Sarah Pletcher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sarah Pletcher has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Ngoc-Anh Nguyen
Center for Connected Care, Innovation & Implementation—Research, Houston Methodist Hospital, Houston, TX 77030, USA
5 shared publications - Grace Lee
Center for Connected Care, Innovation & Implementation—Research, Houston Methodist Hospital, Houston, TX 77030, USA
4 shared publications - Brendan M. Holderread
Center for Innovation, Houston Methodist, Houston, US
3 shared publications - Roberta Schwartz
Houston Methodist Academic Institute, Houston Methodist Hospital, Houston, TX 77030, USA
3 shared publications - Terrie Holman
Center for Innovation, Houston Methodist, Houston, US
2 shared publications - Courtenay R. Bruce
System Patient Experience, Houston Methodist System, Houston, TX 77030, USA
1 shared publication
Latest Publications
- Open Access
- 27 June 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (7) , 283
Implementation of Image-Based Artificial Intelligence Is Associated with Increased Case Volume in a High-Acuity, 15-Room Cardiothoracic Operating Suite at a Tertiary Academic Hospital
Background: Operating rooms generate substantial visual data that is rarely captured systematically. Image-based AI (IBAI) systems using computer vision offer a new approach to real-time perioperative workflow monitoring, but evidence of their impact on surgical case volume remains limited. The aim of this study was to evaluate the association between deployment of an IBAI system and monthly surgical case volume in a high-acuity cardiothoracic operating suite, using synthetic control with difference-in-differences estimation. Methods: We deployed an IBAI system with wall-mounted cameras and a YOLO-based (You Only Look Once) object detection model coupled with a transformer-based event detector in a 15-room cardiothoracic suite at Houston Methodist Hospital (HMH), the tertiary academic hospital of Houston Methodist health system. The deployment was conducted under an IRB-determined quality improvement framework with patient consent for ambient video capture, defined retention limits, and restricted access to recordings. Over a 16-month period spanning 6 months pre-deployment and 10 months post-deployment, the system monitored 5417 surgical cases and automatically detected additional perioperative events including patient entry, draping, and room turnover. Using a synthetic control methodology, we compared post-deployment outcomes at the intervention site against a weighted combination drawn from a pool of 11 Houston Methodist sites that did not yet implement IBAI (116,098 cases across the comparison sites; 121,515 cases in the full analytic dataset). Results: The synthetic control analysis with difference-in-differences estimation showed a statistically significant increase of approximately 25 cases per month (95% CI 8.3 to 41.0; p < 0.01; Bonferroni-adjusted p < 0.05), corresponding to a 7% increase in monthly case volume relative to baseline. Conclusions: Our findings suggest that IBAI can meaningfully improve OR efficiency and support data-driven perioperative management. Future work should evaluate whether case volume gains generalize across other surgical specialties, assess changes in operational outcomes such as turnover time and first-case on-time starts, and examine clinicians’ perceptions of IBAI.
- 27 June 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (7) , 283
Open AccessImplementation of Image-Based Artificial Intelligence Is Associated with Increased Case Volume in a High-Acuity, 15-Room Cardiothoracic Operating Suite at a Tertiary Academic Hospital
Background: Operating rooms generate substantial visual data that is rarely captured systematically. Image-based AI (IBAI) systems using computer vision offer a new approach to real-time perioperative workflow monitoring, but evidence of their impact on surgical case volume remains limited. The aim of this study was to evaluate the association between deployment of an IBAI system and monthly surgical case volume in a high-acuity cardiothoracic operating suite, using synthetic control with difference-in-differences estimation. Methods: We deployed an IBAI system with wall-mounted cameras and a YOLO-based (You Only Look Once) object detection model coupled with a transformer-based event detector in a 15-room cardiothoracic suite at Houston Methodist Hospital (HMH), the tertiary academic hospital of Houston Methodist health system. The deployment was conducted under an IRB-determined quality improvement framework with patient consent for ambient video capture, defined retention limits, and restricted access to recordings. Over a 16-month period spanning 6 months pre-deployment and 10 months post-deployment, the system monitored 5417 surgical cases and automatically detected additional perioperative events including patient entry, draping, and room turnover. Using a synthetic control methodology, we compared post-deployment outcomes at the intervention site against a weighted combination drawn from a pool of 11 Houston Methodist sites that did not yet implement IBAI (116,098 cases across the comparison sites; 121,515 cases in the full analytic dataset). Results: The synthetic control analysis with difference-in-differences estimation showed a statistically significant increase of approximately 25 cases per month (95% CI 8.3 to 41.0; p < 0.01; Bonferroni-adjusted p < 0.05), corresponding to a 7% increase in monthly case volume relative to baseline. Conclusions: Our findings suggest that IBAI can meaningfully improve OR efficiency and support data-driven perioperative management. Future work should evaluate whether case volume gains generalize across other surgical specialties, assess changes in operational outcomes such as turnover time and first-case on-time starts, and examine clinicians’ perceptions of IBAI.
