G. Srividhya
Research Subjects
G. Srividhya has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Alaudeen Km1 shared publication
Prasanna R
1 shared publication- Rajesh Kanna R.
Department of Computer Science and Engineering, SRM Institute of Science and Technology, Ramapuram, Chennai, India
1 shared publication S. Maheswari
Department of ECE Panimalar Engineering College, Poonamallee, Chennai, Tamil Nadu 600123, India
1 shared publication- Vinoth Manoharan
Department of Electronics and Communication Engineering, Saveetha School of Engineering, Saveetha University, Chennai, India
1 shared publication
Latest Publications
- Open Access
- 20 August 2026
- Published by Elsevier in SSRN Electronic Journal
A Wearable Arm-Band Device For Continuous Assessment Of Peripheral Endothelial Function Toward Early Detection Of Cardiovascular Diseases
Cardiovascular diseases (CVDs) are among the primary causes of mortality and there is a considerable need for easy and non-invasive modality for early risk assessment. Endothelial dysfunction is an early marker for cardiovascular abnormalities and assessing it an early stage can save crucial lives. Hence in this work, a novel non-invasive evaluation method, along with wearable arm-band prototype device to evaluate peripheral endothelial function, have been developed for the early detection of cardiovascular health problems. The proposed wearable system integrates a Qt-Py ESP32 microcontroller, MCP3422 analog front-end (AFE), NTC thermistor, and a rechargeable Li-ion battery within a compact arm-band platform. . The proposed evaluation method is based on thermal sensing wherein skin temperature variations are recorded during a hand exercise routine and the resulting skin temperature variations are correlated to peripheral blood flow variations. High-resolution AFE is used for digitization of collected sensor signals and ESP32 is used for feature extraction and analysis. A non-invasive assessment algorithm is applied to determine the quantity of endothelial function and deviations therein that could signal cardiovascular impairment. The proposed prototype is able to capture physiological change related to peripheral vascular function with good reliability demonstrated by experimental validation conducted on 100 individuals. Thus, the results obtained showed good prospects for applying these devices to early diagnosis of cardiovascular diseases, tele monitoring patients and preventive care. The wearable arm-band device, which is proposed to be a low cost, portable and easy-to-use solution, presents a potential opportunity for continuous assessment of cardiovascular health.
- 20 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Wearable Arm-Band Device For Continuous Assessment Of Peripheral Endothelial Function Toward Early Detection Of Cardiovascular Diseases
Cardiovascular diseases (CVDs) are among the primary causes of mortality and there is a considerable need for easy and non-invasive modality for early risk assessment. Endothelial dysfunction is an early marker for cardiovascular abnormalities and assessing it an early stage can save crucial lives. Hence in this work, a novel non-invasive evaluation method, along with wearable arm-band prototype device to evaluate peripheral endothelial function, have been developed for the early detection of cardiovascular health problems. The proposed wearable system integrates a Qt-Py ESP32 microcontroller, MCP3422 analog front-end (AFE), NTC thermistor, and a rechargeable Li-ion battery within a compact arm-band platform. . The proposed evaluation method is based on thermal sensing wherein skin temperature variations are recorded during a hand exercise routine and the resulting skin temperature variations are correlated to peripheral blood flow variations. High-resolution AFE is used for digitization of collected sensor signals and ESP32 is used for feature extraction and analysis. A non-invasive assessment algorithm is applied to determine the quantity of endothelial function and deviations therein that could signal cardiovascular impairment. The proposed prototype is able to capture physiological change related to peripheral vascular function with good reliability demonstrated by experimental validation conducted on 100 individuals. Thus, the results obtained showed good prospects for applying these devices to early diagnosis of cardiovascular diseases, tele monitoring patients and preventive care. The wearable arm-band device, which is proposed to be a low cost, portable and easy-to-use solution, presents a potential opportunity for continuous assessment of cardiovascular health.
- Open Access
- 30 June 2025
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- p. 541–549
Compact Single and Dual-Band Branch-Line Coupler with Effective Fractional Bandwidth for Wireless Communication Systems
Multiple wireless communication systems make use of a branch-line coupler (BLC), which is a passive microwave component. For the purpose of splitting and combining microwave signals, as well as providing a 90-degree phase shift between the output ports, this 4-port device is made from four quarter-wavelength (λ/4) transmission lines. Having recently developed a dual-band branch-line coupler (DBBLC), there has been a lot of attention paid to this development. When it comes to getting dual-band (DB) functioning of a BLC, one of the most common approaches is stub loaded transmission lines. For the BLC, stubs may be positioned either in the center of the arms or at the input of the arms. Stepped-impedance stubs, orthogonal coupled branches, and coupled lines are some of the strategies that have been shown to be effective in achieving DB functioning of a coupler. Through the utilization of the Elongated T-Shape Transmission Line (ETSTL), this work presents a one-of-a-kind design for each single-band branch-line coupler (SBBLC) and DBBLC that is of a compact proportion. Based on the information presented in this article, the SBBLC operates at a frequency of 0.9 GHz, whereas the DBBLC operates at 0.9 and 2.4 GHz. Using a fractional bandwidth (FBW) of 44%, the coupler that has been proposed is able to function at both 0.9 GHz (GSM) and 2.4 GHz (wireless). Efforts are done on reducing the size of the coupler to be ready forfabrication.
- 30 June 2025
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- p. 541–549
Open AccessCompact Single and Dual-Band Branch-Line Coupler with Effective Fractional Bandwidth for Wireless Communication Systems
Multiple wireless communication systems make use of a branch-line coupler (BLC), which is a passive microwave component. For the purpose of splitting and combining microwave signals, as well as providing a 90-degree phase shift between the output ports, this 4-port device is made from four quarter-wavelength (λ/4) transmission lines. Having recently developed a dual-band branch-line coupler (DBBLC), there has been a lot of attention paid to this development. When it comes to getting dual-band (DB) functioning of a BLC, one of the most common approaches is stub loaded transmission lines. For the BLC, stubs may be positioned either in the center of the arms or at the input of the arms. Stepped-impedance stubs, orthogonal coupled branches, and coupled lines are some of the strategies that have been shown to be effective in achieving DB functioning of a coupler. Through the utilization of the Elongated T-Shape Transmission Line (ETSTL), this work presents a one-of-a-kind design for each single-band branch-line coupler (SBBLC) and DBBLC that is of a compact proportion. Based on the information presented in this article, the SBBLC operates at a frequency of 0.9 GHz, whereas the DBBLC operates at 0.9 and 2.4 GHz. Using a fractional bandwidth (FBW) of 44%, the coupler that has been proposed is able to function at both 0.9 GHz (GSM) and 2.4 GHz (wireless). Efforts are done on reducing the size of the coupler to be ready forfabrication.