Ecaterina Pasat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ecaterina Pasat has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Daniela Bursacovschi
IMSP Institutul de Cardiologie
2 shared publications - Marcel Abras
Universitatea de Stat de Medicină şi Farmacie „Nicolae Testemiţanu
2 shared publications - Maria-Magdalena Vicol
Universitatea de Stat de Medicină și Farmacie “Nicolae Testemiţanu
2 shared publications - Artiom Surev
IMSP Institutul de Cardiologie
1 shared publication - Catalina Ciorici1 shared publication
Daniela Goian
Universitatea de Stat de Medicină și Farmacie “Nicolae Testemiţanu
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by Editorial Office "Bulletin of the Academy of Sciences of Moldova. Medical Sciences"
- Vol. 81 (1(81)) , 7-15
The efficacy of transcatheter treatment of aortic valve stenosis based on the type of implanted valve
Introduction. Aortic stenosis is the most common valvular disease among elderly patients and carries a poor prognosis if left untreated. Transcatheter aortic valve implantation (TAVI) has emerged as an effective alternative to surgical valve replacement, particularly in high- and intermediate-risk patients. The type of valve implanted may significantly influence postoperative outcomes. Aim of study. To assess the efficacy and safety of TAVI based on the type of prosthesis used: self-expanding (SEV) versus balloon-expandable (BEV). Materials and Methods. A prospective study was conducted on 114 patients over 70 years old with severe aortic stenosis who underwent TAVI: Abbott valve (n=44), Medtronic (n=40), Edwards (n=30). Valve performance and safety were evaluated according to Valve Academic Research Consortium-3 (VARC-3) criteria. Results. No significant differences were observed between groups regarding age, BMI, sex, or comorbidities. Edwards valves showed the highest post-TAVI mean pressure gradients (16.2 ± 6.7 mmHg), followed by Abbott (12.4 ± 6 mmHg) and Medtronic (10.1 ± 3.5 mmHg, pless than 0.001). Vmax was significantly higher in the Edwards group at all followups (pless than 0.01), indicating greater residual stenosis risk. Left ventricular function was similar across groups. Paravalvular regurgitation was more frequent with Edwards (pless than 0.001 vs. Abbott, p=0.008 vs. Medtronic). High-grade AV block and permanent pacemaker implantation were more frequent in the SEV group. Mortality and rehospitalization rates were similar between groups. Conclusions. TAVI proved to be an effective and safe treatment for severe aortic stenosis in elderly patients. The type of prosthesis influences hemodynamic performance and complication profile, highlighting the need for individualized valve selection based on patient characteristics.
- 1 October 2025
- Published by Editorial Office "Bulletin of the Academy of Sciences of Moldova. Medical Sciences"
- Vol. 81 (1(81)) , 7-15
Open AccessThe efficacy of transcatheter treatment of aortic valve stenosis based on the type of implanted valve
Introduction. Aortic stenosis is the most common valvular disease among elderly patients and carries a poor prognosis if left untreated. Transcatheter aortic valve implantation (TAVI) has emerged as an effective alternative to surgical valve replacement, particularly in high- and intermediate-risk patients. The type of valve implanted may significantly influence postoperative outcomes. Aim of study. To assess the efficacy and safety of TAVI based on the type of prosthesis used: self-expanding (SEV) versus balloon-expandable (BEV). Materials and Methods. A prospective study was conducted on 114 patients over 70 years old with severe aortic stenosis who underwent TAVI: Abbott valve (n=44), Medtronic (n=40), Edwards (n=30). Valve performance and safety were evaluated according to Valve Academic Research Consortium-3 (VARC-3) criteria. Results. No significant differences were observed between groups regarding age, BMI, sex, or comorbidities. Edwards valves showed the highest post-TAVI mean pressure gradients (16.2 ± 6.7 mmHg), followed by Abbott (12.4 ± 6 mmHg) and Medtronic (10.1 ± 3.5 mmHg, pless than 0.001). Vmax was significantly higher in the Edwards group at all followups (pless than 0.01), indicating greater residual stenosis risk. Left ventricular function was similar across groups. Paravalvular regurgitation was more frequent with Edwards (pless than 0.001 vs. Abbott, p=0.008 vs. Medtronic). High-grade AV block and permanent pacemaker implantation were more frequent in the SEV group. Mortality and rehospitalization rates were similar between groups. Conclusions. TAVI proved to be an effective and safe treatment for severe aortic stenosis in elderly patients. The type of prosthesis influences hemodynamic performance and complication profile, highlighting the need for individualized valve selection based on patient characteristics.
