Jessica Schrapers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jessica Schrapers has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Julius Ridder
University Center of Cardiovascular Science (UCCS), University Medical Center Hamburg-Eppendorf (UKE), Hamburg, Germany
3 shared publications - Justus Stenzig
German Center for Cardiovascular Research (DZHK), Partner Site North, Hamburg, Germany
3 shared publications - Larissa Fabritz
Department of Cardiology, University Heart & Vascular Centre Hamburg, University Medical Centre Hamburg-Eppendorf , Hamburg
3 shared publications - Marc Nikolaus Hirt
University Center of Cardiovascular Science (UCCS), University Medical Center Hamburg-Eppendorf (UKE), Hamburg, Germany
3 shared publications - Thomas Eschenhagen
German Center for Cardiovascular Research (DZHK), Partner Site North, Hamburg, Germany
3 shared publications - Aaltje Maria Stella Stoter
Department of Experimental Pharmacology and Toxicology, University Medical Center Hamburg-Eppendorf , Martinistrasse 52, 20246 Hamburg
2 shared publications
Latest Publications
- Open Access
Dynamic BMP10 Release Reflects Atrial Fibrillation Burden in Human Atrial Engineered Heart Tissue
Background: Atrial fibrillation (AF) burden is increasingly recognized as a determinant of clinical risk. Currently, AF burden can only be estimated using long-term rhythm monitoring. Bone morphogenetic protein 10 (BMP10) is a protein secreted from cardiac atria associated with AF and AF-related complications. This study evaluated whether BMP10 concentrations are associated with AF burden in a human atrial model: atrial engineered heart tissue (aEHT). Methods: Human induced pluripotent stem cell-derived atrial cardiomyocytes were cast into atrial engineered heart tissues (aEHTs). To mimic AF burden, mature aEHTs were optogenetically-paced at a high rate of 4 Hz, either intermittently for 4 hours every 2 days (∼10% burden) or continuously for 24 hours per day (100% burden). After 18 days of high-rate pacing intervention, 7 days of recovery without pacing followed. BMP10 release was quantified by ELISA and contractile function was assessed by video analysis. EHT transcriptional remodeling in response to mimicked AF burden was assessed by RNA sequencing and the effect of recovery was analyzed by qPCR. Results: High-rate optogenetic pacing mimicking AF lead to a dynamic, burden-dependent BMP10 release: BMP10 concentrations in the medium were increased by intermittent optogenetic pacing (∼10% burden) and highest under continuous optogenetic pacing (100% burden). BMP10 release declined toward control levels during recovery. Contractile dysfunction was most impaired after continuous pacing and showed only partial recovery within 1 days after pacing cessation. RNA sequencing revealed distinct burden-dependent transcriptional states. Pacing-regulated transcripts were related to BMP/TGFβ signaling, atrial identity, calcium handling, contractile phenotype, and electrophysiological remodeling. After recovery, BMP10 mRNA expression remained elevated despite normalization of BMP10 protein release. Conclusions: AF burden dynamically regulates BMP10 release and functional and molecular remodeling in human aEHTs. BMP10 release depicts a secreted protein-based readout of current or recent atrial high-rate stress, whereas persistent transcriptional changes indicate molecular memory of prior AF burden. These findings support BMP10 release as a burden-sensitive AF biomarker. Graphical Clinical Perspective: The secreted bone morphogenetic protein 10 (BMP10) is an emerging blood biomarker associated with atrial fibrillation (AF) and its complications. Continuous atrial high-rate pacing leads to BMP10 release in atrial engineered heart tissues (aEHTs). BMP10 release and BMP10 mRNA expression mirrors varying AF burden in aEHT and even ∼10% burden leads to significantly increased BMP10 mRNA expression and protein release. After returning to normal rate, BMP10 release decreases to baseline within 7 days, while BMP10 mRNA expression shows a delayed response. BMP10 may qualify as an AF burden-sensitive, circulating biomarker for AF and burden-associated outcome prediction.
