Dz.G. Uzunyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dz.G. Uzunyan has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- A. A. Zheltonozhko
S. Fyodorov Eye Microsurgery Federal State Institution, Moscow , Russian Federation
1 shared publication - Alyona A. Petukhova
S. Fyodorov Eye Microsurgery Federal State Institution
1 shared publication - Anatoly N. Bessarabov
Intersectoral Scientific and Technical Complex “Eye Microsurgery” named after Academician S.N. Fedorov
1 shared publication - D. O. Shkvorchenko
S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, Russian Federation
1 shared publication - Dmitriy S. Ostrovskiy
S. Fyodorov Eye Microsurgery Federal State Institution, Moscow , Russian Federation
1 shared publication - Dmitry Anatolievich Buryakov
S. Fyodorov Eye Microsurgery Federal State Institution, Moscow , Russian Federation
1 shared publication
Latest Publications
- 3 July 2026
- Published by Mediprint in Fyodorov journal of ophthalmic surgery
- No. 2
Fundamental and clinical aspects of turkey corneal xenotransplantation
Relevance. This study presents the main anatomical and refractive characteristics of the turkey cornea as a potential xenograft for keratoplasty. Currently, more than 12 million people are on the waiting list for keratoplasty due to a shortage of cadaveric donor corneas. Recent scientific advances demonstrate the feasibility of developing a xenograft to address this significant deficit. Purpose. To evaluate in a series of ex vivo experiments, the main anatomical, topographic, morphological and refractive characteristics of the turkey cornea (Latin: Meleagris gallopavo) as a potential xenomaterial for keratoplasty. Material and methods. Enucleated turkey eyeballs (n=28) and corneoscleral discs (n=28) were used. The research protocol included: optical coherence tomography (OCT), ultrasound biomicroscopy (UBM), measurement of the axial length, corneal diameter, and anterior chamber depth, assessment of endothelial cell density (ECD), autorefractometry, histological examination, and scanning electron microscopy (SEM). Results. The studies established that the axial length of the turkey eye is 19.2±1.07 mm, corneal thickness is 510±26.5 μm, corneal diameter is 10.2±0.2 mm, and anterior chamber depth is 3.6±0.8 mm. The endothelial cell density was 3749±388 cells/mm², and the corneal refractive power was 55.4±2.63 D. The presence of Bowman’s membrane and densely packed collagen fibers was verified. Conclusion. The main anatomical, topographic, and refractive characteristics of turkey corneas — specifically thickness, diameter, refractive power, and histological structure — position the turkey cornea as a promising alternative to scarce human donor material. This warrants further investigation into its application as a xenograft in reconstructive corneal surgery. Keywords: cornea, keratoplasty, xenotransplantation, turkey, xenograft
- 3 July 2026
- Published by Mediprint in Fyodorov journal of ophthalmic surgery
- No. 2
Fundamental and clinical aspects of turkey corneal xenotransplantation
Relevance. This study presents the main anatomical and refractive characteristics of the turkey cornea as a potential xenograft for keratoplasty. Currently, more than 12 million people are on the waiting list for keratoplasty due to a shortage of cadaveric donor corneas. Recent scientific advances demonstrate the feasibility of developing a xenograft to address this significant deficit. Purpose. To evaluate in a series of ex vivo experiments, the main anatomical, topographic, morphological and refractive characteristics of the turkey cornea (Latin: Meleagris gallopavo) as a potential xenomaterial for keratoplasty. Material and methods. Enucleated turkey eyeballs (n=28) and corneoscleral discs (n=28) were used. The research protocol included: optical coherence tomography (OCT), ultrasound biomicroscopy (UBM), measurement of the axial length, corneal diameter, and anterior chamber depth, assessment of endothelial cell density (ECD), autorefractometry, histological examination, and scanning electron microscopy (SEM). Results. The studies established that the axial length of the turkey eye is 19.2±1.07 mm, corneal thickness is 510±26.5 μm, corneal diameter is 10.2±0.2 mm, and anterior chamber depth is 3.6±0.8 mm. The endothelial cell density was 3749±388 cells/mm², and the corneal refractive power was 55.4±2.63 D. The presence of Bowman’s membrane and densely packed collagen fibers was verified. Conclusion. The main anatomical, topographic, and refractive characteristics of turkey corneas — specifically thickness, diameter, refractive power, and histological structure — position the turkey cornea as a promising alternative to scarce human donor material. This warrants further investigation into its application as a xenograft in reconstructive corneal surgery. Keywords: cornea, keratoplasty, xenotransplantation, turkey, xenograft
- 26 March 2026
- Published by Mediprint in Fyodorov journal of ophthalmic surgery
- No. 1
Results of the use of platelet rich plasma in the prevention of vitreous hemorrhages after vitrectomy of proliferative diabetic retinopathy