- 1 September 2025
- Published by Periodic Publication Moldovan Journal of Health Sciences in Moldovan Journal of Health Sciences
- Vol. 12 (3) , 27-33
Diastolic dysfunction and myocardial ischemia in TAVI patients
Introduction. Severe aortic stenosis and ischemic coronary artery disease are frequently associated in elderly patients, adding complexity to interventional management. Diastolic dysfunction, a marker of myocardial impairment and elevated filling pressures, may influence prognosis after transcatheter aortic valve implantation (TAVI), particularly in the presence of concomitant coronary pathology. The aim of the study was to analyze the interaction between severe aortic valve stenosis, left ventricular diastolic dysfunction, and coronary ischemia in elderly patients with complex cardiovascular disease. Material and methods. This was a prospective analytical cohort study including 85 patients treated between 2019 and 2023, divided into two groups: Group I - TAVI without coronary intervention (n = 56), and Group II - TAVI associated with percutaneous coronary intervention (PCI) (n = 29), consisting of patients with significant coronary lesions. Echocardiography was performed according to the ESC/EACVI 2016 guideline standards, with detailed assessment of diastolic function. Results. The prevalence of left ventricular diastolic dysfunction of varying severity showed a statistically significant difference between groups (p = 0.04): Group I - 35 patients (62.5%) versus Group II - 24 patients (82.7%). The E-wave velocity was lower in Group II: 152.4 cm/sec (IQR = 43.0) compared to 173.0 cm/sec (IQR = 32.0), p = 0.01. The E/A ratio and the incidence of E/A ≥2 showed a borderline significant difference (p = 0.04). Median E/e′ was higher in Group II - 9.2 (IQR = 5.4) compared to 6.4 (IQR = 4.2), p = 0.003. E/Vp was 1.2 (IQR = 0.4) versus 0.8 (IQR = 0.5), p less than 0.001. Diastolic dysfunction was more frequent in Group II, with significantly different echocardiographic parameters, including decreased E-wave velocity, increased E/e′ and E/Vp ratios, and a higher incidence of E/A ≥2. Conclusions. Patients undergoing both PCI and TAVI more frequently exhibited left ventricular diastolic dysfunction. The echocardiographic parameters E, E/e′, and E/Vp showed statistically significant differences, suggesting an additive impact of coronary artery disease on diastolic function impairment in the setting of severe aortic stenosis.
- 1 September 2025
- Published by Periodic Publication Moldovan Journal of Health Sciences in Moldovan Journal of Health Sciences
- Vol. 12 (3) , 27-33
Diastolic dysfunction and myocardial ischemia in TAVI patients
Introduction. Severe aortic stenosis and ischemic coronary artery disease are frequently associated in elderly patients, adding complexity to interventional management. Diastolic dysfunction, a marker of myocardial impairment and elevated filling pressures, may influence prognosis after transcatheter aortic valve implantation (TAVI), particularly in the presence of concomitant coronary pathology. The aim of the study was to analyze the interaction between severe aortic valve stenosis, left ventricular diastolic dysfunction, and coronary ischemia in elderly patients with complex cardiovascular disease. Material and methods. This was a prospective analytical cohort study including 85 patients treated between 2019 and 2023, divided into two groups: Group I - TAVI without coronary intervention (n = 56), and Group II - TAVI associated with percutaneous coronary intervention (PCI) (n = 29), consisting of patients with significant coronary lesions. Echocardiography was performed according to the ESC/EACVI 2016 guideline standards, with detailed assessment of diastolic function. Results. The prevalence of left ventricular diastolic dysfunction of varying severity showed a statistically significant difference between groups (p = 0.04): Group I - 35 patients (62.5%) versus Group II - 24 patients (82.7%). The E-wave velocity was lower in Group II: 152.4 cm/sec (IQR = 43.0) compared to 173.0 cm/sec (IQR = 32.0), p = 0.01. The E/A ratio and the incidence of E/A ≥2 showed a borderline significant difference (p = 0.04). Median E/e′ was higher in Group II - 9.2 (IQR = 5.4) compared to 6.4 (IQR = 4.2), p = 0.003. E/Vp was 1.2 (IQR = 0.4) versus 0.8 (IQR = 0.5), p less than 0.001. Diastolic dysfunction was more frequent in Group II, with significantly different echocardiographic parameters, including decreased E-wave velocity, increased E/e′ and E/Vp ratios, and a higher incidence of E/A ≥2. Conclusions. Patients undergoing both PCI and TAVI more frequently exhibited left ventricular diastolic dysfunction. The echocardiographic parameters E, E/e′, and E/Vp showed statistically significant differences, suggesting an additive impact of coronary artery disease on diastolic function impairment in the setting of severe aortic stenosis.