Berat Ersarı
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Berat Ersarı has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alaettin Uçan
Department of Computer Engineering, Faculty of Engineering, Ufuk University, Incek, Ankara, Turkey
1 shared publication - Ali Seydi Keçeli
Department of Computer Engineering, Hacettepe University, Ankara, Turkey
1 shared publication - Aydin Kaya
Hacettepe University
1 shared publication - Emine Esra Karaca
Department of Ophthalmology, University of Health Sciences, Ankara Bilkent City Hospital, Ankara, Türkiye
1 shared publication - Feyza Dicle Işık
Department of Ophthalmology, Ankara Bilkent City Hospital, University of Health Sciences, 06800 Ankara, Turkey
1 shared publication - Muhammed Görkem Kola
Department of Computer Engineering, Hacettepe University, Ankara, Çankaya, Turkey
1 shared publication
Latest Publications
- 23 October 2025
- Published by Springer Nature in International Ophthalmology
- Vol. 45 (1) , 1-12
Denoising diffusion-based anterior segment optical coherence tomography (AS-OCT) image generation
Purpose This study aims to address the scarcity of annotated Anterior Segment Optical Coherence Tomography (AS-OCT) datasets in ophthalmology by using Denoising Diffusion Generative Adversarial Networks (DD-GANs) to generate synthetic AS-OCT images to produce predictive models. The goal is to produce high-quality, diverse, and realistic data supporting the training of predictive models without data imbalance issues. Methods AS-OCT images obtained from a tertiary referral hospital were used to train two DD-GAN models—one for healthy images and another for unhealthy AS-OCT images. The generated synthetic datasets were evaluated using Fréchet Inception Distance (FID) and Inception Scores to assess image quality. To further validate the synthetic data, two ResNet-50 models were trained separately on the real and synthetic datasets and evaluated on each other’s test sets to measure performance comparability. Results Two synthetic datasets were created: a smaller set with 15.7 k images (6.8 k healthy, 8.9 k unhealthy) and a larger set with 100 k images (50 k each). The FID scores were 0.17 for healthy images and 0.23 for unhealthy ones, indicating high-quality synthesis. Inception Scores were 1.46 for healthy data and 1.55 for unhealthy data. ResNet-50 models trained on synthetic data achieved results comparable to models trained on real data. Conclusion DD-GANs effectively generate realistic AS-OCT images, producing high-quality, balanced datasets that can address data scarcity and imbalance in ophthalmology. These synthetic datasets can enhance machine learning model development, advancing medical image analysis. Synthetic medical image generation provides significant advantages in protecting personal data privacy. By using artificially generated data instead of real data, patients’ identities and confidentiality are safeguarded.
- 23 October 2025
- Published by Springer Nature in International Ophthalmology
- Vol. 45 (1) , 1-12
Denoising diffusion-based anterior segment optical coherence tomography (AS-OCT) image generation
Purpose This study aims to address the scarcity of annotated Anterior Segment Optical Coherence Tomography (AS-OCT) datasets in ophthalmology by using Denoising Diffusion Generative Adversarial Networks (DD-GANs) to generate synthetic AS-OCT images to produce predictive models. The goal is to produce high-quality, diverse, and realistic data supporting the training of predictive models without data imbalance issues. Methods AS-OCT images obtained from a tertiary referral hospital were used to train two DD-GAN models—one for healthy images and another for unhealthy AS-OCT images. The generated synthetic datasets were evaluated using Fréchet Inception Distance (FID) and Inception Scores to assess image quality. To further validate the synthetic data, two ResNet-50 models were trained separately on the real and synthetic datasets and evaluated on each other’s test sets to measure performance comparability. Results Two synthetic datasets were created: a smaller set with 15.7 k images (6.8 k healthy, 8.9 k unhealthy) and a larger set with 100 k images (50 k each). The FID scores were 0.17 for healthy images and 0.23 for unhealthy ones, indicating high-quality synthesis. Inception Scores were 1.46 for healthy data and 1.55 for unhealthy data. ResNet-50 models trained on synthetic data achieved results comparable to models trained on real data. Conclusion DD-GANs effectively generate realistic AS-OCT images, producing high-quality, balanced datasets that can address data scarcity and imbalance in ophthalmology. These synthetic datasets can enhance machine learning model development, advancing medical image analysis. Synthetic medical image generation provides significant advantages in protecting personal data privacy. By using artificially generated data instead of real data, patients’ identities and confidentiality are safeguarded.