Purpose. To evaluate the effectiveness of platelet-rich plasma (PRP) in the prevention of persistent vitreous hemorrhages (PVH) in the surgery of proliferative diabetic retinopathy (PDR). Material and methods. This study included 64 patients (64 eyes) with the advanced stage of PDR, assigned for vitrectomy. All patients were divided into 2 groups: the main group (n=34) included patients who had PRP applied to the hemorrhage sites at the end of the surgical intervention for the prevention of PVH, the control group (n=30) — patients operated according to the standard procedure. Presence and severity of hemorrhage was determined by ophthalmoscopy and ultrasound B-scan. Results. Patients of both groups did not differ in clinical and demographic characteristics. All patients of the main group managed to apply the described technique. On the next day after surgery, PVH was observed in both groups. In the main group, the frequency of PVH was 20% (n=7), while in the control group — 63% (n=19), the differences between the groups are statistically significant. Conclusion. The use of PRP is a reliably effective, safe way to prevent PVH in PDR surgery. Keywords: proliferative diabetic retinopathy, postoperative vitreous hemorrhage, persistent vitreous hemorrhage, platelet-rich blood plasma
- 26 March 2026
- Published by Mediprint in Fyodorov journal of ophthalmic surgery
- No. 1
Results of the use of platelet rich plasma in the prevention of vitreous hemorrhages after vitrectomy of proliferative diabetic retinopathy
Purpose. To evaluate the effectiveness of platelet-rich plasma (PRP) in the prevention of persistent vitreous hemorrhages (PVH) in the surgery of proliferative diabetic retinopathy (PDR). Material and methods. This study included 64 patients (64 eyes) with the advanced stage of PDR, assigned for vitrectomy. All patients were divided into 2 groups: the main group (n=34) included patients who had PRP applied to the hemorrhage sites at the end of the surgical intervention for the prevention of PVH, the control group (n=30) — patients operated according to the standard procedure. Presence and severity of hemorrhage was determined by ophthalmoscopy and ultrasound B-scan. Results. Patients of both groups did not differ in clinical and demographic characteristics. All patients of the main group managed to apply the described technique. On the next day after surgery, PVH was observed in both groups. In the main group, the frequency of PVH was 20% (n=7), while in the control group — 63% (n=19), the differences between the groups are statistically significant. Conclusion. The use of PRP is a reliably effective, safe way to prevent PVH in PDR surgery. Keywords: proliferative diabetic retinopathy, postoperative vitreous hemorrhage, persistent vitreous hemorrhage, platelet-rich blood plasma
- Open Access
- 23 October 2025
- Published by Volgograd State Medical University in Journal of Volgograd State Medical University
- Vol. 22 (3) , 49-54
Determination of structural features of eyes with high degrees of ametropia by the method of mathematical modeling
Purpose: Determination of the characteristics of the hypermetropic and myopic eye based on retrospective analysis, prospective study and mathematical modeling. Material and methods: In the course of a retrospective study 2 groups were formed: group 1 – “High degree hyperopia”, anterior-posterior length (APL) of the eye less than 22 mm (n = 20543 eyes), group 2 – “High degree myopia”, APL of the eye more than 27 mm (n = 16718 eyes). The following data were obtained from the electronic database of medical records: visometry – uncorrected visual acuity (UCVA) and corrected visual acuity (CVA), autorefractometry data, tonometry, optical biometry of the eye, optical coherence tomography, optical power of the IOL, accompanying surgical interventions. During the prospective study 2 groups were formed: Group 1 – 35 eyes with axial length from 15.41 mm to 22.29 mm, Group 2 – 34 eyes with axial length from 27.13 to 33.39 mm. Conclusion: The calculations revealed differences characteristic of high-degree hyperopia and myopia. Using the results of additional diagnostic methods, models of eyes with high-degree hyperopia and myopia were constructed, taking into account anatomical features.
- 23 October 2025
- Published by Volgograd State Medical University in Journal of Volgograd State Medical University
- Vol. 22 (3) , 49-54
Open AccessDetermination of structural features of eyes with high degrees of ametropia by the method of mathematical modeling
Purpose: Determination of the characteristics of the hypermetropic and myopic eye based on retrospective analysis, prospective study and mathematical modeling. Material and methods: In the course of a retrospective study 2 groups were formed: group 1 – “High degree hyperopia”, anterior-posterior length (APL) of the eye less than 22 mm (n = 20543 eyes), group 2 – “High degree myopia”, APL of the eye more than 27 mm (n = 16718 eyes). The following data were obtained from the electronic database of medical records: visometry – uncorrected visual acuity (UCVA) and corrected visual acuity (CVA), autorefractometry data, tonometry, optical biometry of the eye, optical coherence tomography, optical power of the IOL, accompanying surgical interventions. During the prospective study 2 groups were formed: Group 1 – 35 eyes with axial length from 15.41 mm to 22.29 mm, Group 2 – 34 eyes with axial length from 27.13 to 33.39 mm. Conclusion: The calculations revealed differences characteristic of high-degree hyperopia and myopia. Using the results of additional diagnostic methods, models of eyes with high-degree hyperopia and myopia were constructed, taking into account anatomical features.