Astrid Bergmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Astrid Bergmann has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Vera von Dossow
Ruhr Universität Bochum, Universität Bielefeld, Campus OWL
5 shared publications - Nikolai Hulde
Heart- and Diabetes-Center Bad Oeynhausen, Ruhr-University Bochum, 32545 Bad Oeynhausen, Germany
4 shared publications Tanja Rudolph
Ruhr-University Bochum, Heart- and Diabetes-Center, 32545 Bad Oeynhausen, Germany
3 shared publicationsCornelia Piper
Ruhr-University Bochum, Heart- and Diabetes-Center, 32545 Bad Oeynhausen, Germany
2 shared publicationsFlorian Hildebrandt
Telehealth Competence Center (TCC), 22083 Hamburg, Germany
2 shared publicationsHelmut Warkentin
Ruhr-University Bochum, Heart- and Diabetes-Center, 32545 Bad Oeynhausen, Germany
2 shared publications
Latest Publications
- Open Access
Physiological Responses to a Sequential Higher-Frequency Low Tidal Volume Ventilation Protocol During Radiofrequency Atrial Fibrillation Ablation: A Single-Center Subgroup Proof-of-Concept Study
The physiological effects of mechanical ventilation are subject to ongoing research. Conventional ventilation may contribute to pulmonary volutrauma or barotrauma and influence cardiovascular physiology through changes in intrathoracic pressure. In the multicenter Ablate-by-LAWT study, patients undergoing atrial fibrillation ablation were ventilated using a higher-frequency, low tidal ventilation (HFLTV) protocol. This post hoc single-center subgroup proof-of-concept study aimed to characterize physiological responses to HFLTV using left atrial pressure (LAP), gas exchange, and hemodynamic parameters during sequential, nonrandomized volume-controlled ventilation (VCV) and HFLTV. The ventilation protocols differed in respiratory rate, tidal volume, PEEP, FiO2, and I:E ratio. Twelve patients were included, and differences between ventilation strategies were assessed using two-sided paired t-tests. Compared with VCV, HFLTV was associated with lower systolic LAP (Mean Difference (MD) −3.33 mmHg, 95% confidence interval (CI) [−5.61; −1.06], p = 0.008), whereas post hoc estimated mean LAP was similar between ventilation periods (MD −0.06 mmHg, 95% CI [−2.19; 2.08], p = 0.955). Heart rate (MD 8.1 bpm, 95% CI [3.8; 12.4], p = 0.002), mean arterial pressure (MD 11.5 mmHg, 95% CI [7.1; 15.9], p < 0.001), and cardiac index (MD 0.64 L/min/m2, 95% CI [0.29; 0.99], p = 0.002) were higher during HFLTV. The partial arterial pressure of oxygen (PaO2) was lower during HFLTV (MD −42.3 mmHg, 95% CI [−83.5; −1.1], p = 0.045, FDR-adjusted p = 0.072), and the partial arterial pressure of carbon dioxide (PaCO2) (MD −1.1 mmHg, 95% CI [−6.0; 3.7], p = 0.623) and the PaO2/FiO2 ratio (MD −49.3 mmHg, 95% CI [−105.2; 6.7], p = 0.079) did not differ significantly. Given the fixed-order design and simultaneous modification of multiple ventilatory parameters, these exploratory findings should be considered hypothesis-generating and cannot be attributed to individual components of the HFLTV protocol.
