Ahmet Tohumcu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmet Tohumcu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Serhat Efeoglu
Ankara University Faculty of Dentistry and Oral Maxillofacial Radiology, Yenimahalle, Türkiye
3 shared publications - Aysenur Oncu
Department of Endodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
1 shared publication - Berkan Celikten
Department of Endodontics, Faculty of Dentistry, Ankara University, Ankara 06560, Turkey
1 shared publication - Ecem Ozgur
Faculty of Dentistry Department of Endodontics Ankara University Ankara Turkey
1 shared publication Ercan Ucar
Faculty of Dentistry / Oral Maxillofacial Surgery, Adıyaman University, Adıyaman, Türkiye
1 shared publication- Esin Akol Görgün
Adiyaman Universitesi
1 shared publication
Latest Publications
- Open Access
- 21 July 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Impact of the 2023 Kahramanmaraş earthquakes on oral health-related quality of life: roles of disaster exposure, anxiety, and clinical safety concerns
- 21 July 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open AccessImpact of the 2023 Kahramanmaraş earthquakes on oral health-related quality of life: roles of disaster exposure, anxiety, and clinical safety concerns
- Open Access
- 24 October 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-10
Localization of the mental foramen in relation to the mandibular bone using ultrasonography and orthopantomography: a comparative study in the Turkish population
The mental foramen (MF) is a critical anatomical landmark in dental and maxillofacial procedures. Accurate localization is essential to avoid nerve injury. While orthopantomography (OPG) is commonly used, it has limitations due to its two-dimensional nature and susceptibility to artifacts. Ultrasonography (USG), which offers real-time imaging without ionizing radiation, has emerged as a promising alternative. This study aimed to compare the effectiveness of OPG and USG in identifying the MF and measuring its distance to the mandibular bone. A total of 120 patients (60 males, 60 females), aged 18 and older, were included in the study. A total of 240 mental foramina were evaluated. Vertical measurements were taken from the superior border of the MF to the alveolar crest and from the inferior border to the inferior cortical border of the mandible. Ultrasonographic imaging was performed using an extraoral probe in a longitudinal position. OPGs were acquired using standard protocols, and calibration was achieved by attaching orthodontic wires to the second premolars. All measurements were taken on calibrated digital images using dedicated measurement software. Statistical analysis included paired samples t-test, one-way ANOVA, independent samples t-test, and Pearson correlation. Significant differences were found between the two methods in all regions (p < 0.05), with OPG yielding higher distance values than USG. MF–mandibular bone distances were significantly greater in males than in females (p < 0.01). OPG showed significantly greater inferior distances in participants aged 40 years and older, while USG revealed no significant age-related differences. A strong positive correlation (r = 0.801–0.911) and high intra-observer reliability (r = 0.982–0.996) were observed between the methods. This study demonstrates that USG is a reliable, non-invasive alternative to OPG for locating the mental foramen. Both methods showed a strong correlation (r = 0.801–0.911), with USG minimizing radiation exposure. OPG yielded higher distance values (14.42 mm right, 14.27 mm left) compared to USG (14.12 mm right, 14.03 mm left) (p < 0.05). MF–mandibular bone distances were significantly greater in males than females (p < 0.01). USG is a valuable complementary tool in clinical practice. Not applicable. This study did not involve a health care intervention and was not a clinical trial.
- 24 October 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-10
Open AccessLocalization of the mental foramen in relation to the mandibular bone using ultrasonography and orthopantomography: a comparative study in the Turkish population
The mental foramen (MF) is a critical anatomical landmark in dental and maxillofacial procedures. Accurate localization is essential to avoid nerve injury. While orthopantomography (OPG) is commonly used, it has limitations due to its two-dimensional nature and susceptibility to artifacts. Ultrasonography (USG), which offers real-time imaging without ionizing radiation, has emerged as a promising alternative. This study aimed to compare the effectiveness of OPG and USG in identifying the MF and measuring its distance to the mandibular bone. A total of 120 patients (60 males, 60 females), aged 18 and older, were included in the study. A total of 240 mental foramina were evaluated. Vertical measurements were taken from the superior border of the MF to the alveolar crest and from the inferior border to the inferior cortical border of the mandible. Ultrasonographic imaging was performed using an extraoral probe in a longitudinal position. OPGs were acquired using standard protocols, and calibration was achieved by attaching orthodontic wires to the second premolars. All measurements were taken on calibrated digital images using dedicated measurement software. Statistical analysis included paired samples t-test, one-way ANOVA, independent samples t-test, and Pearson correlation. Significant differences were found between the two methods in all regions (p < 0.05), with OPG yielding higher distance values than USG. MF–mandibular bone distances were significantly greater in males than in females (p < 0.01). OPG showed significantly greater inferior distances in participants aged 40 years and older, while USG revealed no significant age-related differences. A strong positive correlation (r = 0.801–0.911) and high intra-observer reliability (r = 0.982–0.996) were observed between the methods. This study demonstrates that USG is a reliable, non-invasive alternative to OPG for locating the mental foramen. Both methods showed a strong correlation (r = 0.801–0.911), with USG minimizing radiation exposure. OPG yielded higher distance values (14.42 mm right, 14.27 mm left) compared to USG (14.12 mm right, 14.03 mm left) (p < 0.05). MF–mandibular bone distances were significantly greater in males than females (p < 0.01). USG is a valuable complementary tool in clinical practice. Not applicable. This study did not involve a health care intervention and was not a clinical trial.
