Andrés Cruz-Conesa
Research Subjects
Andrés Cruz-Conesa has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Itziar Ruisánchez
Universitat Rovira i Virgili, Faculty of Chemistry, Department of Analytical and Organic Chemistry, Tarragona, Spain
3 shared publicationsAnna M. Pérez-Vendrell
Institute of Agrifood Research and Technology, Animal Nutrition. Mas Bové, Constantí, Spain
2 shared publications- Elisabet Rosell-Vives
Pharmaceutical Innovation, Reig Jofre Laboratories, 08970 Barcelona, Spain
2 shared publications - Iria Naveira-Souto
Department of Biochemistry and Physiology, School of Pharmacy and Food Sciences, University of Barcelona, 08028 Barcelona, Spain
2 shared publications - Joan Ferré
Chemometrics, Qualimetrics and Nanosensors Group, Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Campus Sescelades, 43007 Tarragona, Spain
2 shared publications - Roger Fabrega Alsina
Reig Jofre Laboratories, 08970 Barcelona, Spain
2 shared publications
Latest Publications
- Open Access
Process Simulation of a Microfluidic Micromixer for Pharmaceutical Production of DNA-Lipid Nanoparticles
Background/Objectives: The question addressed in the current work is to develop a simulation of a pharmaceutical process (DNA encapsulation within lipid nanoparticles using a microfluidic micromixer) which will be of utility to the end users (laboratory-scale formulation development). The simulation and the microfluidic approach also address sustainability issues, such as reducing the environmental impact of the process itself, and reducing the need for physical testing. The paper details the implementation and validation, taking into account key performance indicators and control parameters. Methods: The main method applied for simulation development is a novel multi-agent approach to incorporate stochastic probabilistic behavior, combined with theoretical definitions from the process experts and relevant literature, and data/results from laboratory-scale experiments with different parameter configurations. Results: The simulation was implemented as a representation of the real physical process, reproducing the relationships between process parameters (flow rates) and experimental key performance indicators (capsule diameter, poly dispersion index, encapsulation efficiency). The simulation results demonstrated a general agreement with the empirical results and provided useful predictive insights for the laboratory experiments. Conclusions: The simulation has potential as a support tool for laboratory experiments to reduce physical testing and indicate the most promising configurations on which to focus, with potential savings in time, resources and other costs.
Open AccessProcess Simulation of a Microfluidic Micromixer for Pharmaceutical Production of DNA-Lipid Nanoparticles
Background/Objectives: The question addressed in the current work is to develop a simulation of a pharmaceutical process (DNA encapsulation within lipid nanoparticles using a microfluidic micromixer) which will be of utility to the end users (laboratory-scale formulation development). The simulation and the microfluidic approach also address sustainability issues, such as reducing the environmental impact of the process itself, and reducing the need for physical testing. The paper details the implementation and validation, taking into account key performance indicators and control parameters. Methods: The main method applied for simulation development is a novel multi-agent approach to incorporate stochastic probabilistic behavior, combined with theoretical definitions from the process experts and relevant literature, and data/results from laboratory-scale experiments with different parameter configurations. Results: The simulation was implemented as a representation of the real physical process, reproducing the relationships between process parameters (flow rates) and experimental key performance indicators (capsule diameter, poly dispersion index, encapsulation efficiency). The simulation results demonstrated a general agreement with the empirical results and provided useful predictive insights for the laboratory experiments. Conclusions: The simulation has potential as a support tool for laboratory experiments to reduce physical testing and indicate the most promising configurations on which to focus, with potential savings in time, resources and other costs.
