Adriaan Mels
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Adriaan Mels has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Haifeng Jia
School of Environment, Tsinghua University, Beijing 100084, China
2 shared publications - Hao Zhang
Environmental Technology, Wageningen University & Research, P.O. Box 17, Wageningen 6700 AA, the Netherlands
2 shared publications - Huub H. M. Rijnaarts
Department of Environmental Technology, Wageningen University, Wageningen, The Netherlands
2 shared publications - Chuandong Jiang
Jilin University
1 shared publication - Hao Wu
College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130026, China
1 shared publication Wei-Shan Chen
1 shared publication
Latest Publications
- Open Access
- 28 May 2026
- Published by IWA Publishing in Water Science & Technology
- Vol. 93 (11) , 1674-1690
Proof-of-principle of Distributed Acoustic Sensing (DAS) for detection of sewer defects, extraneous water intrusion and sewage exfiltration
DAS framework for sewer defect detection, showing laboratory intrusion and exfiltration simulations, PSD-based localization, and field screening of CCTV-confirmed defects in an 800 m sewer. Extraneous water intrusion and sewage exfiltration due to sewer defects are difficult to detect. This study presents a potentially effective sewer defect diagnosis method, namely, the distributed acoustic sensing (DAS) framework. Firstly, a proof-of-principle study was performed using a 5-m sewer model for DAS signal analysis. Controlled intrusions were applied with defined flow rate and fall height, under defined static and dynamic background flows. Under laboratory conditions, pouring-induced intrusion events generated localized transient strain impacts with clear time- and frequency-domain fingerprints, enabling DAS to localize the impact region and distinguish between inflow-side and manhole-side responses. For exfiltration, time-domain responses of the DAS signals were too weak, but upon amplification of the power spectral density (PSD) between 20 and 30 Hz, leakages were detected by consistent and localized amplified signals under experimental scenarios. Secondly, a field test was conducted on an 800-m sanitary sewer in operation. Despite urban noise interference, statistical screening of amplified PSD signals between 20 and 30 Hz identified recurrent mid-level events to be associated with two candidate defective segments, which were later confirmed. These results provide an initial proof-of-principle field demonstration, but the field evidence remains limited and further validation is still required before broader engineering applicability.
- 28 May 2026
- Published by IWA Publishing in Water Science & Technology
- Vol. 93 (11) , 1674-1690
Open AccessProof-of-principle of Distributed Acoustic Sensing (DAS) for detection of sewer defects, extraneous water intrusion and sewage exfiltration
DAS framework for sewer defect detection, showing laboratory intrusion and exfiltration simulations, PSD-based localization, and field screening of CCTV-confirmed defects in an 800 m sewer. Extraneous water intrusion and sewage exfiltration due to sewer defects are difficult to detect. This study presents a potentially effective sewer defect diagnosis method, namely, the distributed acoustic sensing (DAS) framework. Firstly, a proof-of-principle study was performed using a 5-m sewer model for DAS signal analysis. Controlled intrusions were applied with defined flow rate and fall height, under defined static and dynamic background flows. Under laboratory conditions, pouring-induced intrusion events generated localized transient strain impacts with clear time- and frequency-domain fingerprints, enabling DAS to localize the impact region and distinguish between inflow-side and manhole-side responses. For exfiltration, time-domain responses of the DAS signals were too weak, but upon amplification of the power spectral density (PSD) between 20 and 30 Hz, leakages were detected by consistent and localized amplified signals under experimental scenarios. Secondly, a field test was conducted on an 800-m sanitary sewer in operation. Despite urban noise interference, statistical screening of amplified PSD signals between 20 and 30 Hz identified recurrent mid-level events to be associated with two candidate defective segments, which were later confirmed. These results provide an initial proof-of-principle field demonstration, but the field evidence remains limited and further validation is still required before broader engineering applicability.
- Open Access
- 9 October 2025
- Published by Elsevier in Water Research X
- Vol. 29
Extraneous water in sewer systems: A Comprehensive review on sewer infiltration and inflow quantification, localization and mitigation
- 9 October 2025
- Published by Elsevier in Water Research X
- Vol. 29
Open AccessExtraneous water in sewer systems: A Comprehensive review on sewer infiltration and inflow quantification, localization and mitigation