Open AccessPhysiological Responses to a Sequential Higher-Frequency Low Tidal Volume Ventilation Protocol During Radiofrequency Atrial Fibrillation Ablation: A Single-Center Subgroup Proof-of-Concept Study
The physiological effects of mechanical ventilation are subject to ongoing research. Conventional ventilation may contribute to pulmonary volutrauma or barotrauma and influence cardiovascular physiology through changes in intrathoracic pressure. In the multicenter Ablate-by-LAWT study, patients undergoing atrial fibrillation ablation were ventilated using a higher-frequency, low tidal ventilation (HFLTV) protocol. This post hoc single-center subgroup proof-of-concept study aimed to characterize physiological responses to HFLTV using left atrial pressure (LAP), gas exchange, and hemodynamic parameters during sequential, nonrandomized volume-controlled ventilation (VCV) and HFLTV. The ventilation protocols differed in respiratory rate, tidal volume, PEEP, FiO2, and I:E ratio. Twelve patients were included, and differences between ventilation strategies were assessed using two-sided paired t-tests. Compared with VCV, HFLTV was associated with lower systolic LAP (Mean Difference (MD) −3.33 mmHg, 95% confidence interval (CI) [−5.61; −1.06], p = 0.008), whereas post hoc estimated mean LAP was similar between ventilation periods (MD −0.06 mmHg, 95% CI [−2.19; 2.08], p = 0.955). Heart rate (MD 8.1 bpm, 95% CI [3.8; 12.4], p = 0.002), mean arterial pressure (MD 11.5 mmHg, 95% CI [7.1; 15.9], p < 0.001), and cardiac index (MD 0.64 L/min/m2, 95% CI [0.29; 0.99], p = 0.002) were higher during HFLTV. The partial arterial pressure of oxygen (PaO2) was lower during HFLTV (MD −42.3 mmHg, 95% CI [−83.5; −1.1], p = 0.045, FDR-adjusted p = 0.072), and the partial arterial pressure of carbon dioxide (PaCO2) (MD −1.1 mmHg, 95% CI [−6.0; 3.7], p = 0.623) and the PaO2/FiO2 ratio (MD −49.3 mmHg, 95% CI [−105.2; 6.7], p = 0.079) did not differ significantly. Given the fixed-order design and simultaneous modification of multiple ventilatory parameters, these exploratory findings should be considered hypothesis-generating and cannot be attributed to individual components of the HFLTV protocol.
- Open Access
Preoperative Transcranial Doppler Findings and Postoperative Delirium After Cardiac Surgery in Elderly Patients: A Prospective Observational Study
Postoperative delirium (POD) is a common neurocognitive complication after cardiac surgery in elderly patients and is associated with adverse clinical outcomes. Impaired cerebral autoregulation and reduced cerebrovascular reserve may contribute to POD development. Automated transcranial Doppler sonography (TCD) enables non-invasive assessment of intracranial hemodynamics and may provide additional information for perioperative risk assessment. In this prospective single-center observational study, 108 patients aged >70 years scheduled for elective cardiac surgery with cardiopulmonary bypass were enrolled. Patients who had pre-existing neurological disease, had a pathological carotid Doppler ultrasound, underwent emergency surgery, or were unable to undergo delirium screening were excluded. Preoperative bilateral TCD of the middle cerebral arteries was performed using an automated WAKIe R3 system. POD was assessed on postoperative days 1–3 using the CAM-ICU. The primary endpoint was the occurrence of POD. Twenty-one patients were excluded, leaving 87 patients for analysis. POD occurred in 14 patients (16%). All patients who developed POD had pathological preoperative TCD findings, whereas no POD occurred among patients with normal TCD examinations. Overall, 82 patients (94%) demonstrated pathological intracranial hemodynamic findings despite normal carotid Doppler ultrasound. In multivariable Firth logistic regression adjusted for age and sex, pathological TCD findings remained associated with POD; however, interpretation was limited by the small number of outcome events and quasi-complete separation. In elderly patients undergoing cardiac surgery with cardiopulmonary bypass, pathological preoperative TCD findings were frequently observed and may be associated with an increased risk of postoperative delirium. The marked discrepancy between normal carotid ultrasound and abnormal intracranial hemodynamics suggests that TCD may provide complementary information regarding cerebrovascular function. Given the limited sample size and event rate, these findings should be considered exploratory and require confirmation in larger multicenter studies.