Open AccessDynamic BMP10 Release Reflects Atrial Fibrillation Burden in Human Atrial Engineered Heart Tissue
Background: Atrial fibrillation (AF) burden is increasingly recognized as a determinant of clinical risk. Currently, AF burden can only be estimated using long-term rhythm monitoring. Bone morphogenetic protein 10 (BMP10) is a protein secreted from cardiac atria associated with AF and AF-related complications. This study evaluated whether BMP10 concentrations are associated with AF burden in a human atrial model: atrial engineered heart tissue (aEHT). Methods: Human induced pluripotent stem cell-derived atrial cardiomyocytes were cast into atrial engineered heart tissues (aEHTs). To mimic AF burden, mature aEHTs were optogenetically-paced at a high rate of 4 Hz, either intermittently for 4 hours every 2 days (∼10% burden) or continuously for 24 hours per day (100% burden). After 18 days of high-rate pacing intervention, 7 days of recovery without pacing followed. BMP10 release was quantified by ELISA and contractile function was assessed by video analysis. EHT transcriptional remodeling in response to mimicked AF burden was assessed by RNA sequencing and the effect of recovery was analyzed by qPCR. Results: High-rate optogenetic pacing mimicking AF lead to a dynamic, burden-dependent BMP10 release: BMP10 concentrations in the medium were increased by intermittent optogenetic pacing (∼10% burden) and highest under continuous optogenetic pacing (100% burden). BMP10 release declined toward control levels during recovery. Contractile dysfunction was most impaired after continuous pacing and showed only partial recovery within 1 days after pacing cessation. RNA sequencing revealed distinct burden-dependent transcriptional states. Pacing-regulated transcripts were related to BMP/TGFβ signaling, atrial identity, calcium handling, contractile phenotype, and electrophysiological remodeling. After recovery, BMP10 mRNA expression remained elevated despite normalization of BMP10 protein release. Conclusions: AF burden dynamically regulates BMP10 release and functional and molecular remodeling in human aEHTs. BMP10 release depicts a secreted protein-based readout of current or recent atrial high-rate stress, whereas persistent transcriptional changes indicate molecular memory of prior AF burden. These findings support BMP10 release as a burden-sensitive AF biomarker. Graphical Clinical Perspective: The secreted bone morphogenetic protein 10 (BMP10) is an emerging blood biomarker associated with atrial fibrillation (AF) and its complications. Continuous atrial high-rate pacing leads to BMP10 release in atrial engineered heart tissues (aEHTs). BMP10 release and BMP10 mRNA expression mirrors varying AF burden in aEHT and even ∼10% burden leads to significantly increased BMP10 mRNA expression and protein release. After returning to normal rate, BMP10 release decreases to baseline within 7 days, while BMP10 mRNA expression shows a delayed response. BMP10 may qualify as an AF burden-sensitive, circulating biomarker for AF and burden-associated outcome prediction.
- Open Access
- 4 August 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (8)
Optogenetic tachypacing facilitates burst-induced arrhythmia in stem cell-derived human atrial engineered heart tissue
Aims: Large animal models for atrial fibrillation (AF) research are ethically challenging and costly. Suitable humanized in vitro models could circumvent these problems. Here, we aimed to combine tissue engineering, human induced pluripotent stem cell-derived atrial cardiomyocytes (hiPSC-aCM), and optogenetic pacing to trigger an in vitro fibrillation-like state, which can be analysed by simple video recording. Methods and results: Atrial engineered heart tissue (aEHT) was created from hiPSC-aCM and transduced with adeno-associated virus vectors to express the channelrhodopsins CheRiff2.0, Chronos, or PsCatCh2.0f, respectively. We developed novel optogenetic hardware, based on microcontroller programmable light-emitting diodes. The interplay between aEHTs and hardware was optimized, and different pacing patterns were evaluated. Electrical burst pacing was evaluated for arrhythmia induction. Tissue constructs were analysed with regard to action potential, gene and protein expression, and structure. We found our optimized CheRiff2.0 best suitable for optogenetic pacing of aEHT at up to 5 Hz. Atrial EHT could be faithfully tachypaced at 4 Hz for 2.5 weeks. After 5 weeks, electrical burst pacing (20 Hz, 0.5 s) successfully induced self-sustained episodes of a state of fast beating, lower force, and incomplete relaxation. The propensity of these burst-evoked episodes of fibrillation was 3.2-fold higher in long-term paced aEHT than in non-paced controls. Action potential shape and gene expression recapitulated typical features of AF in the tachypaced aEHTs. Conclusion: We successfully created a first-of-its-kind in vitro model of AF, recapitulating the self-sustainability of atrial arrhythmia (‘AF begets AF’). Fibrillation-like episodes can be verified by visual inspection, rendering analysis possible without an electrophysiological setup.
- 4 August 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (8)
Open AccessOptogenetic tachypacing facilitates burst-induced arrhythmia in stem cell-derived human atrial engineered heart tissue
Aims: Large animal models for atrial fibrillation (AF) research are ethically challenging and costly. Suitable humanized in vitro models could circumvent these problems. Here, we aimed to combine tissue engineering, human induced pluripotent stem cell-derived atrial cardiomyocytes (hiPSC-aCM), and optogenetic pacing to trigger an in vitro fibrillation-like state, which can be analysed by simple video recording. Methods and results: Atrial engineered heart tissue (aEHT) was created from hiPSC-aCM and transduced with adeno-associated virus vectors to express the channelrhodopsins CheRiff2.0, Chronos, or PsCatCh2.0f, respectively. We developed novel optogenetic hardware, based on microcontroller programmable light-emitting diodes. The interplay between aEHTs and hardware was optimized, and different pacing patterns were evaluated. Electrical burst pacing was evaluated for arrhythmia induction. Tissue constructs were analysed with regard to action potential, gene and protein expression, and structure. We found our optimized CheRiff2.0 best suitable for optogenetic pacing of aEHT at up to 5 Hz. Atrial EHT could be faithfully tachypaced at 4 Hz for 2.5 weeks. After 5 weeks, electrical burst pacing (20 Hz, 0.5 s) successfully induced self-sustained episodes of a state of fast beating, lower force, and incomplete relaxation. The propensity of these burst-evoked episodes of fibrillation was 3.2-fold higher in long-term paced aEHT than in non-paced controls. Action potential shape and gene expression recapitulated typical features of AF in the tachypaced aEHTs. Conclusion: We successfully created a first-of-its-kind in vitro model of AF, recapitulating the self-sustainability of atrial arrhythmia (‘AF begets AF’). Fibrillation-like episodes can be verified by visual inspection, rendering analysis possible without an electrophysiological setup.
