HWHaixia Wang

Haixia Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haixia Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • IPIDNN control system for aluminum-magnesium alloy thickness based on OSCDGM

    by Haixia Wang, Linsen Wang, Xiao Cheng, Kunjie Li, ZeDa Meng

    Purpose: This study tackles two challenges in aluminum-magnesium (Al-Mg) alloy rolling – control delay from measurement hysteresis and strong nonlinearity with limited passband precision – by proposing a predictive control scheme that couples an optimized starting-point combinatorial discrete grey model (OSCDGM), with an improved PID neural network (IPIDNN). Design/methodology/approach: An OSCDGM framework based on an Optimized Starting-Point Discrete Grey Model (OSDGM) uses change-point-driven updating with tail correction and Fourier-series residual compensation to achieve high-accuracy real-time prediction of inter-stand thickness. Predicted and measured values are fused to drive online learning of an IPIDNN controller, which augments a PID neural network through variable-speed integration, incomplete differentiation and tanh-based nonlinear mapping to enhance tracking, passband control and dynamic response. Findings: Field experiments show that OSCDGM reduces prediction errors by 36–42% relative to Even Grey Model (EGM), Discrete Grey Model (DGM) and Support Vector Machine (SVM). IPIDNN shortens settling time by 79–88% compared with Back Propagation-Proportional-Integral-Derivative (BP-PID), PID Neural Network (PIDNN) and model predictive control. Under disturbances and noise, the standard deviation of control deviation is reduced by 68% versus conventional PID, with fluctuations confined within ±3s and thickness accuracy improved by about 27% in production. Research limitations/implications: Application to full-pass rolling of AZ31B alloy verifies engineering applicability and demonstrates markedly improved thickness consistency and stability, while highlighting the need to assess generalization to alloys with different plastic properties. Originality/value: The study establishes an integrated architecture combining high-precision dynamic prediction with structurally enhanced neural-network-based control, providing a paradigm for intelligent control of high-precision metal rolling with significant time delays and nonlinearity.

  • Design and Experimental Evaluation of a Novel Robot-Assisted Surgical System for Pelvic Fracture Closed Reduction

    by Xiao Cheng, Wei Kou, Xinyu Chen, Dongya Li, Haixia Wang, Shaolong Kuang

    This paper designs a novel clinical-oriented robot-assisted surgical system (RASS) for pelvic fracture closed reduction, including three core parts: preoperative planning system, intraoperative navigation system and reduction robot. In preoperative planning system, a virtual reduction method based on the Statistical Shape Model (SSM) and pelvic partial surface data is adopted, providing personalized and detailed preoperative plans with high-efficiency and enhanced adaptability. Then, a serial-parallel hybrid reduction robot with robot autonomous and master-slave reduction mode switching control strategy is designed, combined with the intuitive and real-time guidance of the intraoperative navigation system, achieving flexible and precise reduction operations. Additionally, clinical solution research based on the designed RASS is developed and evaluated by ten pelvic models and five animal experiments. In the pelvic model experiments, the root mean square error (RMSE) of the distance between the reduced and intact pelvic point cloud is 1.0mm, and the three points error of 10 cases are all within 2.0mm, achieving an excellent reduction effect. In the animal experiments, the four point-pairs distance decreases from 26.7±1.04mm to 5.86±0.82mm, and the mean distance between the two point clouds of the "Pig-081" before modeling and after reduction is 2.81mm, which further confirmed the effectiveness of the system, as well as the feasibility and safety of the clinical solution. The designed novel RASS provides a promising solution in the treatment of pelvic fractures, and the experimental results lay the foundation for further clinical application.