Open AccessPreoperative Transcranial Doppler Findings and Postoperative Delirium After Cardiac Surgery in Elderly Patients: A Prospective Observational Study
Postoperative delirium (POD) is a common neurocognitive complication after cardiac surgery in elderly patients and is associated with adverse clinical outcomes. Impaired cerebral autoregulation and reduced cerebrovascular reserve may contribute to POD development. Automated transcranial Doppler sonography (TCD) enables non-invasive assessment of intracranial hemodynamics and may provide additional information for perioperative risk assessment. In this prospective single-center observational study, 108 patients aged >70 years scheduled for elective cardiac surgery with cardiopulmonary bypass were enrolled. Patients who had pre-existing neurological disease, had a pathological carotid Doppler ultrasound, underwent emergency surgery, or were unable to undergo delirium screening were excluded. Preoperative bilateral TCD of the middle cerebral arteries was performed using an automated WAKIe R3 system. POD was assessed on postoperative days 1–3 using the CAM-ICU. The primary endpoint was the occurrence of POD. Twenty-one patients were excluded, leaving 87 patients for analysis. POD occurred in 14 patients (16%). All patients who developed POD had pathological preoperative TCD findings, whereas no POD occurred among patients with normal TCD examinations. Overall, 82 patients (94%) demonstrated pathological intracranial hemodynamic findings despite normal carotid Doppler ultrasound. In multivariable Firth logistic regression adjusted for age and sex, pathological TCD findings remained associated with POD; however, interpretation was limited by the small number of outcome events and quasi-complete separation. In elderly patients undergoing cardiac surgery with cardiopulmonary bypass, pathological preoperative TCD findings were frequently observed and may be associated with an increased risk of postoperative delirium. The marked discrepancy between normal carotid ultrasound and abnormal intracranial hemodynamics suggests that TCD may provide complementary information regarding cerebrovascular function. Given the limited sample size and event rate, these findings should be considered exploratory and require confirmation in larger multicenter studies.
- Open Access
- 26 May 2026
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 27 (5)
General Anaesthesia Versus Conscious Sedation in Transcatheter Aortic Valve Implantation: Differences in Pulmonary Infections
Background: Patients undergoing transfemoral aortic valve replacement are particularly vulnerable and require a more sophisticated anesthetic therapeutic approach. According to the literature, no study has directly compared general anaesthesia with conscious analgosedation using postoperative infections as the primary endpoint. Methods: Patients undergoing transcatheter aortic valve implantation (TAVI) were analyzed retrospectively. A total of 3313 patients from a large heart center in Western Europe were included in this study. One group received general anaesthesia, and the other group received analgosedation for TAVI. The primary outcome was postinterventional pneumonia; secondary outcomes included myocardial infarction, renal failure, stroke, and 30-day mortality. Propensity score matching using 16 matching criteria yielded over 1000 pairs. Results: No difference was observed in the incidence of postinterventional pneumonia (p = 0.148). The occurrence of myocardial infarction (p = 0.2) and stroke (p = 0.4) also did not differ significantly between the two groups. In contrast, the need for transient renal replacement therapy (p = 0.02) and 30-day mortality (p = 0.02) were lower in the analgosedation group. Conclusions: Regarding postinterventional pneumonia, general anaesthesia can be used as safely as analgosedation during TAVI. However, since renal failure requiring temporary replacement therapy and mortality are both increased with general anaesthesia, analgosedation should be the standard of care for TAVI in high-volume centers. The anesthetic regimen must be determined on an individual basis and discussed during the heart team briefing. The conversion to, or primary use of, general anaesthesia when clinically indicated is safe. Overall, ensuring the continuous presence of a senior consultant anesthetist, specifically trained in cardiac anaesthesia, throughout the procedure is essential.
