Owain Griffiths
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Owain Griffiths has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
A. Caffrey
2 shared publications- A. J. Boston
University of Liverpool L69 3BX Liverpool United Kingdom
2 shared publications - D. S. Judson
University of Liverpool
2 shared publications - Ellis Rintoul
University of Liverpool
2 shared publications - L. J. Harkness-Brennan
University of Liverpool
2 shared publications Ahmed Alharbi
Department of Physics, College of Science, Qassim University, Buraydah, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09050
Three-dimensional gamma-ray imaging and mapping using the transportable GRI+ Compton camera
The GRI+ system is a transportable, multi-tiered Compton γ-imaging system developed for radiation localisation and mapping in challenging nuclear decommissioning environments. Combining electrically cooled and position-sensitive Si(Li) and HPGe detectors with pulse shape analysis and γ-tracking methodologies, the system delivers high spectroscopic performance and three-dimensional imaging across a wide field of view at large stand-off distances. This work presents the first demonstration of three-dimensional Compton imaging with the GRI+ system at stand-off distances of up to 5 m, combined with interactive spatial and spectral investigation of complex scenes through fusion with LIDAR data. The system enables localisation and characterisation of point-like and distributed γ sources in multi-source and off-axis radiation environments that are representative of nuclear decommissioning scenarios. Imaging results are presented using an interactive application that provides energy gating, spatial gating, thresholding, and further controls that support scene investigation. During live imaging of a 137 Cs source at 5 m stand-off, the system achieves an angular resolution of 5.65 ∘ and an intrinsic imaging efficiency of 0.05% when operated in maximum-resolution analysis mode, and of 7.84 ∘ and 0.13% when operated in maximum-efficiency mode. GRI+ is shown to effectively characterise and localise both point-like and distributed sources and to perform well in environments with off-axis radiation sources. Spatial selection of contaminants is demonstrated as an effective tool for source identification and characterisation, rejecting 99.31% of counts originating from a secondary source. These findings establish the capability of the system to provide accurate spatial reconstruction suitable for large-scale nuclear decommissioning tasks, with future developments directed toward enabling virtual-reality integration and full-scene activity estimation.
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09050
Open AccessThree-dimensional gamma-ray imaging and mapping using the transportable GRI+ Compton camera
The GRI+ system is a transportable, multi-tiered Compton γ-imaging system developed for radiation localisation and mapping in challenging nuclear decommissioning environments. Combining electrically cooled and position-sensitive Si(Li) and HPGe detectors with pulse shape analysis and γ-tracking methodologies, the system delivers high spectroscopic performance and three-dimensional imaging across a wide field of view at large stand-off distances. This work presents the first demonstration of three-dimensional Compton imaging with the GRI+ system at stand-off distances of up to 5 m, combined with interactive spatial and spectral investigation of complex scenes through fusion with LIDAR data. The system enables localisation and characterisation of point-like and distributed γ sources in multi-source and off-axis radiation environments that are representative of nuclear decommissioning scenarios. Imaging results are presented using an interactive application that provides energy gating, spatial gating, thresholding, and further controls that support scene investigation. During live imaging of a 137 Cs source at 5 m stand-off, the system achieves an angular resolution of 5.65 ∘ and an intrinsic imaging efficiency of 0.05% when operated in maximum-resolution analysis mode, and of 7.84 ∘ and 0.13% when operated in maximum-efficiency mode. GRI+ is shown to effectively characterise and localise both point-like and distributed sources and to perform well in environments with off-axis radiation sources. Spatial selection of contaminants is demonstrated as an effective tool for source identification and characterisation, rejecting 99.31% of counts originating from a secondary source. These findings establish the capability of the system to provide accurate spatial reconstruction suitable for large-scale nuclear decommissioning tasks, with future developments directed toward enabling virtual-reality integration and full-scene activity estimation.
- 18 October 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 227, 112262
Assessing the impact of position resolution on gamma-ray imaging performance of a Segmented Inverted Coaxial Germanium (SIGMA) detector
- 18 October 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 227, 112262
Assessing the impact of position resolution on gamma-ray imaging performance of a Segmented Inverted Coaxial Germanium (SIGMA) detector