Cristina Viscido
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cristina Viscido has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Edoardo Zingarelli
Department of Cardiac Surgery, Mauriziano Hospital, 10128 Turin, Italy
2 shared publications - Enrico Giuseppe Italiano
Division of Cardiac Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, 35122 Padua, Italy
2 shared publications - Gabriella Buono
Department of Cardiovascular Anesthesia and Intensive Care, Mauriziano Hospital, 10128 Turin, Italy
2 shared publications - Luca Weltert
Department of Cardiac Surgery, European Hospital, Rome, Italy
2 shared publications - Paolo Centofanti
Department of Cardiac Surgery, Mauriziano Hospital, 10128 Turin, Italy
2 shared publications - Vittoria Lodo
Cardiac Surgery Department, Mauriziano Hospital , Turin
2 shared publications
Latest Publications
- Top Cited Papers
- 24 February 2026
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 137 (1) , 110-117
Association of duration of amino acids infusion and renal protection: a secondary analysis of the PROTECTION trial
- 24 February 2026
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 137 (1) , 110-117
Top Cited PapersAssociation of duration of amino acids infusion and renal protection: a secondary analysis of the PROTECTION trial
- Open Access
- 21 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8278
Aortic Valve Replacement vs. Balloon-Expandable and Self-Expandable Transcatheter Implantation in Low-Risk Patients
Objectives: This study sought to compare midterm outcomes of low-risk patients who underwent a surgical aortic valve replacement (SAVR) vs. balloon-expandable (BE) or self-expandable (SE) transcatheter aortic valve implantation (TAVI). Methods: Data on consecutive patients undergoing SAVR or transfemoral TAVI between 2017 and 2022 were collected. Patients were separated into three groups according to the type of prosthesis: a biological surgical prosthesis, BE prosthesis and SE prosthesis. The three groups were compared in terms of baseline characteristics, post-procedural outcomes and long-term survival. Results: A total of 542 patients were enrolled, and 221 received a surgical prothesis, 150 received a BE prosthesis and 171 received an SE prosthesis. TAVI patients were older and had a higher risk profile compared to surgical patients. Propensity score matching resulted in an excellent matching of nearly 80 patients in each group. In the matched cohort, SE prostheses were associated with a significantly higher incidence of stroke (SE group 6.3%, BE group 0, SAVR group 2.3%, p = 0.045), para-valvular leak (SE group 8.1%, BE group 2.4%, SAVR group 0, p = 0.017) and left bundle branch block (SE group 23.8%, BE group 18.2%, SAVR group 0%, p < 0.001). Regarding 5-year mortality, no significant differences were reported between the BE and SE TAVI (13.6% vs. 22.5%, p = 0.066). However, when comparing surgery versus TAVI, the SE prosthesis showed a significantly higher 5-year mortality (22.5% vs. 11.6%, p = 0.042). Instead, the BE prosthesis demonstrated its non-inferiority compared to the surgical prosthesis (13.6% vs. 11.6%, p = 0.249). Conclusions: The BE prosthesis should be considered the prosthesis of choice for patients with a long life expectancy requiring a transcatheter procedure.
- 21 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8278
Open AccessAortic Valve Replacement vs. Balloon-Expandable and Self-Expandable Transcatheter Implantation in Low-Risk Patients
Objectives: This study sought to compare midterm outcomes of low-risk patients who underwent a surgical aortic valve replacement (SAVR) vs. balloon-expandable (BE) or self-expandable (SE) transcatheter aortic valve implantation (TAVI). Methods: Data on consecutive patients undergoing SAVR or transfemoral TAVI between 2017 and 2022 were collected. Patients were separated into three groups according to the type of prosthesis: a biological surgical prosthesis, BE prosthesis and SE prosthesis. The three groups were compared in terms of baseline characteristics, post-procedural outcomes and long-term survival. Results: A total of 542 patients were enrolled, and 221 received a surgical prothesis, 150 received a BE prosthesis and 171 received an SE prosthesis. TAVI patients were older and had a higher risk profile compared to surgical patients. Propensity score matching resulted in an excellent matching of nearly 80 patients in each group. In the matched cohort, SE prostheses were associated with a significantly higher incidence of stroke (SE group 6.3%, BE group 0, SAVR group 2.3%, p = 0.045), para-valvular leak (SE group 8.1%, BE group 2.4%, SAVR group 0, p = 0.017) and left bundle branch block (SE group 23.8%, BE group 18.2%, SAVR group 0%, p < 0.001). Regarding 5-year mortality, no significant differences were reported between the BE and SE TAVI (13.6% vs. 22.5%, p = 0.066). However, when comparing surgery versus TAVI, the SE prosthesis showed a significantly higher 5-year mortality (22.5% vs. 11.6%, p = 0.042). Instead, the BE prosthesis demonstrated its non-inferiority compared to the surgical prosthesis (13.6% vs. 11.6%, p = 0.249). Conclusions: The BE prosthesis should be considered the prosthesis of choice for patients with a long life expectancy requiring a transcatheter procedure.