- 26 May 2026
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 27 (5)
Open AccessGeneral Anaesthesia Versus Conscious Sedation in Transcatheter Aortic Valve Implantation: Differences in Pulmonary Infections
Background: Patients undergoing transfemoral aortic valve replacement are particularly vulnerable and require a more sophisticated anesthetic therapeutic approach. According to the literature, no study has directly compared general anaesthesia with conscious analgosedation using postoperative infections as the primary endpoint. Methods: Patients undergoing transcatheter aortic valve implantation (TAVI) were analyzed retrospectively. A total of 3313 patients from a large heart center in Western Europe were included in this study. One group received general anaesthesia, and the other group received analgosedation for TAVI. The primary outcome was postinterventional pneumonia; secondary outcomes included myocardial infarction, renal failure, stroke, and 30-day mortality. Propensity score matching using 16 matching criteria yielded over 1000 pairs. Results: No difference was observed in the incidence of postinterventional pneumonia (p = 0.148). The occurrence of myocardial infarction (p = 0.2) and stroke (p = 0.4) also did not differ significantly between the two groups. In contrast, the need for transient renal replacement therapy (p = 0.02) and 30-day mortality (p = 0.02) were lower in the analgosedation group. Conclusions: Regarding postinterventional pneumonia, general anaesthesia can be used as safely as analgosedation during TAVI. However, since renal failure requiring temporary replacement therapy and mortality are both increased with general anaesthesia, analgosedation should be the standard of care for TAVI in high-volume centers. The anesthetic regimen must be determined on an individual basis and discussed during the heart team briefing. The conversion to, or primary use of, general anaesthesia when clinically indicated is safe. Overall, ensuring the continuous presence of a senior consultant anesthetist, specifically trained in cardiac anaesthesia, throughout the procedure is essential.
- Open Access
- 26 May 2026
- Vol. 27 (5)
General Anaesthesia Versus Conscious Sedation in Transcatheter Aortic Valve Implantation: Differences in Pulmonary Infections
Patients undergoing transfemoral aortic valve replacement are particularly vulnerable and require a more sophisticated anesthetic therapeutic approach. According to the literature, no study has directly compared general anaesthesia with conscious analgosedation using postoperative infections as the primary endpoint. Patients undergoing transcatheter aortic valve implantation (TAVI) were analyzed retrospectively. A total of 3313 patients from a large heart center in Western Europe were included in this study. One group received general anaesthesia, and the other group received analgosedation for TAVI. The primary outcome was postinterventional pneumonia; secondary outcomes included myocardial infarction, renal failure, stroke, and 30-day mortality. Propensity score matching using 16 matching criteria yielded over 1000 pairs. No difference was observed in the incidence of postinterventional pneumonia (p = 0.148). The occurrence of myocardial infarction (p = 0.2) and stroke (p = 0.4) also did not differ significantly between the two groups. In contrast, the need for transient renal replacement therapy (p = 0.02) and 30-day mortality (p = 0.02) were lower in the analgosedation group. Regarding postinterventional pneumonia, general anaesthesia can be used as safely as analgosedation during TAVI. However, since renal failure requiring temporary replacement therapy and mortality are both increased with general anaesthesia, analgosedation should be the standard of care for TAVI in high-volume centers. The anesthetic regimen must be determined on an individual basis and discussed during the heart team briefing. The conversion to, or primary use of, general anaesthesia when clinically indicated is safe. Overall, ensuring the continuous presence of a senior consultant anesthetist, specifically trained in cardiac anaesthesia, throughout the procedure is essential.
