DVDiana Matilde Otero Vargas

Diana Matilde Otero Vargas

*This is an algorithmically generated author record based on publicly available information.

Diana Matilde Otero Vargas has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Citometría de flujo en el diagnóstico y monitorización de pacientes con hemoglobinuria paroxística nocturna

    by Jheremy Reyes Castellanos, Liliana Paola Correa Pérez, John Fredy Nieto Ríos, Mauricio Andrés Alzate Arias, José Antonio Rojas Suárez, Mónica Patricia Londoño Barrera, Claudia Patricia Casas, Diana Otero de la Hoz, María Helena Zappa Jaimes, José Luis Timaná Arciniegas

    Introduction: HPN is a clonal disease of hematopoietic stem cells, characterized by intravascular hemolysis, thrombotic episodes, risk of bone marrow failure, and damage to organs such as the kidney and lung. Mutations in the PIGA gene cause a deficiency of glycosylphosphatidylinositol (GPI)-anchored proteins, increasing cellular susceptibility to complement-mediated lysis. Given its variable clinical presentation, early diagnosis and continuous monitoring with flow cytometry (CF) are crucial for effective management. Objective: To describe the application of CF in the diagnosis and follow-up of patients with HPN, highlighting its usefulness, benefits, and limitations. Methods: A literature review was conducted in databases such as PubMed, Embase, Scopus, Web of Science, and Google Scholar of studies published between January 2000 and July 2024. Studies in humans that describe the use of CF in the diagnosis and monitoring of HPN were included. Results: 40 studies were selected. CF has high sensitivity and specificity (>95%) for detecting GPI-deficient cells using markers such as CD55 and CD59. CF was effective for quantifying clonal burden, monitoring response to anti-C5 treatment, and detecting complications such as thrombosis and myelodysplastic syndromes. Advanced CF techniques allowed for the identification of clones at low levels (<0.1%), facilitating timely clinical interventions. Conclusions: Flow cytometry supports the diagnosis and monitoring of HPN, improving disease management and optimizing treatment.

  • Open Access

    Perception of hearing loss among call center workers in Barranquilla (Northern Colombia)

    by Diana Matilde Otero Vargas, Alexis Cortina Hernández, Karina Paola Buelvas Almanza, Carlos Alberto Severiche Sierra

    The perception of hearing loss and listening effort was investigated among call center agents in Barranquilla (2025), a high-demand, noisy environment. This was a cross-sectional observational study with convenience sampling. Fifty-five valid questionnaires from workers with ≥3 months of seniority and headphone use were analyzed. The instrument, adapted from the HHIA, QSHL, and a THI module, included 18 items (No/Sometimes/Yes) recoded 0–2 for a score of 0–36 (α=0.71). Frequencies and descriptive statistics were estimated. The mean score was 16.04 (SD=9.27); 85.5% had ≥1 affirmative response, and 20.0% reported tinnitus at the end of the shift. The highest proportions of “Yes” responses were observed for requests for repetitions, difficulty understanding with floor noise, anxiety under high workloads, and concern about performance and possible hearing impairment. This profile suggests speech intelligibility deficits in noise and high cognitive load with preserved clinical thresholds, consistent with listening effort frameworks and subclinical pathophysiology.