Sophia E. Nigrovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sophia E. Nigrovic has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Adriana Payan-Medina
Center for Engineering in Medicine and Surgery, Department of Surgery, Massachusetts General Hospital, Charlestown, MA 02129, USA
1 shared publication Ankita Paul
Department of Chemistry
1 shared publicationAntara Ghosh
Department of Chemistry
1 shared publication- Avanish Mishra
Center for Engineering in Medicine and Surgery, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts 02129, USA
1 shared publication - Danielle H. Dube
Department of Chemistry & Biochemistry, Bowdoin College, 6600 College Station, Brunswick, Maine 04011, United States
1 shared publication Elizabeth A. Stemmler
Department of Chemistry & Biochemistry, Bowdoin College, 6600 College Station, Brunswick, Maine 04011, United States
1 shared publication
Latest Publications
- Open Access
Microfluidic T-Chip enables one-step clinical-scale T-cell purification from blood products for CAR T-cell manufacturing
Treatment with chimeric antigen receptor (CAR) T cells has emerged as a promising immune therapy for relapsed and refractory hematologic malignancies. The CAR T cells are manufactured in a series of steps that involve isolating T cells from the patient’s leukapheresis product, genetically modifying them to express the CAR against the target antigen, and reinfusing them into the patient. Efficient T-cell enrichment from leukapheresis products is critical to the success of these therapies. Current methods for T-cell sorting on a clinical scale involve several washing steps to remove red blood cells and platelets, followed by T-cell selection and activation. These multi-step processes result in cell loss during processing and involve several handling steps. Here, we utilize fluidically assembled micromagnetic lenses to develop a high-throughput, continuous-flow microfluidic T-cell sorter, designated as the T-Chip, for sorting magnetic bead-labeled CD3 + T cells in a single step. Our approach allows direct sorting of T cells in expansion media from leukopaks without any washing steps, effectively removing 99.999% of RBCs and platelets from the leukapheresis product. A single 1-inch x 3-inch T-Chip can process leukapheresis product at a throughput of 60 mL/hr and 2.56 ± 0.12 billion cells/hr. Using this optimized workflow, we demonstrate clinical-scale enrichment of highly pure CD3 + T cells (97.7 ± 1.3%) with high viability (97.0 ± 1.1%) and recovery (87.3 ± 14.8%) in a functionally closed manner. Downstream processing of T cells isolated using the T-Chip yielded potent anti-mesothelin CAR T cells with demonstrated anti-tumor efficacy. Overall, by exploiting precisely engineered magnetic forces and laminar flow, the microfluidic T-Chip overcomes bottlenecks caused by low throughput and enables single-step large-scale T-cell purification for the rapid development of CAR T cells.
Open AccessMicrofluidic T-Chip enables one-step clinical-scale T-cell purification from blood products for CAR T-cell manufacturing
Treatment with chimeric antigen receptor (CAR) T cells has emerged as a promising immune therapy for relapsed and refractory hematologic malignancies. The CAR T cells are manufactured in a series of steps that involve isolating T cells from the patient’s leukapheresis product, genetically modifying them to express the CAR against the target antigen, and reinfusing them into the patient. Efficient T-cell enrichment from leukapheresis products is critical to the success of these therapies. Current methods for T-cell sorting on a clinical scale involve several washing steps to remove red blood cells and platelets, followed by T-cell selection and activation. These multi-step processes result in cell loss during processing and involve several handling steps. Here, we utilize fluidically assembled micromagnetic lenses to develop a high-throughput, continuous-flow microfluidic T-cell sorter, designated as the T-Chip, for sorting magnetic bead-labeled CD3 + T cells in a single step. Our approach allows direct sorting of T cells in expansion media from leukopaks without any washing steps, effectively removing 99.999% of RBCs and platelets from the leukapheresis product. A single 1-inch x 3-inch T-Chip can process leukapheresis product at a throughput of 60 mL/hr and 2.56 ± 0.12 billion cells/hr. Using this optimized workflow, we demonstrate clinical-scale enrichment of highly pure CD3 + T cells (97.7 ± 1.3%) with high viability (97.0 ± 1.1%) and recovery (87.3 ± 14.8%) in a functionally closed manner. Downstream processing of T cells isolated using the T-Chip yielded potent anti-mesothelin CAR T cells with demonstrated anti-tumor efficacy. Overall, by exploiting precisely engineered magnetic forces and laminar flow, the microfluidic T-Chip overcomes bottlenecks caused by low throughput and enables single-step large-scale T-cell purification for the rapid development of CAR T cells.
- Open Access
- 13 October 2025
- Published by American Chemical Society (ACS) in ACS Infectious Diseases
- Vol. 11 (11) , 3355-3363
Examination of Acetylated Monosaccharides as Metabolic Probes in Bacteria
Bacterial glycans are validated antibiotic targets due to their crucial roles in supporting bacterial fitness and survival. The array of exclusively bacterial monosaccharides and their variable expression across bacterial species and serotypes present challenges in studying these structurally diverse molecules. Probes based on bacterial sugars have emerged as useful tools in metabolic labeling studies. Prior to the metabolic processing of probes by bacteria, most metabolic probes must be transported across the bacterial cell envelope. Probe acetylation has been used as one strategy to ease passive diffusion across the lipophilic cell membrane and relies on deacetylation by esterases within cells before subsequent metabolic processing into glycans is possible. However, inefficient probe deacetylation has the potential to yield artifactual labeling rather than physiological glycan labeling. Here, we systematically explored probe acetylation as a design criterion for metabolic labeling experiments in four bacterial species. Plesiomonas shigelloides, Vibrio vulnificus, and Helicobacter pylori exhibited a strong preference for metabolic incorporation of acetylated probes relative to unprotected probes, whereas Bacteroides fragilis incorporated both unprotected and acetylated probes at comparable levels. Curiously, only B. fragilis had sufficient esterase activity to quantitatively deacetylate a peracetylated monosaccharide probe in situ. These findings suggest the importance of validating acetylated probes on a case-by-case basis to ensure physiologically relevant bacterial glycan labeling.
- 13 October 2025
- Published by American Chemical Society (ACS) in ACS Infectious Diseases
- Vol. 11 (11) , 3355-3363
Open AccessExamination of Acetylated Monosaccharides as Metabolic Probes in Bacteria
Bacterial glycans are validated antibiotic targets due to their crucial roles in supporting bacterial fitness and survival. The array of exclusively bacterial monosaccharides and their variable expression across bacterial species and serotypes present challenges in studying these structurally diverse molecules. Probes based on bacterial sugars have emerged as useful tools in metabolic labeling studies. Prior to the metabolic processing of probes by bacteria, most metabolic probes must be transported across the bacterial cell envelope. Probe acetylation has been used as one strategy to ease passive diffusion across the lipophilic cell membrane and relies on deacetylation by esterases within cells before subsequent metabolic processing into glycans is possible. However, inefficient probe deacetylation has the potential to yield artifactual labeling rather than physiological glycan labeling. Here, we systematically explored probe acetylation as a design criterion for metabolic labeling experiments in four bacterial species. Plesiomonas shigelloides, Vibrio vulnificus, and Helicobacter pylori exhibited a strong preference for metabolic incorporation of acetylated probes relative to unprotected probes, whereas Bacteroides fragilis incorporated both unprotected and acetylated probes at comparable levels. Curiously, only B. fragilis had sufficient esterase activity to quantitatively deacetylate a peracetylated monosaccharide probe in situ. These findings suggest the importance of validating acetylated probes on a case-by-case basis to ensure physiologically relevant bacterial glycan labeling.