- 26 May 2026
- Vol. 27 (5)
Open AccessGeneral Anaesthesia Versus Conscious Sedation in Transcatheter Aortic Valve Implantation: Differences in Pulmonary Infections
Patients undergoing transfemoral aortic valve replacement are particularly vulnerable and require a more sophisticated anesthetic therapeutic approach. According to the literature, no study has directly compared general anaesthesia with conscious analgosedation using postoperative infections as the primary endpoint. Patients undergoing transcatheter aortic valve implantation (TAVI) were analyzed retrospectively. A total of 3313 patients from a large heart center in Western Europe were included in this study. One group received general anaesthesia, and the other group received analgosedation for TAVI. The primary outcome was postinterventional pneumonia; secondary outcomes included myocardial infarction, renal failure, stroke, and 30-day mortality. Propensity score matching using 16 matching criteria yielded over 1000 pairs. No difference was observed in the incidence of postinterventional pneumonia (p = 0.148). The occurrence of myocardial infarction (p = 0.2) and stroke (p = 0.4) also did not differ significantly between the two groups. In contrast, the need for transient renal replacement therapy (p = 0.02) and 30-day mortality (p = 0.02) were lower in the analgosedation group. Regarding postinterventional pneumonia, general anaesthesia can be used as safely as analgosedation during TAVI. However, since renal failure requiring temporary replacement therapy and mortality are both increased with general anaesthesia, analgosedation should be the standard of care for TAVI in high-volume centers. The anesthetic regimen must be determined on an individual basis and discussed during the heart team briefing. The conversion to, or primary use of, general anaesthesia when clinically indicated is safe. Overall, ensuring the continuous presence of a senior consultant anesthetist, specifically trained in cardiac anaesthesia, throughout the procedure is essential.
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 2026 (1)
Patient‐Reported Health‐Related Quality of Life One Year After Transcatheter Aortic Valve Implantation: A Single‐Center Prospective Observational Registry Study
Background: Transcatheter aortic valve implantation (TAVI) is increasingly performed, yet long‐term patient‐reported outcomes (PROs) and health‐related quality of life (HR‐QoL) remain insufficiently characterized. Identifying factors associated with HR‐QoL may contribute to patient‐centered care. This study aimed to identify demographic and perioperative factors associated with physical and mental HR‐QoL at 1‐year follow‐up after TAVI. Methods: Among 337 patients undergoing TAVI, 211 1‐year survivors with complete 12‐Item Short Form Health Survey (SF‐12) constituted the analytical cohort. A frailty‐ and delirium‐screened subgroup comprised 112 patients. HR‐QoL at 1 year was assessed using the Physical Component Summary (PCS) and Mental Component Summary (MCS) of the SF‐12. Associations between demographic and perioperative variables and 1‐year PCS and MCS were evaluated using multivariable linear regression models. Results: The mean age was 83.3 years, and 42.2% were female. One‐year mortality was 7.7% (26/337). Older age (B −9.5, 95% confidence interval (CI) −14.8 to −4.2, p < 0.001), anemia (B −4.2, 95% CI −8.1 to −0.4, p = 0.030), obesity (B −5.4, 95% CI −9.4 to −1.4, p = 0.009), smoking (B −7.9, 95% CI −13.6 to −2.2, p = 0.007), and higher symptom burden (B −14.6, 95% CI −23.7 to −5.6, p = 0.002) were associated with lower PCS, as was physical frailty (B −7.4, 95% CI −14.2 to −0.6, p = 0.032). Female sex (B −4.1, 95% CI −7.5 to −0.7, p = 0.019), preexisting diabetes mellitus (B −4.0, 95% CI −7.7 to −0.3, p = 0.033) and physical prefrailty (B −5.9, 95% CI −11.4 to −0.5, p = 0.034) were associated with lower MCS. Conclusions: Among 1‐year survivors, several demographic and clinical characteristics, including physical frailty, were independently associated with lower HR‐QoL scores. These associations are conditional on survival and questionnaire completion and may therefore be affected by survivorship and response selection, as well as the absence of baseline HR‐QoL assessment.