- Open Access
- 26 January 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e78216
Scaling Wireless Continuous Vital Sign Monitoring Across an 8-Hospital Health System: Digital Health Implementation Report
Background: Frequent vital sign (VS) monitoring is central to inpatient safety but is traditionally performed manually every 4 hours, a century-old practice that can miss early clinical deterioration, disrupt patient sleep, and impose a heavy documentation burden on nursing staff. Continuous VS monitoring (CVSM) using wearable remote patient monitoring devices enables near real-time, high-frequency VS measurement while reducing manual workload and preserving patient rest. Objective: This implementation report describes the large-scale implementation of CVSM across an 8-hospital health system. The initiative aimed to (1) enhance earlier detection of patient health deterioration through continuous, algorithm-driven monitoring; (2) improve nursing workflow efficiency by reducing reliance on manual VS checks; and (3) minimize nighttime disruptions to support patient rest and recovery. Methods: The program was designed for system-wide scalability and executed from 2022 to 2024 using a 4-phase framework: strategic program design, program planning, go-live preparation, and implementation and optimization. A Food and Drug Administration–cleared wearable device (BioButton) continuously measured heart rate, respiratory rate, and skin temperature, with data integrated into Epic and monitored 24×7 through a centralized virtual operations center. Rollout followed a staggered playbook across approximately 2700 adult non–intensive care unit beds and was supported by leadership engagement, supply chain readiness, staff training, and phased superuser-led adoption. Implementation (Results): All 8 hospitals achieved full deployment between April 2023 and February 2024, with more than 95% device use rates and 100% nursing staff training completion. A standardized escalation workflow filtered approximately 50% of the alerts at the virtual operations center review stage, substantially reducing frontline alert burden. Operational refinements included revised heart rate and respiratory rate alert thresholds and the removal of temperature as a single alert trigger. Several units extended overnight manual VS intervals from every 4 hours to every 6 to 8 hours, with staff estimating approximately 4 hours saved per nursing shift. Patient care assistants redirected time toward patient mobility and personal care needs, while staff reported growing confidence in device performance over time. Conclusions: This initiative represents the first system-wide deployment of CVSM across a diverse, multihospital health system. Success was enabled by early strategic alignment, phased rollout, robust IT and monitoring infrastructure, and iterative optimization. The program demonstrates the feasibility of embedding CVSM into routine inpatient care to improve efficiency and patient experience. Transferable strategies, including phased rollouts, centralized monitoring, and structured change management, may inform other health systems pursuing digital VS redesign. Future work should rigorously evaluate impacts on patient outcomes, cost-effectiveness, and applicability to postacute and ambulatory care settings.