- Open Access
- 13 January 2026
- Published by MDPI AG in Pharmaceutics
- Vol. 18 (1) , 105
Comparative Analysis of Sonication, Microfluidics, and High-Turbulence Microreactors for the Fabrication and Scaling-Up of Diclofenac-Loaded Liposomes
Background: Liposomes are attractive topical carriers, yet translating laboratory fabrication to scalable, well-controlled processes remains challenging. Objectives: We compared three manufacturing methods for diclofenac-loaded liposomes: probe sonication, microfluidic mixing, and a high-turbulence microreactor, under a Quality-by-Design framework. Methods: Differential scanning calorimetry (DSC) was used to define a processing-relevant liquid-crystalline temperature window for the lipid excipients. For sonication scale-up, a Plackett-Burman screening design identified key process factors and supported an energy-density (W·s·L−1) control approach. For microfluidics, the effects of flow-rate ratio (FRR) and total flow rate (TFR) were mapped and optimized using a desirability function. Microreactor trials were performed at elevated throughput. Residual ethanol during post-processing was monitored at-line by Raman spectroscopy calibrated against gas chromatography (GC). Particle size and dispersity were measured by DLS and morphology assessed by cryo-TEM. Results: DSC supported a 70–85 °C processing window. Sonication scale-up using an energy-density target (~11,000 W·s·L−1) reproduced lab-scale quality at 8 L (Z-average ~87–92 nm; PDI 0.16–0.23; %EE 86–94%). Microfluidics optimization selected FRR 3:1/TFR 4 mL·min−1, yielding ~64 nm liposomes with PDI ~0.13 and %EE ~93%. The microreactor achieved ~50 nm liposomes with %EE ~95% at 50 mL·min−1. Cryo-TEM corroborated size trends and showed no evident aggregates. Conclusions: All three routes met topical CQAs (~50–100 nm; PDI ≤ 0.30; high %EE). Method selection should be guided by target size/dispersity and operational constraints: sonication enables energy-based scale-up, microfluidics offers precise size control, and microreactors provide higher throughput.
- 13 January 2026
- Published by MDPI AG in Pharmaceutics
- Vol. 18 (1) , 105
Open AccessComparative Analysis of Sonication, Microfluidics, and High-Turbulence Microreactors for the Fabrication and Scaling-Up of Diclofenac-Loaded Liposomes
Background: Liposomes are attractive topical carriers, yet translating laboratory fabrication to scalable, well-controlled processes remains challenging. Objectives: We compared three manufacturing methods for diclofenac-loaded liposomes: probe sonication, microfluidic mixing, and a high-turbulence microreactor, under a Quality-by-Design framework. Methods: Differential scanning calorimetry (DSC) was used to define a processing-relevant liquid-crystalline temperature window for the lipid excipients. For sonication scale-up, a Plackett-Burman screening design identified key process factors and supported an energy-density (W·s·L−1) control approach. For microfluidics, the effects of flow-rate ratio (FRR) and total flow rate (TFR) were mapped and optimized using a desirability function. Microreactor trials were performed at elevated throughput. Residual ethanol during post-processing was monitored at-line by Raman spectroscopy calibrated against gas chromatography (GC). Particle size and dispersity were measured by DLS and morphology assessed by cryo-TEM. Results: DSC supported a 70–85 °C processing window. Sonication scale-up using an energy-density target (~11,000 W·s·L−1) reproduced lab-scale quality at 8 L (Z-average ~87–92 nm; PDI 0.16–0.23; %EE 86–94%). Microfluidics optimization selected FRR 3:1/TFR 4 mL·min−1, yielding ~64 nm liposomes with PDI ~0.13 and %EE ~93%. The microreactor achieved ~50 nm liposomes with %EE ~95% at 50 mL·min−1. Cryo-TEM corroborated size trends and showed no evident aggregates. Conclusions: All three routes met topical CQAs (~50–100 nm; PDI ≤ 0.30; high %EE). Method selection should be guided by target size/dispersity and operational constraints: sonication enables energy-based scale-up, microfluidics offers precise size control, and microreactors provide higher throughput.
- Open Access
- 5 June 2025
- Published by Elsevier in Poultry Science
- Vol. 104 (9) , 105394
Determination of carbohydrate and lignin content in feedstuffs for monogastric animals using near-infrared spectroscopy
- 5 June 2025
- Published by Elsevier in Poultry Science
- Vol. 104 (9) , 105394
Open AccessDetermination of carbohydrate and lignin content in feedstuffs for monogastric animals using near-infrared spectroscopy
- Open Access
- 30 December 2022
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 234
Selection of reference samples for updating multivariate calibration models used in the analysis of pig faeces
- 30 December 2022
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 234
Open AccessSelection of reference samples for updating multivariate calibration models used in the analysis of pig faeces
- Open Access
- 1 January 2022
- Published by Elsevier in Animal Feed Science and Technology
- Vol. 283
Use of visible-near infrared spectroscopy to predict nutrient composition of poultry excreta
- 1 January 2022
- Published by Elsevier in Animal Feed Science and Technology
- Vol. 283
Open AccessUse of visible-near infrared spectroscopy to predict nutrient composition of poultry excreta
- Open Access
- 1 June 2021
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 180
Multielemental analysis of Antarctic soils using calibration free laser-induced breakdown spectroscopy
- 1 June 2021
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 180
Open AccessMultielemental analysis of Antarctic soils using calibration free laser-induced breakdown spectroscopy