- 1 January 2026
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 2026 (1)
Open AccessPatient‐Reported Health‐Related Quality of Life One Year After Transcatheter Aortic Valve Implantation: A Single‐Center Prospective Observational Registry Study
Background: Transcatheter aortic valve implantation (TAVI) is increasingly performed, yet long‐term patient‐reported outcomes (PROs) and health‐related quality of life (HR‐QoL) remain insufficiently characterized. Identifying factors associated with HR‐QoL may contribute to patient‐centered care. This study aimed to identify demographic and perioperative factors associated with physical and mental HR‐QoL at 1‐year follow‐up after TAVI. Methods: Among 337 patients undergoing TAVI, 211 1‐year survivors with complete 12‐Item Short Form Health Survey (SF‐12) constituted the analytical cohort. A frailty‐ and delirium‐screened subgroup comprised 112 patients. HR‐QoL at 1 year was assessed using the Physical Component Summary (PCS) and Mental Component Summary (MCS) of the SF‐12. Associations between demographic and perioperative variables and 1‐year PCS and MCS were evaluated using multivariable linear regression models. Results: The mean age was 83.3 years, and 42.2% were female. One‐year mortality was 7.7% (26/337). Older age (B −9.5, 95% confidence interval (CI) −14.8 to −4.2, p < 0.001), anemia (B −4.2, 95% CI −8.1 to −0.4, p = 0.030), obesity (B −5.4, 95% CI −9.4 to −1.4, p = 0.009), smoking (B −7.9, 95% CI −13.6 to −2.2, p = 0.007), and higher symptom burden (B −14.6, 95% CI −23.7 to −5.6, p = 0.002) were associated with lower PCS, as was physical frailty (B −7.4, 95% CI −14.2 to −0.6, p = 0.032). Female sex (B −4.1, 95% CI −7.5 to −0.7, p = 0.019), preexisting diabetes mellitus (B −4.0, 95% CI −7.7 to −0.3, p = 0.033) and physical prefrailty (B −5.9, 95% CI −11.4 to −0.5, p = 0.034) were associated with lower MCS. Conclusions: Among 1‐year survivors, several demographic and clinical characteristics, including physical frailty, were independently associated with lower HR‐QoL scores. These associations are conditional on survival and questionnaire completion and may therefore be affected by survivorship and response selection, as well as the absence of baseline HR‐QoL assessment.
- Open Access
Advanced Haemodynamic Monitoring During Transfemoral Aortic Valve Replacement: A Prospective Pilot Study
This pilot study aims to compare advanced and standard haemodynamic monitoring during TAVI in terms of predicting and avoiding hypotension. Intraoperative hypotension influences postoperative outcomes by increasing mortality, renal failure, and cardiac complications. In TAVI (transaortic valve implantation), haemodynamic stability is essential because the patients are usually old and vulnerable. Fifty patients underwent transfemoral TAVI under standard anaesthetic care. Blood pressure was measured invasively, using Edwards Acumen sensors connected to a HemoSphere monitor. The signal was simultaneously fed to anaesthesia monitors. Patients were randomly divided into two groups: in the test group, the Edwards monitor with the HPI (hypotension prediction index) values was available to the anaesthetist, whereas in the control group, the HemoSphere monitor was covered. The primary endpoint of the study was the time-weighted average of intraoperative hypotension, which is calculated from the intensity and duration of hypotension, adjusted for the duration of surgery (TWA65). Secondary endpoints were the cumulative time of hypotensive episodes adjusted for the duration of the procedure (TWAtotal). No difference in intraoperative hypotension in terms of TWA65 between control and intervention group could be detected, the overall duration of intraoperative hypotension was reduced in the intervention group, and the administration of intraoperative volume was higher in the intervention group when compared to controls. The use of HPI during TAVI leads to improved haemodynamic stability, and this is particularly important in these extremely vulnerable patients. Not only is it possible to reduce overall intraoperative hypotension with HPI, but postoperative complications associated with intraoperative hypotension that might occur will also be diminished.