- 26 January 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e78216
Open AccessScaling Wireless Continuous Vital Sign Monitoring Across an 8-Hospital Health System: Digital Health Implementation Report
Background: Frequent vital sign (VS) monitoring is central to inpatient safety but is traditionally performed manually every 4 hours, a century-old practice that can miss early clinical deterioration, disrupt patient sleep, and impose a heavy documentation burden on nursing staff. Continuous VS monitoring (CVSM) using wearable remote patient monitoring devices enables near real-time, high-frequency VS measurement while reducing manual workload and preserving patient rest. Objective: This implementation report describes the large-scale implementation of CVSM across an 8-hospital health system. The initiative aimed to (1) enhance earlier detection of patient health deterioration through continuous, algorithm-driven monitoring; (2) improve nursing workflow efficiency by reducing reliance on manual VS checks; and (3) minimize nighttime disruptions to support patient rest and recovery. Methods: The program was designed for system-wide scalability and executed from 2022 to 2024 using a 4-phase framework: strategic program design, program planning, go-live preparation, and implementation and optimization. A Food and Drug Administration–cleared wearable device (BioButton) continuously measured heart rate, respiratory rate, and skin temperature, with data integrated into Epic and monitored 24×7 through a centralized virtual operations center. Rollout followed a staggered playbook across approximately 2700 adult non–intensive care unit beds and was supported by leadership engagement, supply chain readiness, staff training, and phased superuser-led adoption. Implementation (Results): All 8 hospitals achieved full deployment between April 2023 and February 2024, with more than 95% device use rates and 100% nursing staff training completion. A standardized escalation workflow filtered approximately 50% of the alerts at the virtual operations center review stage, substantially reducing frontline alert burden. Operational refinements included revised heart rate and respiratory rate alert thresholds and the removal of temperature as a single alert trigger. Several units extended overnight manual VS intervals from every 4 hours to every 6 to 8 hours, with staff estimating approximately 4 hours saved per nursing shift. Patient care assistants redirected time toward patient mobility and personal care needs, while staff reported growing confidence in device performance over time. Conclusions: This initiative represents the first system-wide deployment of CVSM across a diverse, multihospital health system. Success was enabled by early strategic alignment, phased rollout, robust IT and monitoring infrastructure, and iterative optimization. The program demonstrates the feasibility of embedding CVSM into routine inpatient care to improve efficiency and patient experience. Transferable strategies, including phased rollouts, centralized monitoring, and structured change management, may inform other health systems pursuing digital VS redesign. Future work should rigorously evaluate impacts on patient outcomes, cost-effectiveness, and applicability to postacute and ambulatory care settings.
- Open Access
- 29 October 2025
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 13, e77973
Implementation and Evaluation of a Virtual Transitional Care Intervention Using Automated Text Messaging and Virtual Visits After Emergency Department Discharges: Retrospective Cohort Study
Background: Emergency department (ED) overcrowding and avoidable revisits challenge health systems, with approximately 20% of patients returning within 30 days. ED-based transitional care interventions, including automated SMS text messaging, offer scalable, cost-effective means to improve follow-up, though evidence remains limited. Objective: This study evaluated a transitional care intervention combining SMS text messaging and virtual transitional care visits to reduce ED revisits and improve outpatient follow-up. Methods: This retrospective observational cohort study included patients discharged from 4 EDs within a single US health system between September 2023 and September 2024. Patients were categorized into two groups based on intervention engagements: (1) completed (requested, scheduled, and completed a visit) and (2) noncompleted (requested, scheduled, and did not complete). The primary outcome was spontaneous, unplanned ED revisits within 90 days; secondary outcomes included outpatient follow-up and time to first outpatient evaluation. Between-group differences were assessed using descriptive statistics and multivariable regression models (with P <.05 considered statistically significant). Results: Of 68,115 discharged patients, 42.72% (29,100/68,115) received an automated SMS text messaging for the virtual transitional care program, and 2.93% (853/29,100) accessed the scheduling link. Of these, 56.5% (482/853) requested a visit, 49.8% (240/482) scheduled, and 70% (168/240) completed the visit (completed group). Among 72 noncompleted patients, 57% (n=41) did not show, 32% (n=23) canceled, and 11% (n=8) scheduled 2 appointments but completed neither. Nearly half (35/72, 49%) of the noncompleted group had a subsequent ambulatory follow-up. Demographics, comorbidities, and acuity were similar. The noncompleted group was nearly twice as likely to return to the ED within 90 days (21/72, 29% vs 28/150 18.7%; χ 2 1 =4.20, P =.04; odds ratio 2.11, 95% CI 1.02‐4.33), while the completed group was more likely to complete outpatient follow-up (35/72, 49% vs 51/168, 30.4%; χ 2 1 =6.60, P =.01; odds ratio 2.15, 95% CI 1.03‐4.77). Time to first outpatient visit did not differ significantly between groups (mean 15.7, SD 19.0 d vs mean 19.8, SD 20.7 d; Δβ=–1.93, 95% CI –10.09 to 6.42; P =.65). Conclusions: A combined SMS text messaging and virtual transitional care program lowered 90-day ED revisits and increased outpatient follow-up, but engagement was low (2.9%). Future work should focus on optimizing care delivery and developing strategies to expand reach across the broader ED discharge population.
