João Vitor Sciorilli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
João Vitor Sciorilli has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Maria Julia Lemos
Department of Medicine, Redentor University Center, Itaperuna, Rio de Janeiro, Brazil
3 shared publications - Bruna Benigna Sales Armstrong
Department of Obstetrics and Gynecology, Irmandade Santa Casa de Misericórdia
2 shared publications - Davi Barbosa Pereira da Silva
University Center of Maceió, Alagoas, Brazil
2 shared publications - Flávia Ribeiro de Oliveira
Department of Physiotherapy, School of Physical Education, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
2 shared publications - Isabella de Oliveira Ortiz
Department of Medicine, Santa Marcelina Hospital
2 shared publications - Juliana Almeida Oliveira
Federal University of Minas Gerais, Belo Horizonte, Brazil
2 shared publications
Latest Publications
- 23 September 2026
- Published by Federação das Associações de Ginecologia e Obstetrícia in Revista Brasileira de Ginecologia e Obstetrícia
- Vol. 48
Author´s reply to comment on: Prenatal exposure to paracetamol and risk of autism spectrum disorder: systematic review and meta-analysis of observational studies
- 23 September 2026
- Published by Federação das Associações de Ginecologia e Obstetrícia in Revista Brasileira de Ginecologia e Obstetrícia
- Vol. 48
Author´s reply to comment on: Prenatal exposure to paracetamol and risk of autism spectrum disorder: systematic review and meta-analysis of observational studies
- 9 March 2026
- Published by Springer Nature in Abdominal Radiology
Accuracy of magnetic resonance imaging for acute appendicitis in pregnant women: an updated diagnostic systematic review and meta-analysis
Diagnosing acute appendicitis during pregnancy is challenging due to physiological changes and concerns regarding fetal radiation exposure from Computed Tomography (CT). This systematic review and meta-analysis evaluates the diagnostic accuracy and safety of Magnetic Resonance Imaging (MRI) for suspected acute appendicitis, providing an updated synthesis based on a large dataset and modern MRI protocols. Following PRISMA guidelines and PROSPERO registration, we performed a systematic review and diagnostic meta-analysis. Studies involving pregnant women with suspected appendicitis, extractable diagnostic accuracy data (true positives, false positives, false negatives, true negatives), and surgical/histopathological confirmation were included. PubMed, EMBASE, and Cochrane Central were systematically searched until September 3, 2025. Risk of bias was assessed using QUADAS-2, and evidence certainty with GRADE. Statistical analysis used R, employing bivariate random-effects models for sensitivity/specificity, sROC curves, meta-regression, and Deeks' test for publication bias. Thirty-four studies were included. Pooled sensitivity was 0.95 (95% CI: 0.91-0.98; I² = 0%) and pooled specificity 0.97 (95% CI: 0.96-0.98; I² = 55.3%), demonstrating strong diagnostic performance (AUC = 0.961; Diagnostic Odds Ratio = 273.1). A positive MRI result increased post-test probability from 30% to 93%, while a negative result reduced it to 2.2%. QUADAS-2 revealed patient selection and index-test interpretation as common bias sources, particularly in older retrospective studies. Moderate heterogeneity in specificity (I² = 55.3%) was observed, but not explained by gestational age. Deeks' test indicated potential publication bias (p = 0.0024), though pooled estimates remained robust in sensitivity analyses. Non-contrast MRI is a highly accurate and safe diagnostic tool for suspected acute appendicitis in pregnancy, demonstrating performance comparable to CT in non-pregnant populations. We recommend MRI as the standard second-line imaging modality following inconclusive ultrasound findings to enhance diagnostic confidence, minimize fetal radiation exposure, and reduce unnecessary surgical interventions.