Open AccessAdvanced Haemodynamic Monitoring During Transfemoral Aortic Valve Replacement: A Prospective Pilot Study
This pilot study aims to compare advanced and standard haemodynamic monitoring during TAVI in terms of predicting and avoiding hypotension. Intraoperative hypotension influences postoperative outcomes by increasing mortality, renal failure, and cardiac complications. In TAVI (transaortic valve implantation), haemodynamic stability is essential because the patients are usually old and vulnerable. Fifty patients underwent transfemoral TAVI under standard anaesthetic care. Blood pressure was measured invasively, using Edwards Acumen sensors connected to a HemoSphere monitor. The signal was simultaneously fed to anaesthesia monitors. Patients were randomly divided into two groups: in the test group, the Edwards monitor with the HPI (hypotension prediction index) values was available to the anaesthetist, whereas in the control group, the HemoSphere monitor was covered. The primary endpoint of the study was the time-weighted average of intraoperative hypotension, which is calculated from the intensity and duration of hypotension, adjusted for the duration of surgery (TWA65). Secondary endpoints were the cumulative time of hypotensive episodes adjusted for the duration of the procedure (TWAtotal). No difference in intraoperative hypotension in terms of TWA65 between control and intervention group could be detected, the overall duration of intraoperative hypotension was reduced in the intervention group, and the administration of intraoperative volume was higher in the intervention group when compared to controls. The use of HPI during TAVI leads to improved haemodynamic stability, and this is particularly important in these extremely vulnerable patients. Not only is it possible to reduce overall intraoperative hypotension with HPI, but postoperative complications associated with intraoperative hypotension that might occur will also be diminished.
- Open Access
Comparison of DeltaScan® and CAM-ICU for the Assessment of Postoperative Delirium in Patients Undergoing Cardiac Surgery and Cardiac Interventions: A Prospective Observational Pilot Study
Background: Postoperative delirium is frequent among elderly patients and often presents after major surgery or intervention. Validated screening tools should be routinely used to recognise this psychopathological syndrome. Delirium might be associated with systematic changes in brain network organisation, including reduced EEG connectivity. Methods: This observational single-centre pilot study aimed to evaluate the agreement between DeltaScan® (Prolira BV, Utrecht, The Netherlands) and CAM-ICU screening in detecting postoperative delirium in patients undergoing cardiac surgery or cardiac intervention. Results: 1. Patients showing delirium have DeltaScan® scores ≥ 3. 2. Patients scoring ≥ 3 in the DeltaScan® examination do not necessarily show signs of delirium in CAM-ICU testing. 3. All patients showing delirium in CAM-ICU testing have pathological clock-drawing results. Conclusions: DeltaScan® reliably detects delta wave abnormalities associated with delirium, though some patients with increased delta activity did not exhibit clinically manifest delirium.
Open AccessComparison of DeltaScan® and CAM-ICU for the Assessment of Postoperative Delirium in Patients Undergoing Cardiac Surgery and Cardiac Interventions: A Prospective Observational Pilot Study
Background: Postoperative delirium is frequent among elderly patients and often presents after major surgery or intervention. Validated screening tools should be routinely used to recognise this psychopathological syndrome. Delirium might be associated with systematic changes in brain network organisation, including reduced EEG connectivity. Methods: This observational single-centre pilot study aimed to evaluate the agreement between DeltaScan® (Prolira BV, Utrecht, The Netherlands) and CAM-ICU screening in detecting postoperative delirium in patients undergoing cardiac surgery or cardiac intervention. Results: 1. Patients showing delirium have DeltaScan® scores ≥ 3. 2. Patients scoring ≥ 3 in the DeltaScan® examination do not necessarily show signs of delirium in CAM-ICU testing. 3. All patients showing delirium in CAM-ICU testing have pathological clock-drawing results. Conclusions: DeltaScan® reliably detects delta wave abnormalities associated with delirium, though some patients with increased delta activity did not exhibit clinically manifest delirium.