- 29 October 2025
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 13, e77973
Open AccessImplementation and Evaluation of a Virtual Transitional Care Intervention Using Automated Text Messaging and Virtual Visits After Emergency Department Discharges: Retrospective Cohort Study
Background: Emergency department (ED) overcrowding and avoidable revisits challenge health systems, with approximately 20% of patients returning within 30 days. ED-based transitional care interventions, including automated SMS text messaging, offer scalable, cost-effective means to improve follow-up, though evidence remains limited. Objective: This study evaluated a transitional care intervention combining SMS text messaging and virtual transitional care visits to reduce ED revisits and improve outpatient follow-up. Methods: This retrospective observational cohort study included patients discharged from 4 EDs within a single US health system between September 2023 and September 2024. Patients were categorized into two groups based on intervention engagements: (1) completed (requested, scheduled, and completed a visit) and (2) noncompleted (requested, scheduled, and did not complete). The primary outcome was spontaneous, unplanned ED revisits within 90 days; secondary outcomes included outpatient follow-up and time to first outpatient evaluation. Between-group differences were assessed using descriptive statistics and multivariable regression models (with P <.05 considered statistically significant). Results: Of 68,115 discharged patients, 42.72% (29,100/68,115) received an automated SMS text messaging for the virtual transitional care program, and 2.93% (853/29,100) accessed the scheduling link. Of these, 56.5% (482/853) requested a visit, 49.8% (240/482) scheduled, and 70% (168/240) completed the visit (completed group). Among 72 noncompleted patients, 57% (n=41) did not show, 32% (n=23) canceled, and 11% (n=8) scheduled 2 appointments but completed neither. Nearly half (35/72, 49%) of the noncompleted group had a subsequent ambulatory follow-up. Demographics, comorbidities, and acuity were similar. The noncompleted group was nearly twice as likely to return to the ED within 90 days (21/72, 29% vs 28/150 18.7%; χ 2 1 =4.20, P =.04; odds ratio 2.11, 95% CI 1.02‐4.33), while the completed group was more likely to complete outpatient follow-up (35/72, 49% vs 51/168, 30.4%; χ 2 1 =6.60, P =.01; odds ratio 2.15, 95% CI 1.03‐4.77). Time to first outpatient visit did not differ significantly between groups (mean 15.7, SD 19.0 d vs mean 19.8, SD 20.7 d; Δβ=–1.93, 95% CI –10.09 to 6.42; P =.65). Conclusions: A combined SMS text messaging and virtual transitional care program lowered 90-day ED revisits and increased outpatient follow-up, but engagement was low (2.9%). Future work should focus on optimizing care delivery and developing strategies to expand reach across the broader ED discharge population.
