. The main methodological difficulty is that part of the first-stage hydrogen-storage investment cost may be available only through a non-analytical evaluator, such as supplier quotation logic, simulation software, or a data-driven estimator, while the operational recourse model remains linear. To address this setting, a hybrid heuristic–Benders framework, denoted as GSOA-Benders, is developed by coupling the General-Soldiers Optimization Algorithm for derivative-free first-stage search with Benders cuts generated from linear programming subproblems. The framework is not presented as a replacement for commercial solvers on explicit convex or mixed-integer models; rather, it is intended for cases where exact algebraic reformulation of the first-stage cost is unreliable or unavailable. In the black-box case study with 500 scenarios, the method converges in 35.86 s and obtains an investment plan expressed as , corresponding to wind-farm construction, a 0.53 MW electrolyzer, a 23.23 MWh hydrogen tank, and no fuel-cell investment. Additional discussion is provided on stability-gap interpretation, benchmark limitations, component lifetime assumptions, hydrogen losses, and environmental extensions.Open AccessA Hybrid Heuristic–Benders Method for Wind–Hydrogen Investment Planning with Non-Analytical Cost Functions
This paper studies capacity planning for a wind–hydrogen integrated energy system under scenario-based uncertainty in wind generation, hydrogen demand, and electricity prices. The model is formulated as a two-stage stochastic program in which first-stage investment decisions are selected before uncertainty is realized and second-stage hourly operation is optimized for each representative scenario. The main methodological difficulty is that part of the first-stage hydrogen-storage investment cost may be available only through a non-analytical evaluator, such as supplier quotation logic, simulation software, or a data-driven estimator, while the operational recourse model remains linear. To address this setting, a hybrid heuristic–Benders framework, denoted as GSOA-Benders, is developed by coupling the General-Soldiers Optimization Algorithm for derivative-free first-stage search with Benders cuts generated from linear programming subproblems. The framework is not presented as a replacement for commercial solvers on explicit convex or mixed-integer models; rather, it is intended for cases where exact algebraic reformulation of the first-stage cost is unreliable or unavailable. In the black-box case study with 500 scenarios, the method converges in 35.86 s and obtains an investment plan expressed as , corresponding to wind-farm construction, a 0.53 MW electrolyzer, a 23.23 MWh hydrogen tank, and no fuel-cell investment. Additional discussion is provided on stability-gap interpretation, benchmark limitations, component lifetime assumptions, hydrogen losses, and environmental extensions. - Open Access
Coordinated Control Strategy for Active–Reactive Power in High-Proportion Renewable Energy Distribution Networks with the Participation of Grid-Forming Energy Storage
The high proportion of renewable energy connected to the grid has resulted in insufficient consumption capacity in distribution networks, while the construction of new-type power distribution systems has imposed higher reliability requirements. With its flexible power synchronization control capabilities, grid-forming energy storage systems possess the ability to both promote the consumption of distributed energy resources in new-type distribution networks and enhance their reliability. However, current control methods are still hindered by drawbacks such as high computational complexity and a singular optimization objective. To address this, this paper proposes an optimized strategy for unified active–reactive power coordinated control in high-proportion renewable energy distribution networks with the participation of multiple grid-forming energy storage systems. Firstly, to optimize the parameters of grid-forming energy storage systems more accurately, this paper employs an improved iterative self-organizing data analysis technique algorithm to generate typical scenarios consistent with the scheduling time scale. Quantile regression (QR) and Gaussian mixture model (GMM) clustering are utilized to generate typical scenarios for renewable energy output. Subsequently, considering operational constraints and equipment state constraints, a unified active–reactive power coordinated control model for the distribution network is established. Meanwhile, to ensure the optimality of the results, this paper adopts an improved northern goshawk optimization (NGO) algorithm to solve the model. Finally, the effectiveness and feasibility of the proposed method are validated and illustrated through an improved IEEE-33 bus test system tested on MATLAB 2024B. Through analysis, the proposed method can reduce the average voltage fluctuation by 6.72% and increase the renewable energy accommodation rate by up to 8.64%.
Open AccessCoordinated Control Strategy for Active–Reactive Power in High-Proportion Renewable Energy Distribution Networks with the Participation of Grid-Forming Energy Storage
The high proportion of renewable energy connected to the grid has resulted in insufficient consumption capacity in distribution networks, while the construction of new-type power distribution systems has imposed higher reliability requirements. With its flexible power synchronization control capabilities, grid-forming energy storage systems possess the ability to both promote the consumption of distributed energy resources in new-type distribution networks and enhance their reliability. However, current control methods are still hindered by drawbacks such as high computational complexity and a singular optimization objective. To address this, this paper proposes an optimized strategy for unified active–reactive power coordinated control in high-proportion renewable energy distribution networks with the participation of multiple grid-forming energy storage systems. Firstly, to optimize the parameters of grid-forming energy storage systems more accurately, this paper employs an improved iterative self-organizing data analysis technique algorithm to generate typical scenarios consistent with the scheduling time scale. Quantile regression (QR) and Gaussian mixture model (GMM) clustering are utilized to generate typical scenarios for renewable energy output. Subsequently, considering operational constraints and equipment state constraints, a unified active–reactive power coordinated control model for the distribution network is established. Meanwhile, to ensure the optimality of the results, this paper adopts an improved northern goshawk optimization (NGO) algorithm to solve the model. Finally, the effectiveness and feasibility of the proposed method are validated and illustrated through an improved IEEE-33 bus test system tested on MATLAB 2024B. Through analysis, the proposed method can reduce the average voltage fluctuation by 6.72% and increase the renewable energy accommodation rate by up to 8.64%.