Urooj Abid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Urooj Abid has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hafiz Zia Ur Rehman
Department of Biomedical and Mechatronics Engineering, Air University, Islamabad, Pakistan
2 shared publications Hammad Nazeer
1 shared publication- Hammad Nazeer
Department of Mechatronics Engineering, Air University, Islamabad, Pakistan
1 shared publication - Husam A. Neamah
University of Debrecen
1 shared publication - Jamila Akhter
Air University Islamabad, Neuroimaging Research Group, Mechatronics and Biomedical Engineering Department, Islamabad, Pakistan
1 shared publication - Muhammad Tallal Saeed
Department of Mechatronics and Biomedical Engineering, Air University, Islamabad 44000, Pakistan
1 shared publication
Latest Publications
- 30 August 2026
- Published by Wiley in International Journal of Imaging Systems and Technology
- Vol. 36 (5) , e70437
Enhancing fNIRS ‐Based Decoding: A Heterogeneous Ensemble Network for Six‐Class Movement Classification
Neurological upper‐limb impairments severely affect functional independence, motivating the development of brain‐computer interface (BCI) systems for decoding motor intention. Although functional near‐infrared spectroscopy (fNIRS) is a promising modality, its low signal‐to‐noise ratio and large inter‐subject variability make multi‐class motor decoding difficult. In this study, a Heterogeneous Controlled Temporal Ensemble Network (HCTE‐Net) is proposed to classify six different upper‐limb motor tasks based on fNIRS signals. Twenty healthy participants were included for the data acquisition from the motor cortex region of the brain and standardized hemodynamic modeling was used for pre‐processing of signals to include task‐related dynamics. HCTE‐Net combines temporal representations of LSTM, Bi‐LSTM, and Peephole LSTM by probabilistic ensemble fusion. Among conventional machine learning models, XGBoost achieved the highest average accuracy of 69.68%, outperforming SVM (39.09%), LR (37.64%), DT (36.87%), RF (48.54%), LDA (39.39%), and NB (34.58%). The proposed HCTE‐Net achieved a maximum accuracy of 95.46%, exceeding LSTM (84.35%), Bi‐LSTM (87.17%), and Peephole LSTM (73.58%). The results of statistical analysis revealed significant differences among all methods (F = 659.324, p = 4.234 × 10 −152 ), and Tukey's HSD test showed significant improvement ( p < 0.001). Experimental results demonstrate that HCTE‐Net consistently outperforms single models across multiple evaluation metrics.
- 30 August 2026
- Published by Wiley in International Journal of Imaging Systems and Technology
- Vol. 36 (5) , e70437
Enhancing fNIRS ‐Based Decoding: A Heterogeneous Ensemble Network for Six‐Class Movement Classification
Neurological upper‐limb impairments severely affect functional independence, motivating the development of brain‐computer interface (BCI) systems for decoding motor intention. Although functional near‐infrared spectroscopy (fNIRS) is a promising modality, its low signal‐to‐noise ratio and large inter‐subject variability make multi‐class motor decoding difficult. In this study, a Heterogeneous Controlled Temporal Ensemble Network (HCTE‐Net) is proposed to classify six different upper‐limb motor tasks based on fNIRS signals. Twenty healthy participants were included for the data acquisition from the motor cortex region of the brain and standardized hemodynamic modeling was used for pre‐processing of signals to include task‐related dynamics. HCTE‐Net combines temporal representations of LSTM, Bi‐LSTM, and Peephole LSTM by probabilistic ensemble fusion. Among conventional machine learning models, XGBoost achieved the highest average accuracy of 69.68%, outperforming SVM (39.09%), LR (37.64%), DT (36.87%), RF (48.54%), LDA (39.39%), and NB (34.58%). The proposed HCTE‐Net achieved a maximum accuracy of 95.46%, exceeding LSTM (84.35%), Bi‐LSTM (87.17%), and Peephole LSTM (73.58%). The results of statistical analysis revealed significant differences among all methods (F = 659.324, p = 4.234 × 10 −152 ), and Tukey's HSD test showed significant improvement ( p < 0.001). Experimental results demonstrate that HCTE‐Net consistently outperforms single models across multiple evaluation metrics.