- Open Access
- 21 October 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (20) , 7434
Implementation of Remote Patient Monitoring and Earlier CERT Activation: Effects on ICU Transfer and Mortality
Introduction: Timely detection of clinical deterioration in hospitalized patients remains a challenge, often limited by intermittent vital signs (VS) monitoring and delayed escalation. Remote patient monitoring (RPM) offers a medium of high-frequency surveillance of patient VS and may facilitate earlier recognition of deterioration. This study evaluated whether RPM integration into rapid response workflows improves clinical outcomes among patients requiring clinical emergency response team (CERT) activation and subsequent intensive care unit (ICU) transfer. Methods: A retrospective study was conducted to assess the impact of RPM implementation on severity of illness and mortality in adult patients who experienced CERT activation followed by ICU transfer. The primary outcomes were severity of illness at ICU admission and in-hospital mortality. We hypothesized that patients in the post-intervention group would demonstrate better outcomes compared to pre-intervention. Results: A total of 1120 patients were included (PRE: n = 656; POST: n = 464). The POST group, which received continuous monitoring via the BioButton® device and augmented workflows, demonstrated a lower mean APACHE-IV score at ICU transfer (83.96 vs. 90.01; p = 0.0016 and reduced in-hospital mortality (7.75% vs. 11.48%; p = 0.084). Median ICU stay in the PRE group was 5.85 (3.00–11.58) and 5.07 (2.59–9.22) in the POST group (p: 0.0565). Total LOS was 11.95 (6.57–20.40) and 10.50 (6.01–18.17), respectively [p = 0.0278]. Conclusions: Integration of RPM into hospital care pathways was associated with earlier recognition of clinical deterioration, reduced illness severity at ICU admission, and lower in-hospital mortality. These findings may support the utility of RPM as part of a comprehensive, multicomponent, rapid response model to recognize early physiological deterioration and may improve patient safety and outcomes in acute care settings.
- 21 October 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (20) , 7434
Open AccessImplementation of Remote Patient Monitoring and Earlier CERT Activation: Effects on ICU Transfer and Mortality
Introduction: Timely detection of clinical deterioration in hospitalized patients remains a challenge, often limited by intermittent vital signs (VS) monitoring and delayed escalation. Remote patient monitoring (RPM) offers a medium of high-frequency surveillance of patient VS and may facilitate earlier recognition of deterioration. This study evaluated whether RPM integration into rapid response workflows improves clinical outcomes among patients requiring clinical emergency response team (CERT) activation and subsequent intensive care unit (ICU) transfer. Methods: A retrospective study was conducted to assess the impact of RPM implementation on severity of illness and mortality in adult patients who experienced CERT activation followed by ICU transfer. The primary outcomes were severity of illness at ICU admission and in-hospital mortality. We hypothesized that patients in the post-intervention group would demonstrate better outcomes compared to pre-intervention. Results: A total of 1120 patients were included (PRE: n = 656; POST: n = 464). The POST group, which received continuous monitoring via the BioButton® device and augmented workflows, demonstrated a lower mean APACHE-IV score at ICU transfer (83.96 vs. 90.01; p = 0.0016 and reduced in-hospital mortality (7.75% vs. 11.48%; p = 0.084). Median ICU stay in the PRE group was 5.85 (3.00–11.58) and 5.07 (2.59–9.22) in the POST group (p: 0.0565). Total LOS was 11.95 (6.57–20.40) and 10.50 (6.01–18.17), respectively [p = 0.0278]. Conclusions: Integration of RPM into hospital care pathways was associated with earlier recognition of clinical deterioration, reduced illness severity at ICU admission, and lower in-hospital mortality. These findings may support the utility of RPM as part of a comprehensive, multicomponent, rapid response model to recognize early physiological deterioration and may improve patient safety and outcomes in acute care settings.
