KJKristen E. Jones

Kristen E. Jones

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kristen E. Jones has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction of proximal junctional failure using transforaminal thoracic interbody fusion: a technical note

    by Bryan Ladd, Kristen Jones, David Polly

    Objective:Proximal Junctional Failure (PJF) is a known complication of instrumented spine surgery. When a construct ends in the lower thoracic spine, PJF occurring at the suprajacent level can be difficult to adequately correct. Transforaminal Thoracic Interbody Fusion (TTIF) is a posterior-only pedicle-sparring approach that may offer effective correction of thoracic PJF.Methods:This report details a single-center retrospective review of patients who underwent TTIF for PJF correction from 2014-2020. Demographic data, operative details, and Oswestry Disability Index (ODI) was included for all patients with at least 1 year follow-up. Preoperative and postoperative full-spine radiographs were assessed for correction of proximal junctional kyphosis (PJK). Surgical complications were recorded.Results:A total of 22 patients underwent TTIF for PJF correction. Average kyphosis correction was 15° ± 10° (range 0° - 40°). All patients achieved correction to their physiologic sagittal alignment goals, except for one patient that experienced neuromonitoring changes during correction. All cases demonstrated arthrodesis. Mean ODI improvement at 1 year was 12.2% ± 20.0% (range -18.0% - 54.7%; p=0.048).Conclusions:TTIF is a viable and technically reproducible posterior-only approach for the surgical correction of thoracic PJF.

  • Open Access

    Osseous Engagement of Sacropelvic Porous Fusion–Fixation Screws

    by Jason J. Haselhuhn, David W. Polly, Todd J. Pottinger, Kari Odland, Jonathan N. Sembrano, Christopher T. Martin, Kristen E. Jones, Nathan R. Hendrickson

    (1) Background and introduction: High-demand lumbosacral fusions are often supplemented with sacral-alar-iliac (SAI) screws. The idealized SAI trajectory was estimated to traverse 35 mm of sacrum before crossing the sacroiliac (SI) joint. However, there is debate on how much osseous purchase SAI screws achieve. The goal of this study was to determine the amount of osseous engagement achieved using a porous fusion–fixation screw (PFFS) when placed in a stacked SAI configuration. (2) Materials and methods: We retrospectively reviewed 40 consecutive patients who underwent sacropelvic fixation with stacked PFFS at our institution from 1 June 2022 to 30 June 2023, using intraoperative computed tomography (CT)-based computer navigation. A snapshot of each screw was taken and the length of purchase within the sacrum and ilium was measured on the axial image along the anterior and posterior aspect of each screw. Nineteen patients did not have adequate images available for review and were excluded. (3) Results: The overall mean anterior sacral engagement was 38.6 mm (±8.2 mm), which was found to be statistically significantly greater than the hypothesized threshold of 35 mm (p < 0.001), while posterior sacral engagement was 28.1 mm (±8.6 mm), which was not found to be statistically significantly greater than the hypothesized threshold of 35 mm (p = 1). The mean difference in sacral engagement between the anatomical location for the cephalad screws was 10.3 mm (p < 0.001) and 10.6 mm (p < 0.001) for the caudal screws. The total sacral surface area available for bone ingrowth for bilateral stacked PFFS was calculated to be 3338.3 mm2, while the total iliac surface area available for bone ingrowth was 4364.8 mm2. A mean difference in surface area availability between anatomical locations was −689.5 mm2 (p < 0.001) for the sacrum and 689.5 mm2 (p < 0.001) for the ilium. (4) Discussion and conclusions: The SAI trajectory screws in this cohort of patients achieved approximately 39 mm of sacrum engagement anteriorly and 28 mm posteriorly. This is consistent with prior estimates based on the idealized SAI pathway through the sacrum. PFFSs allow for simultaneous sacropelvic fixation and SI joint fusion, which may reduce the incidence of de novo SI joint pain in patients with long fusion constructs.

  • Open Access

    Prospective Real-Time Screw Placement Using O-Arm Navigation

    by David W. Polly, Kenneth J. Holton, Paul Brian O. Soriano, Jason J. Haselhuhn, Kari Odland, Jonathan N. Sembrano, Christopher T. Martin, Kristen E. Jones

    Background/Objectives: A variety of techniques for pedicle screw placement exist. Efficiency claims have varied, but limited data are available to support or refute these claims. Our goal was to study our screw placement efficiency, reporting real-time screw placement using O-arm 3D navigation. Methods: We prospectively enrolled patients from July 2019 to February 2022 who were undergoing primary procedures involving thoracolumbar pedicle and pelvic screw placement with O-arm navigation. Screw time began at the first placement of the navigated probe/awl and ended once the navigated screwdriver was removed from the screw head. Confirmatory 3D scans were performed to assess all screw placements. Results: The real-time average to place pedicle screws was 2 min 9 s (SD ± 1 min 5 s); for pelvic screws, this was 3 min 36 s. Screw placement was slightly faster in pediatric patients (2 min 3 s) vs. adults (2 min 24 s), p < 0.001. Screw placement was faster in the thoracic spine (2 min 2 s) vs. the lumbosacral spine (2 min 22 s), p < 0.001. Screw placement was faster in adolescent idiopathic scoliosis (2 min 0 s) vs. all other diagnoses (2 min 24 s), p < 0.001. Screw placement performed by a single attending surgeon (2 min 24 s) was no different from dual-surgeon placement(2 min 13 s), p = 0.35. Conclusions: Our screw placement time is shorter than previously published estimates, and has a very high accuracy rate. While there are variations in how time is reported compared to the previous literature, our study serves as a benchmark for real-time screw placement for future studies. The use of navigation technology for pedicle and pelvic screw placement can be efficient.