- 9 March 2026
- Published by Springer Nature in Abdominal Radiology
Accuracy of magnetic resonance imaging for acute appendicitis in pregnant women: an updated diagnostic systematic review and meta-analysis
Diagnosing acute appendicitis during pregnancy is challenging due to physiological changes and concerns regarding fetal radiation exposure from Computed Tomography (CT). This systematic review and meta-analysis evaluates the diagnostic accuracy and safety of Magnetic Resonance Imaging (MRI) for suspected acute appendicitis, providing an updated synthesis based on a large dataset and modern MRI protocols. Following PRISMA guidelines and PROSPERO registration, we performed a systematic review and diagnostic meta-analysis. Studies involving pregnant women with suspected appendicitis, extractable diagnostic accuracy data (true positives, false positives, false negatives, true negatives), and surgical/histopathological confirmation were included. PubMed, EMBASE, and Cochrane Central were systematically searched until September 3, 2025. Risk of bias was assessed using QUADAS-2, and evidence certainty with GRADE. Statistical analysis used R, employing bivariate random-effects models for sensitivity/specificity, sROC curves, meta-regression, and Deeks' test for publication bias. Thirty-four studies were included. Pooled sensitivity was 0.95 (95% CI: 0.91-0.98; I² = 0%) and pooled specificity 0.97 (95% CI: 0.96-0.98; I² = 55.3%), demonstrating strong diagnostic performance (AUC = 0.961; Diagnostic Odds Ratio = 273.1). A positive MRI result increased post-test probability from 30% to 93%, while a negative result reduced it to 2.2%. QUADAS-2 revealed patient selection and index-test interpretation as common bias sources, particularly in older retrospective studies. Moderate heterogeneity in specificity (I² = 55.3%) was observed, but not explained by gestational age. Deeks' test indicated potential publication bias (p = 0.0024), though pooled estimates remained robust in sensitivity analyses. Non-contrast MRI is a highly accurate and safe diagnostic tool for suspected acute appendicitis in pregnancy, demonstrating performance comparable to CT in non-pregnant populations. We recommend MRI as the standard second-line imaging modality following inconclusive ultrasound findings to enhance diagnostic confidence, minimize fetal radiation exposure, and reduce unnecessary surgical interventions.
- 7 October 2025
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (3) , 988-993
Cyanoacrylate glue for securing peripherally inserted intravenous catheters in the emergency department: A meta-analysis of randomized controlled trials
Background: Intravenous catheters (IVCs) are a common medical device, used in 70% of hospital patients. Due to their high failure ratio (35%–50%) and complications, we aimed to perform a systematic review and meta-analysis to assess the efficacy of Cyanoacrylate Glue (CG) use in preventing IV complications at the Emergency Department. Methods: This study was registered in PROSPERO on February 5, 2025, with registry number CRD42025642588 and received no financial support. A systematic search at PubMed, Embase, and Cochrane databases was performed and only Randomized Controlled Trials about CG use for securing IVCs were included. Results: Primary outcomes showed no statistical significance between the groups across all four outcomes at maximum follow-up. However, in a subgroup analysis including only adult patients, CG group presented lower IVCs dislodgement and failure events. Further studies in pediatric patients are needed.
- 7 October 2025
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (3) , 988-993
Cyanoacrylate glue for securing peripherally inserted intravenous catheters in the emergency department: A meta-analysis of randomized controlled trials
Background: Intravenous catheters (IVCs) are a common medical device, used in 70% of hospital patients. Due to their high failure ratio (35%–50%) and complications, we aimed to perform a systematic review and meta-analysis to assess the efficacy of Cyanoacrylate Glue (CG) use in preventing IV complications at the Emergency Department. Methods: This study was registered in PROSPERO on February 5, 2025, with registry number CRD42025642588 and received no financial support. A systematic search at PubMed, Embase, and Cochrane databases was performed and only Randomized Controlled Trials about CG use for securing IVCs were included. Results: Primary outcomes showed no statistical significance between the groups across all four outcomes at maximum follow-up. However, in a subgroup analysis including only adult patients, CG group presented lower IVCs dislodgement and failure events. Further studies in pediatric patients are needed.