Sara Fedele
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sara Fedele has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Anna Fornaciari
Anesthesiology, Critical Care and Pain Medicine Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126 Parma, Italy
1 shared publication - Elena Bignami
Anesthesiology, Critical Care and Pain Medicine Division, Department of Medicine and Surgery, University of Parma, Parma, Italy
1 shared publication - Erika Cerdelli
Anesthesiology, Critical Care and Pain Medicine Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126 Parma, Italy
1 shared publication - Francesco Marconi
Anesthesiology, Critical Care and Pain Medicine Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126 Parma, Italy
1 shared publication - Matteo Panizzi
Anesthesiology, Critical Care and Pain Medicine Division, Department of Medicine and Surgery, University of Parma, Viale Gramsci 14, 43126 Parma, Italy
1 shared publication - Mattia Madeo
Anesthesiology, Critical Care and Pain Medicine Division, Department of Medicine and Surgery, University of Parma, Parma, Italy
1 shared publication
Latest Publications
- Open Access
Wearable Devices in Healthcare Beyond the One-Size-Fits All Paradigm
Wearable devices (WDs) are increasingly integrated into clinical workflows to enable continuous, non-invasive vital signs monitoring. Combined with Artificial Intelligence (AI), these systems can shift clinical monitoring from being reactive to predictive, allowing for earlier detection of deterioration and more personalized interventions. The value of these technologies lies not in absolute measurements, but in detecting physiological parameters trends relative to each patient’s baseline. Such a trend-based approach enables real-time prediction of deterioration, enhancing patient safety and continuity of care. However, despite their shared multiparametric capabilities, WDs are not interchangeable. This narrative review analyzes nine clinically validated devices, Radius VSM® (Masimo Corporation, Irvine, CA, USA), BioButton® (BioIntelliSense Inc., Redwood City, CA, USA. Distributed by Medtronic), Portrait Mobile® (GE HealthCare, Chicago, IL, USA), VitalPatch® (VitalConnect Inc., San Jose, CA, USA), CardioWatch 287-2® (Corsano Health B.V., The Hague, The Netherlands. Distributed by Medtronic), Cosinuss C-Med Alpha® (Cosinuss Gmb, Munich, Germany), SensiumVitals® (Sensium Healthcare Limited, Abingdon, Oxfordshire, UK), Isansys Lifetouch® (Isansys Lifecare Ltd., Abingdon, Oxfordshire, UK), and CheckPoint Cardio® (CheckPoint R&D LTD., Kazanlak, Bulgaria), highlighting how differences in sensor configurations, battery life, connectivity, and validation contexts influence their suitability across various clinical environments. Rather than establishing a hierarchy of technical superiority, this review emphasizes the importance of context-driven selection, considering care setting, patient profile, infrastructure requirements, and interoperability. Each device demonstrates strengths and limitations depending on patient population and operational demands, ranging from perioperative, post-operative, emergency, or post-Intensive Care Unit (ICU) settings. The findings support a tailored approach to WD implementation, where matching device capabilities to clinical needs is key to maximizing utility, safety, and efficiency.
Open AccessWearable Devices in Healthcare Beyond the One-Size-Fits All Paradigm
Wearable devices (WDs) are increasingly integrated into clinical workflows to enable continuous, non-invasive vital signs monitoring. Combined with Artificial Intelligence (AI), these systems can shift clinical monitoring from being reactive to predictive, allowing for earlier detection of deterioration and more personalized interventions. The value of these technologies lies not in absolute measurements, but in detecting physiological parameters trends relative to each patient’s baseline. Such a trend-based approach enables real-time prediction of deterioration, enhancing patient safety and continuity of care. However, despite their shared multiparametric capabilities, WDs are not interchangeable. This narrative review analyzes nine clinically validated devices, Radius VSM® (Masimo Corporation, Irvine, CA, USA), BioButton® (BioIntelliSense Inc., Redwood City, CA, USA. Distributed by Medtronic), Portrait Mobile® (GE HealthCare, Chicago, IL, USA), VitalPatch® (VitalConnect Inc., San Jose, CA, USA), CardioWatch 287-2® (Corsano Health B.V., The Hague, The Netherlands. Distributed by Medtronic), Cosinuss C-Med Alpha® (Cosinuss Gmb, Munich, Germany), SensiumVitals® (Sensium Healthcare Limited, Abingdon, Oxfordshire, UK), Isansys Lifetouch® (Isansys Lifecare Ltd., Abingdon, Oxfordshire, UK), and CheckPoint Cardio® (CheckPoint R&D LTD., Kazanlak, Bulgaria), highlighting how differences in sensor configurations, battery life, connectivity, and validation contexts influence their suitability across various clinical environments. Rather than establishing a hierarchy of technical superiority, this review emphasizes the importance of context-driven selection, considering care setting, patient profile, infrastructure requirements, and interoperability. Each device demonstrates strengths and limitations depending on patient population and operational demands, ranging from perioperative, post-operative, emergency, or post-Intensive Care Unit (ICU) settings. The findings support a tailored approach to WD implementation, where matching device capabilities to clinical needs is key to maximizing utility, safety, and efficiency.