Diana Matilde Otero Vargas
Research Subjects
Diana Matilde Otero Vargas has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alexis Cortina Hernández1 shared publication
- Carlos Alberto Severiche Sierra
Universidad de Cartagena, Cartagena de Indias, Colombia
1 shared publication - Claudia Patricia Casas Patarroyo
Fundación Universitaria de Ciencias de la Salud
1 shared publication - Jheremy Reyes
Department of Hematology Los Cobos Medical Center El Bosque University Bogotá Colombia
1 shared publication - John Fredy Nieto-Ríos
Universidad de Antioquía
1 shared publication José Luis Timaná Arciniegas
Fundación Hospital San Pedro
1 shared publication
Latest Publications
- Open Access
- 30 November 2025
- Published by Asociacion Colombiana de Hematologia y Oncologia in Revista Colombiana de Hematología y Oncología
- Vol. 12 (2) , 126-140
Citometría de flujo en el diagnóstico y monitorización de pacientes con hemoglobinuria paroxística nocturna
Introduction: HPN is a clonal disease of hematopoietic stem cells, characterized by intravascular hemolysis, thrombotic episodes, risk of bone marrow failure, and damage to organs such as the kidney and lung. Mutations in the PIGA gene cause a deficiency of glycosylphosphatidylinositol (GPI)-anchored proteins, increasing cellular susceptibility to complement-mediated lysis. Given its variable clinical presentation, early diagnosis and continuous monitoring with flow cytometry (CF) are crucial for effective management. Objective: To describe the application of CF in the diagnosis and follow-up of patients with HPN, highlighting its usefulness, benefits, and limitations. Methods: A literature review was conducted in databases such as PubMed, Embase, Scopus, Web of Science, and Google Scholar of studies published between January 2000 and July 2024. Studies in humans that describe the use of CF in the diagnosis and monitoring of HPN were included. Results: 40 studies were selected. CF has high sensitivity and specificity (>95%) for detecting GPI-deficient cells using markers such as CD55 and CD59. CF was effective for quantifying clonal burden, monitoring response to anti-C5 treatment, and detecting complications such as thrombosis and myelodysplastic syndromes. Advanced CF techniques allowed for the identification of clones at low levels (<0.1%), facilitating timely clinical interventions. Conclusions: Flow cytometry supports the diagnosis and monitoring of HPN, improving disease management and optimizing treatment.
- 30 November 2025
- Published by Asociacion Colombiana de Hematologia y Oncologia in Revista Colombiana de Hematología y Oncología
- Vol. 12 (2) , 126-140
Open AccessCitometría de flujo en el diagnóstico y monitorización de pacientes con hemoglobinuria paroxística nocturna
Introduction: HPN is a clonal disease of hematopoietic stem cells, characterized by intravascular hemolysis, thrombotic episodes, risk of bone marrow failure, and damage to organs such as the kidney and lung. Mutations in the PIGA gene cause a deficiency of glycosylphosphatidylinositol (GPI)-anchored proteins, increasing cellular susceptibility to complement-mediated lysis. Given its variable clinical presentation, early diagnosis and continuous monitoring with flow cytometry (CF) are crucial for effective management. Objective: To describe the application of CF in the diagnosis and follow-up of patients with HPN, highlighting its usefulness, benefits, and limitations. Methods: A literature review was conducted in databases such as PubMed, Embase, Scopus, Web of Science, and Google Scholar of studies published between January 2000 and July 2024. Studies in humans that describe the use of CF in the diagnosis and monitoring of HPN were included. Results: 40 studies were selected. CF has high sensitivity and specificity (>95%) for detecting GPI-deficient cells using markers such as CD55 and CD59. CF was effective for quantifying clonal burden, monitoring response to anti-C5 treatment, and detecting complications such as thrombosis and myelodysplastic syndromes. Advanced CF techniques allowed for the identification of clones at low levels (<0.1%), facilitating timely clinical interventions. Conclusions: Flow cytometry supports the diagnosis and monitoring of HPN, improving disease management and optimizing treatment.
- Open Access
- 4 July 2025
- Published by Revista Científica Multidisciplinar G-ner@ndo in Revista Científica Multidisciplinar G-NER@NDO
- Vol. 6 (2)
Perception of hearing loss among call center workers in Barranquilla (Northern Colombia)
The perception of hearing loss and listening effort was investigated among call center agents in Barranquilla (2025), a high-demand, noisy environment. This was a cross-sectional observational study with convenience sampling. Fifty-five valid questionnaires from workers with ≥3 months of seniority and headphone use were analyzed. The instrument, adapted from the HHIA, QSHL, and a THI module, included 18 items (No/Sometimes/Yes) recoded 0–2 for a score of 0–36 (α=0.71). Frequencies and descriptive statistics were estimated. The mean score was 16.04 (SD=9.27); 85.5% had ≥1 affirmative response, and 20.0% reported tinnitus at the end of the shift. The highest proportions of “Yes” responses were observed for requests for repetitions, difficulty understanding with floor noise, anxiety under high workloads, and concern about performance and possible hearing impairment. This profile suggests speech intelligibility deficits in noise and high cognitive load with preserved clinical thresholds, consistent with listening effort frameworks and subclinical pathophysiology.
- 4 July 2025
- Published by Revista Científica Multidisciplinar G-ner@ndo in Revista Científica Multidisciplinar G-NER@NDO
- Vol. 6 (2)
Open AccessPerception of hearing loss among call center workers in Barranquilla (Northern Colombia)
The perception of hearing loss and listening effort was investigated among call center agents in Barranquilla (2025), a high-demand, noisy environment. This was a cross-sectional observational study with convenience sampling. Fifty-five valid questionnaires from workers with ≥3 months of seniority and headphone use were analyzed. The instrument, adapted from the HHIA, QSHL, and a THI module, included 18 items (No/Sometimes/Yes) recoded 0–2 for a score of 0–36 (α=0.71). Frequencies and descriptive statistics were estimated. The mean score was 16.04 (SD=9.27); 85.5% had ≥1 affirmative response, and 20.0% reported tinnitus at the end of the shift. The highest proportions of “Yes” responses were observed for requests for repetitions, difficulty understanding with floor noise, anxiety under high workloads, and concern about performance and possible hearing impairment. This profile suggests speech intelligibility deficits in noise and high cognitive load with preserved clinical thresholds, consistent with listening effort frameworks and subclinical pathophysiology.