Yajie Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yajie Zhao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Fei Lin
2 shared publications- Fei Lin
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100014, China
2 shared publications - Zhihong Zhong
School of Electrical Engineering, Beijing Jiaotong University, Beijing, China
2 shared publications Zhongping Yang
2 shared publications- Jiayu Mi
School of Electrical Engineering, Beijing Jiaotong University, Beijing, China
1 shared publication Jingpeng Zhang
1 shared publication
Latest Publications
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Fast Quasi-Optimal Control of On-Board Energy Storage Systems for Regenerative Braking Energy Recovery Based on Area-Equivalence Principle
Existing threshold-based control strategies for on-board energy storage systems (OESSs) often fail to achieve optimal energy-saving performance, while AI-based strategies typically suffer from low computational efficiency. To address these limitations, this article proposes a fast quasi-optimal control strategy for OESSs by leveraging the electrical characteristics of supercapacitors and the area-equivalence principle. Specifically, during train braking, OESSs should absorb as much regenerative braking energy as possible. By applying the area-equivalence principle, this goal is reformulated as a geometric problem-maximizing the area bounded by the train power curve and the OESS power curve. Thus, the optimal charging current and initial charging voltage of OESSs can be determined. Correspondingly, a discharging strategy is developed to ensure that the OESS voltage at the end of train traction reaches the previously obtained optimal initial charging voltage. Case studies reveal that the proposed area-equivalent strategy can achieve 98% of the optimal energy-saving performance while maintaining low root-mean-square (rms) current and average di/dt. Meanwhile, its computational time is only 1/92 of that of dynamic programming (DP) method. With a well-balanced trade-off among energy recovery performance, computational efficiency, and OESS lifetime, the superiority of the area-equivalence-based control strategy is verified.
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Fast Quasi-Optimal Control of On-Board Energy Storage Systems for Regenerative Braking Energy Recovery Based on Area-Equivalence Principle
Existing threshold-based control strategies for on-board energy storage systems (OESSs) often fail to achieve optimal energy-saving performance, while AI-based strategies typically suffer from low computational efficiency. To address these limitations, this article proposes a fast quasi-optimal control strategy for OESSs by leveraging the electrical characteristics of supercapacitors and the area-equivalence principle. Specifically, during train braking, OESSs should absorb as much regenerative braking energy as possible. By applying the area-equivalence principle, this goal is reformulated as a geometric problem-maximizing the area bounded by the train power curve and the OESS power curve. Thus, the optimal charging current and initial charging voltage of OESSs can be determined. Correspondingly, a discharging strategy is developed to ensure that the OESS voltage at the end of train traction reaches the previously obtained optimal initial charging voltage. Case studies reveal that the proposed area-equivalent strategy can achieve 98% of the optimal energy-saving performance while maintaining low root-mean-square (rms) current and average di/dt. Meanwhile, its computational time is only 1/92 of that of dynamic programming (DP) method. With a well-balanced trade-off among energy recovery performance, computational efficiency, and OESS lifetime, the superiority of the area-equivalence-based control strategy is verified.
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (4) , 6963-6973
Vehicle-Operation-Driven Capacity Optimization and Dynamic Control of Urban Rail Transit Energy Storage Systems
This study proposes a novel two-stage optimization architecture (TSOA) for ultracapacitor energy storage systems (UCESS) in urban rail transit systems (URTS), aiming to enhance both economic returns and operational performance simultaneously. In the design phase, a swarm intelligence-based Cheetah Algorithm (CA) is employed to optimize UCESS capacity allocation alongside vehicle dwell time scheduling. During the operational phase, the system leverages these pre-optimized parameters to plan the state-of-energy (SOE) trajectory, ensuring precise real-time coordination between UCESS and vehicle demand. Simulation results indicate substantial improvements: the levelized cost of electricity (LCOE) decreases from 0.56 to 0.42 yuan/kWh compared with standalone UCESS optimization. Additionally, the TSOA elevates average energy savings of 6.12% and 4.07%, comparing the traditional fixed-threshold strategy (TFT-EMS) and the genetic algorithm-optimized fixed-threshold strategy (GAFT-EMS), respectively. Validation through a 1.5 MW engineering prototype implemented in a Chinese subway system confirmed these benefits, demonstrating practical average energy savings of 5.46% and 3.54% over TFT-EMS and GAFT-EMS. The proposed architecture exhibits broad applicability, independent of city, line, or passenger flow characteristics. It provides valuable guidance for promoting green transformation and low-carbon development in URTS through large-scale deployment of UCESS.
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (4) , 6963-6973
Vehicle-Operation-Driven Capacity Optimization and Dynamic Control of Urban Rail Transit Energy Storage Systems
This study proposes a novel two-stage optimization architecture (TSOA) for ultracapacitor energy storage systems (UCESS) in urban rail transit systems (URTS), aiming to enhance both economic returns and operational performance simultaneously. In the design phase, a swarm intelligence-based Cheetah Algorithm (CA) is employed to optimize UCESS capacity allocation alongside vehicle dwell time scheduling. During the operational phase, the system leverages these pre-optimized parameters to plan the state-of-energy (SOE) trajectory, ensuring precise real-time coordination between UCESS and vehicle demand. Simulation results indicate substantial improvements: the levelized cost of electricity (LCOE) decreases from 0.56 to 0.42 yuan/kWh compared with standalone UCESS optimization. Additionally, the TSOA elevates average energy savings of 6.12% and 4.07%, comparing the traditional fixed-threshold strategy (TFT-EMS) and the genetic algorithm-optimized fixed-threshold strategy (GAFT-EMS), respectively. Validation through a 1.5 MW engineering prototype implemented in a Chinese subway system confirmed these benefits, demonstrating practical average energy savings of 5.46% and 3.54% over TFT-EMS and GAFT-EMS. The proposed architecture exhibits broad applicability, independent of city, line, or passenger flow characteristics. It provides valuable guidance for promoting green transformation and low-carbon development in URTS through large-scale deployment of UCESS.