- Open Access
- 16 July 2026
- Published by Elsevier in Results in Control and Optimization
- Vol. 24
Enhancing classification accuracy for hand opening and closing using hybrid sEMG and fNIRS feature fusion
- 16 July 2026
- Published by Elsevier in Results in Control and Optimization
- Vol. 24
Open AccessEnhancing classification accuracy for hand opening and closing using hybrid sEMG and fNIRS feature fusion
- Open Access
Modeling and Simulation of Lower Limb Rehabilitation Exoskeletons: A Comparative Analysis for Dynamic Model Validation and Optimal Approach Selection
Accurate modeling and simulation of lower limb rehabilitation exoskeleton (LLRE) enables effective control resulting in enhanced performance and ensuring efficient rehabilitation. There are two primary objectives of this study. First is to validate the existing models and second is to identify the optimal modeling approach for exoskeletons. For validation, firstly a lower limb rehabilitation exoskeleton is modeled using three different modeling approaches which include analytical modeling, bond graph modeling, and modeling through Simscape (SS). Thereafter, dynamic responses of analytical and graphical modeling are compared with SS model using key dynamic response parameters, including rise time, peak time, and others. The SS-based physical model can be employed for validation because SS, unlike mathematical modeling, uses unit-consistent physical domain data and, therefore, serves as an intermediate step between mathematical modeling and hardware validation. Secondly, to identify the most suitable modeling approach, a structured and comprehensive comparison of different modeling approaches based on aspects such as control domain, complexity, ease of use, and other relevant factors is carried out. The results highlight the qualitative strengths and limitations of the three approaches. Previous studies focus on individual methods and lack such comparison. This work contributes to the validation of models and identification of an efficient and effective modeling methodology for LLRE. The findings reveal that Simscape™ is the most suitable approach for modeling LLREs as it provides multidisciplinary system modeling and supports real-time simulation. The validated model can now be employed for advancements in model-based control design. Moreover, the identified optimal approach provides an insight to researchers and engineers for model selection in early-stage design and control development of complex mechatronic systems. Future work includes comparison of dynamic responses with actual hardware responses to experimentally validate the effectiveness of the model for real-world patient assistance and mobility restoration.
Open AccessModeling and Simulation of Lower Limb Rehabilitation Exoskeletons: A Comparative Analysis for Dynamic Model Validation and Optimal Approach Selection
Accurate modeling and simulation of lower limb rehabilitation exoskeleton (LLRE) enables effective control resulting in enhanced performance and ensuring efficient rehabilitation. There are two primary objectives of this study. First is to validate the existing models and second is to identify the optimal modeling approach for exoskeletons. For validation, firstly a lower limb rehabilitation exoskeleton is modeled using three different modeling approaches which include analytical modeling, bond graph modeling, and modeling through Simscape (SS). Thereafter, dynamic responses of analytical and graphical modeling are compared with SS model using key dynamic response parameters, including rise time, peak time, and others. The SS-based physical model can be employed for validation because SS, unlike mathematical modeling, uses unit-consistent physical domain data and, therefore, serves as an intermediate step between mathematical modeling and hardware validation. Secondly, to identify the most suitable modeling approach, a structured and comprehensive comparison of different modeling approaches based on aspects such as control domain, complexity, ease of use, and other relevant factors is carried out. The results highlight the qualitative strengths and limitations of the three approaches. Previous studies focus on individual methods and lack such comparison. This work contributes to the validation of models and identification of an efficient and effective modeling methodology for LLRE. The findings reveal that Simscape™ is the most suitable approach for modeling LLREs as it provides multidisciplinary system modeling and supports real-time simulation. The validated model can now be employed for advancements in model-based control design. Moreover, the identified optimal approach provides an insight to researchers and engineers for model selection in early-stage design and control development of complex mechatronic systems. Future work includes comparison of dynamic responses with actual hardware responses to experimentally validate the effectiveness of the model for real-world patient assistance and mobility restoration.