- Open Access
- 21 October 2025
- Published by MDPI AG in Tomography
- Vol. 11 (10) , 116
Diagnostic Performance of CBCT in Detecting Different Types of Root Fractures with Various Intracanal Post Systems
Objective: This study aimed to evaluate the diagnostic accuracy of two cone beam computed tomography (CBCT) devices using 18 imaging modalities in detecting root fractures—vertical, horizontal, and oblique—in teeth with intracanal post systems. Materials and methods: Ninety-six were extracted; single-rooted mandibular premolars were endodontically treated and restored with Bundle, Reforpost, or Splendor Single Adjustable posts. Controlled fractures of different types were induced using a universal testing machine. Each tooth was scanned with NewTom 7G and NewTom Go (Quantitative Radiology, Verona, Italy) under nine imaging protocols per device; varying in dose and voxel size, yielding 1728 CBCT images. Three observers (a professor of endodontics; a specialist; and a postgraduate student in endodontics) independently evaluated the images. Results: Observers demonstrated almost perfect agreement (κ ≥ 0.81) with the gold standard in fracture detection using NewTom 7G. No significant differences were found in sensitivity, specificity, or accuracy across voxel size and dose parameters for both devices in detecting fracture presence (p > 0.05). Similarly, both devices displayed comparable performance in identifying horizontal and oblique fractures (p > 0.05). However, in NewTom Go, regular and low doses with different voxel sizes showed reduced sensitivity and accuracy in detecting vertical fractures across all post systems (p ≤ 0.05). Conclusions: NewTom 7G, with its advanced detector system and smaller voxel sizes, provides superior diagnostic accuracy for root fractures. In contrast, NewTom Go displays reduced sensitivity for vertical fractures at lower settings. Clinical relevance: CBCT device selection and imaging protocols significantly affect the diagnosis of vertical root fractures.
- 21 October 2025
- Published by MDPI AG in Tomography
- Vol. 11 (10) , 116
Open AccessDiagnostic Performance of CBCT in Detecting Different Types of Root Fractures with Various Intracanal Post Systems
Objective: This study aimed to evaluate the diagnostic accuracy of two cone beam computed tomography (CBCT) devices using 18 imaging modalities in detecting root fractures—vertical, horizontal, and oblique—in teeth with intracanal post systems. Materials and methods: Ninety-six were extracted; single-rooted mandibular premolars were endodontically treated and restored with Bundle, Reforpost, or Splendor Single Adjustable posts. Controlled fractures of different types were induced using a universal testing machine. Each tooth was scanned with NewTom 7G and NewTom Go (Quantitative Radiology, Verona, Italy) under nine imaging protocols per device; varying in dose and voxel size, yielding 1728 CBCT images. Three observers (a professor of endodontics; a specialist; and a postgraduate student in endodontics) independently evaluated the images. Results: Observers demonstrated almost perfect agreement (κ ≥ 0.81) with the gold standard in fracture detection using NewTom 7G. No significant differences were found in sensitivity, specificity, or accuracy across voxel size and dose parameters for both devices in detecting fracture presence (p > 0.05). Similarly, both devices displayed comparable performance in identifying horizontal and oblique fractures (p > 0.05). However, in NewTom Go, regular and low doses with different voxel sizes showed reduced sensitivity and accuracy in detecting vertical fractures across all post systems (p ≤ 0.05). Conclusions: NewTom 7G, with its advanced detector system and smaller voxel sizes, provides superior diagnostic accuracy for root fractures. In contrast, NewTom Go displays reduced sensitivity for vertical fractures at lower settings. Clinical relevance: CBCT device selection and imaging protocols significantly affect the diagnosis of vertical root fractures.