- Open Access
- 29 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Scaling Wireless Continuous Vital Sign Monitoring Across an 8-Hospital Health System: Digital Health Implementation Report (Preprint)
BACKGROUND Frequent vital sign (VS) monitoring is central to inpatient safety but is traditionally performed manually every 4 hours, a century-old practice that can miss early clinical deterioration, disrupt patient sleep, and impose a heavy documentation burden on nursing staff. Continuous VS monitoring (CVSM) using wearable remote patient monitoring devices enables near real-time, high-frequency VS measurement while reducing manual workload and preserving patient rest. OBJECTIVE This implementation report describes the large-scale implementation of CVSM across an 8-hospital health system. The initiative aimed to (1) enhance earlier detection of patient health deterioration through continuous, algorithm-driven monitoring; (2) improve nursing workflow efficiency by reducing reliance on manual VS checks; and (3) minimize nighttime disruptions to support patient rest and recovery. METHODS The program was designed for system-wide scalability and executed from 2022 to 2024 using a 4-phase framework: strategic program design, program planning, go-live preparation, and implementation and optimization. A Food and Drug Administration–cleared wearable device (BioButton) continuously measured heart rate, respiratory rate, and skin temperature, with data integrated into Epic and monitored 24×7 through a centralized virtual operations center. Rollout followed a staggered playbook across approximately 2700 adult non–intensive care unit beds and was supported by leadership engagement, supply chain readiness, staff training, and phased superuser-led adoption. RESULTS All 8 hospitals achieved full deployment between April 2023 and February 2024, with more than 95% device use rates and 100% nursing staff training completion. A standardized escalation workflow filtered approximately 50% of the alerts at the virtual operations center review stage, substantially reducing frontline alert burden. Operational refinements included revised heart rate and respiratory rate alert thresholds and the removal of temperature as a single alert trigger. Several units extended overnight manual VS intervals from every 4 hours to every 6 to 8 hours, with staff estimating approximately 4 hours saved per nursing shift. Patient care assistants redirected time toward patient mobility and personal care needs, while staff reported growing confidence in device performance over time. CONCLUSIONS This initiative represents the first system-wide deployment of CVSM across a diverse, multihospital health system. Success was enabled by early strategic alignment, phased rollout, robust IT and monitoring infrastructure, and iterative optimization. The program demonstrates the feasibility of embedding CVSM into routine inpatient care to improve efficiency and patient experience. Transferable strategies, including phased rollouts, centralized monitoring, and structured change management, may inform other health systems pursuing digital VS redesign. Future work should rigorously evaluate impacts on patient outcomes, cost-effectiveness, and applicability to postacute and ambulatory care settings.
- 29 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessScaling Wireless Continuous Vital Sign Monitoring Across an 8-Hospital Health System: Digital Health Implementation Report (Preprint)
BACKGROUND Frequent vital sign (VS) monitoring is central to inpatient safety but is traditionally performed manually every 4 hours, a century-old practice that can miss early clinical deterioration, disrupt patient sleep, and impose a heavy documentation burden on nursing staff. Continuous VS monitoring (CVSM) using wearable remote patient monitoring devices enables near real-time, high-frequency VS measurement while reducing manual workload and preserving patient rest. OBJECTIVE This implementation report describes the large-scale implementation of CVSM across an 8-hospital health system. The initiative aimed to (1) enhance earlier detection of patient health deterioration through continuous, algorithm-driven monitoring; (2) improve nursing workflow efficiency by reducing reliance on manual VS checks; and (3) minimize nighttime disruptions to support patient rest and recovery. METHODS The program was designed for system-wide scalability and executed from 2022 to 2024 using a 4-phase framework: strategic program design, program planning, go-live preparation, and implementation and optimization. A Food and Drug Administration–cleared wearable device (BioButton) continuously measured heart rate, respiratory rate, and skin temperature, with data integrated into Epic and monitored 24×7 through a centralized virtual operations center. Rollout followed a staggered playbook across approximately 2700 adult non–intensive care unit beds and was supported by leadership engagement, supply chain readiness, staff training, and phased superuser-led adoption. RESULTS All 8 hospitals achieved full deployment between April 2023 and February 2024, with more than 95% device use rates and 100% nursing staff training completion. A standardized escalation workflow filtered approximately 50% of the alerts at the virtual operations center review stage, substantially reducing frontline alert burden. Operational refinements included revised heart rate and respiratory rate alert thresholds and the removal of temperature as a single alert trigger. Several units extended overnight manual VS intervals from every 4 hours to every 6 to 8 hours, with staff estimating approximately 4 hours saved per nursing shift. Patient care assistants redirected time toward patient mobility and personal care needs, while staff reported growing confidence in device performance over time. CONCLUSIONS This initiative represents the first system-wide deployment of CVSM across a diverse, multihospital health system. Success was enabled by early strategic alignment, phased rollout, robust IT and monitoring infrastructure, and iterative optimization. The program demonstrates the feasibility of embedding CVSM into routine inpatient care to improve efficiency and patient experience. Transferable strategies, including phased rollouts, centralized monitoring, and structured change management, may inform other health systems pursuing digital VS redesign. Future work should rigorously evaluate impacts on patient outcomes, cost-effectiveness, and applicability to postacute and ambulatory care settings.