DongMin Park
Research Subjects
DongMin Park has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Dong Geon Lee
Department of Physical Therapy, Sinsegae Rehabilitation Hospital, Changwon 51216, Republic of Korea
2 shared publications - Kyeongbong Lee
Department of Physical Therapy, Kangwon National University, Samcheok, Republic of Korea
2 shared publications - Seung Heun An
Department of Gait Lab National Rehabilitation Center Seoul South Korea
2 shared publications
Latest Publications
- Open Access
- 6 December 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (24) , 8649
Predictors of Independent Community Ambulation in Individuals with Chronic Stroke: A Cross-Sectional Study of Gait Speed, Gait Endurance, and Balance Self-Efficacy
Background/Objectives: Community ambulation after stroke depends on locomotor capacity and confidence in everyday environments. We compared functional performance across three community walking levels and identified constructs independently associated with being an independent community walker in individuals with chronic stroke. Methods: Adults admitted to an acute-care general hospital or an inpatient rehabilitation hospital were enrolled. Community walking level was classified by a self-reported questionnaire. Primary constructs were gait speed, gait endurance, and balance self-efficacy measured with standard clinical tests. Additional measures described balance, lower-limb motor function, and task-based mobility. Group differences were examined with one-way analysis of variance with Bonferroni comparisons. Community walking status was modeled with binary logistic regression using forward stepwise selection. Results: Fifty-nine individuals were analyzed. Performance differed across levels. Effect sizes were small, medium, or large overall. Independent community walkers showed faster gait speed, longer walking distance, and higher balance self-efficacy, with the same direction for balance and lower-limb motor scores and shorter times on task-based tests. In univariable models, age, sex, and time since stroke were not associated with independence, whereas assistive device use related to lower odds. In the multivariable model, gait speed, gait endurance, and balance self-efficacy retained independent associations with independent community walking. Other measures were not retained after adjustment. Conclusions: Community walking status in chronic stroke relates most closely to gait speed, gait endurance, and balance self-efficacy. Evaluation can emphasize the 10 m Walk Test, 6 Min Walk Test, and Activities-specific Balance Confidence Scale, with impairment and task-based tests used to guide intervention planning.
- 6 December 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (24) , 8649
Open AccessPredictors of Independent Community Ambulation in Individuals with Chronic Stroke: A Cross-Sectional Study of Gait Speed, Gait Endurance, and Balance Self-Efficacy
Background/Objectives: Community ambulation after stroke depends on locomotor capacity and confidence in everyday environments. We compared functional performance across three community walking levels and identified constructs independently associated with being an independent community walker in individuals with chronic stroke. Methods: Adults admitted to an acute-care general hospital or an inpatient rehabilitation hospital were enrolled. Community walking level was classified by a self-reported questionnaire. Primary constructs were gait speed, gait endurance, and balance self-efficacy measured with standard clinical tests. Additional measures described balance, lower-limb motor function, and task-based mobility. Group differences were examined with one-way analysis of variance with Bonferroni comparisons. Community walking status was modeled with binary logistic regression using forward stepwise selection. Results: Fifty-nine individuals were analyzed. Performance differed across levels. Effect sizes were small, medium, or large overall. Independent community walkers showed faster gait speed, longer walking distance, and higher balance self-efficacy, with the same direction for balance and lower-limb motor scores and shorter times on task-based tests. In univariable models, age, sex, and time since stroke were not associated with independence, whereas assistive device use related to lower odds. In the multivariable model, gait speed, gait endurance, and balance self-efficacy retained independent associations with independent community walking. Other measures were not retained after adjustment. Conclusions: Community walking status in chronic stroke relates most closely to gait speed, gait endurance, and balance self-efficacy. Evaluation can emphasize the 10 m Walk Test, 6 Min Walk Test, and Activities-specific Balance Confidence Scale, with impairment and task-based tests used to guide intervention planning.
- Open Access
- 17 October 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (20) , 7358
Differences in Functional Performance and Minimal Detectable Change According to Levels of Ankle Plantar Flexor Spasticity in Patients with Chronic Stroke
Background/Objectives: Ankle plantar flexor spasticity after stroke may limit mobility, especially during turning and multi-directional stepping. Evidence on performance differences and measurement properties across spasticity levels is limited. We examined whether performance on the Activities-specific Balance Confidence Scale (ABC Scale), Five Times Sit-to-Stand Test (5xSTS), Figure-of-8 Walk Test (F8WT), and Four-Square Step Test (FSST) differs by spasticity severity, and evaluated test–retest reliability, the intraclass correlation coefficient (ICC), the standard error of measurement (SEM), and the minimal detectable change (MDC). Methods: In an observational cross-sectional comparative study, 54 individuals more than 6 months post-stroke were classified into three groups by the Modified Ashworth Scale (MAS = 0, MAS = 1 − 1+, MAS ≥ 2). Participants completed the ABC Scale, 5xSTS, F8WT, and FSST. One-way analysis of variance with Bonferroni adjustment tested group differences. Reliability was quantified using ICC (2,1); SEM and MDC at the 95% confidence level indexed absolute reliability. Results: No significant differences were found for the ABC Scale or 5xSTS. F8WT and FSST differed by spasticity level (p < 0.05), with poorer performance in the highest-spasticity group versus no spasticity. ICCs were high across assessments. All SEMs were <20% of test–retest means, and all MDCs were <20% of maximum scores. Conclusion: Assessments that require directional change detected differences across spasticity levels, whereas balance confidence and repeated sit-to-stand did not. All measures showed acceptable relative and absolute reliability. Findings support selecting outcomes by spasticity severity and using SEM and MDC as reference values when interpreting change in stroke rehabilitation.
- 17 October 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (20) , 7358
Open AccessDifferences in Functional Performance and Minimal Detectable Change According to Levels of Ankle Plantar Flexor Spasticity in Patients with Chronic Stroke
Background/Objectives: Ankle plantar flexor spasticity after stroke may limit mobility, especially during turning and multi-directional stepping. Evidence on performance differences and measurement properties across spasticity levels is limited. We examined whether performance on the Activities-specific Balance Confidence Scale (ABC Scale), Five Times Sit-to-Stand Test (5xSTS), Figure-of-8 Walk Test (F8WT), and Four-Square Step Test (FSST) differs by spasticity severity, and evaluated test–retest reliability, the intraclass correlation coefficient (ICC), the standard error of measurement (SEM), and the minimal detectable change (MDC). Methods: In an observational cross-sectional comparative study, 54 individuals more than 6 months post-stroke were classified into three groups by the Modified Ashworth Scale (MAS = 0, MAS = 1 − 1+, MAS ≥ 2). Participants completed the ABC Scale, 5xSTS, F8WT, and FSST. One-way analysis of variance with Bonferroni adjustment tested group differences. Reliability was quantified using ICC (2,1); SEM and MDC at the 95% confidence level indexed absolute reliability. Results: No significant differences were found for the ABC Scale or 5xSTS. F8WT and FSST differed by spasticity level (p < 0.05), with poorer performance in the highest-spasticity group versus no spasticity. ICCs were high across assessments. All SEMs were <20% of test–retest means, and all MDCs were <20% of maximum scores. Conclusion: Assessments that require directional change detected differences across spasticity levels, whereas balance confidence and repeated sit-to-stand did not. All measures showed acceptable relative and absolute reliability. Findings support selecting outcomes by spasticity severity and using SEM and MDC as reference values when interpreting change in stroke rehabilitation.