- Open Access
- 1 November 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (11) , e013834
High Rate Triggers Increased Atrial Release of BMP10, A Biomarker for Atrial Fibrillation and Stroke, and BMP10 Affects Ventricular Cardiomyocytes
BACKGROUND: BMP10 (bone morphogenetic protein 10) is a ligand of the TGF (transforming growth factor) β superfamily secreted mainly by atrial cardiomyocytes. Elevated BMP10 blood concentrations predict atrial fibrillation (AF), AF recurrence after ablation, and AF-related cardiovascular complications like stroke. The conditions increasing BMP10 secretion and the downstream effects of BMP10 in cardiomyocytes are poorly understood. We assessed BMP10 secretion dynamics and BMP10 effects in a human 3-dimensional model of atrial and ventricular engineered heart tissue (EHT). METHODS: Cardiomyocytes (atrial and ventricular) differentiated from human induced pluripotent stem cells were cast into a fibrin-matrix to generate EHT. Atrial EHTs were optogenetically paced (3–5 Hz) or maintained at intrinsic beating rate for 24 hours up to 15 days. Release of BMP10 and other cardiac biomarkers from EHT was quantified. BMP10 plasma concentrations were compared between 1370 patients with different atrial rhythms at blood draw. Additionally, ventricular EHTs were exposed to BMP10 for 10 days. RESULTS: Atrial but not ventricular EHT released BMP10 within 48 hours of culture. High-rate optogenetic pacing increased atrial EHT BMP10 release by ≈3-fold after a latency of at least 24 hours post initiation of pacing. BMP10 plasma concentrations were elevated in patients with documented AF compared with sinus rhythm and even higher in patients with current AF. BMP10 induced upregulation of TGFβ pathway transcripts, increased expression of genes related to AF and heart failure, including PITX2 and NPPB , and increased relative contraction times in ventricular EHTs. CONCLUSIONS: High atrial rates elevate BMP10 expression and release, and higher plasma concentrations of BMP10 are observed in patients with active AF. BMP10 exposure induces transcriptomic changes linked to AF and heart failure in ventricular EHT. These findings support BMP10 as a biomarker and potential mediator of AF-related remodeling and tachycardiomyopathy.
- 1 November 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (11) , e013834
Open AccessHigh Rate Triggers Increased Atrial Release of BMP10, A Biomarker for Atrial Fibrillation and Stroke, and BMP10 Affects Ventricular Cardiomyocytes
BACKGROUND: BMP10 (bone morphogenetic protein 10) is a ligand of the TGF (transforming growth factor) β superfamily secreted mainly by atrial cardiomyocytes. Elevated BMP10 blood concentrations predict atrial fibrillation (AF), AF recurrence after ablation, and AF-related cardiovascular complications like stroke. The conditions increasing BMP10 secretion and the downstream effects of BMP10 in cardiomyocytes are poorly understood. We assessed BMP10 secretion dynamics and BMP10 effects in a human 3-dimensional model of atrial and ventricular engineered heart tissue (EHT). METHODS: Cardiomyocytes (atrial and ventricular) differentiated from human induced pluripotent stem cells were cast into a fibrin-matrix to generate EHT. Atrial EHTs were optogenetically paced (3–5 Hz) or maintained at intrinsic beating rate for 24 hours up to 15 days. Release of BMP10 and other cardiac biomarkers from EHT was quantified. BMP10 plasma concentrations were compared between 1370 patients with different atrial rhythms at blood draw. Additionally, ventricular EHTs were exposed to BMP10 for 10 days. RESULTS: Atrial but not ventricular EHT released BMP10 within 48 hours of culture. High-rate optogenetic pacing increased atrial EHT BMP10 release by ≈3-fold after a latency of at least 24 hours post initiation of pacing. BMP10 plasma concentrations were elevated in patients with documented AF compared with sinus rhythm and even higher in patients with current AF. BMP10 induced upregulation of TGFβ pathway transcripts, increased expression of genes related to AF and heart failure, including PITX2 and NPPB , and increased relative contraction times in ventricular EHTs. CONCLUSIONS: High atrial rates elevate BMP10 expression and release, and higher plasma concentrations of BMP10 are observed in patients with active AF. BMP10 exposure induces transcriptomic changes linked to AF and heart failure in ventricular EHT. These findings support BMP10 as a biomarker and potential mediator of AF-related remodeling and tachycardiomyopathy.