- Open Access
- 21 October 2025
- Published by MDPI AG in Preprints.org
Aortic Valve Replacement vs Balloon-Expandable and Self-Expandable Transcatheter Implantation in Low-Risk Patients
Aims: this study sought to compare midterm outcomes of low-risk patients who underwent surgical aortic valve replacement (SAVR) vs balloon expandable (BE) or self-expandable (SE) TAVI. Methods: data of consecutive patients undergoing SAVR or transfemoral TAVI between 2017 and 2022 were collected. Patients were separated in 3 groups according to the type of prosthesis: biological surgical prosthesis, BE prosthesis and SE prosthesis. The 3 groups were compared in terms of baseline characteristics, post-procedural outcomes and long-term survival. Results: 542 patients were enrolled. 221 received a surgical prothesis, 150 received a BE prosthesis and 171 a SE prosthesis. TAVI patients were older and with a higher risk profile compared to surgical patients. Propensity score matching resulted in an excellent matching of nearly 80 patients in each group. In the matched cohort, SE prostheses were associated with a significantly higher incidence of stroke (SE group 6.3%, BE group 0, SAVR group 2.3%, p=0.045), para-valvular leak (SE group 8.1%, BE group 2.4%, SAVR group 0, p=0.017) and left bundle branch block (SE group 23.8%, BE group 18.2%, SAVR group 0 %, p< 0.001). Regarding 5-year mortality no significant differences were reported between BE and SE TAVI (13.6% vs22.5%, p=0.066). However, when comparing surgery versus TAVI, SE prosthesis showed a significantly higher 5-year mortality (22.5% vs 11.6%, p=0.042). Instead, BE prosthesis demonstrated their non inferiority compared to surgical prosthesis (13.6% vs 11.6%, p=0.249). Conclusion: BE prosthesis should be considered the prosthesis of choice for patients with long life-expectancy requiring a transcatheter procedure.
- 21 October 2025
- Published by MDPI AG in Preprints.org
Open AccessAortic Valve Replacement vs Balloon-Expandable and Self-Expandable Transcatheter Implantation in Low-Risk Patients
Aims: this study sought to compare midterm outcomes of low-risk patients who underwent surgical aortic valve replacement (SAVR) vs balloon expandable (BE) or self-expandable (SE) TAVI. Methods: data of consecutive patients undergoing SAVR or transfemoral TAVI between 2017 and 2022 were collected. Patients were separated in 3 groups according to the type of prosthesis: biological surgical prosthesis, BE prosthesis and SE prosthesis. The 3 groups were compared in terms of baseline characteristics, post-procedural outcomes and long-term survival. Results: 542 patients were enrolled. 221 received a surgical prothesis, 150 received a BE prosthesis and 171 a SE prosthesis. TAVI patients were older and with a higher risk profile compared to surgical patients. Propensity score matching resulted in an excellent matching of nearly 80 patients in each group. In the matched cohort, SE prostheses were associated with a significantly higher incidence of stroke (SE group 6.3%, BE group 0, SAVR group 2.3%, p=0.045), para-valvular leak (SE group 8.1%, BE group 2.4%, SAVR group 0, p=0.017) and left bundle branch block (SE group 23.8%, BE group 18.2%, SAVR group 0 %, p< 0.001). Regarding 5-year mortality no significant differences were reported between BE and SE TAVI (13.6% vs22.5%, p=0.066). However, when comparing surgery versus TAVI, SE prosthesis showed a significantly higher 5-year mortality (22.5% vs 11.6%, p=0.042). Instead, BE prosthesis demonstrated their non inferiority compared to surgical prosthesis (13.6% vs 11.6%, p=0.249). Conclusion: BE prosthesis should be considered the prosthesis of choice for patients with long life-expectancy requiring a transcatheter procedure.