FPFani Paderi

Fani Paderi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fani Paderi has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Inertial Sensor Reliability and Validity Across a Five-Level Surface Instability Gradation During Single-Leg Standing

    by Fani Paderi, Analina Emmanouil, Konstantinos Boudolos, Elissavet Rousanoglou

    Wearable inertial sensors offer a portable alternative to laboratory-grade force plates for postural stability assessment; however, their validity across progressively challenging balance tasks remains under-explored. This study evaluated the reliability and concurrent validity of inertially sensed metrics compared with force-plate-derived postural sway metrics across a five-level spectrum of unstable surfaces (Floor, Foam Pad, Rotating Disc, Air Disc, Bosu). Twenty-five healthy young women (22.1 ± 3.6 years, 1.64 ± 0.04 m, 58.44 ± 8.21 kg) performed five trials of single-leg standing (40 s each) on each surface. Postural sway was computed from antero-posterior (AP) and medio-lateral (ML) center of pressure (CoP) recordings using a force plate (Kistler, 9286 AA, Winterthur, Switzerland, sampling at 500 Hz) in synchronization with a lateral shank-mounted inertial sensor (Bionomadix BN-ACCL3, Biopac Systems, Inc., Santa Barbara, CA, USA, sampling at 100 Hz). In addition to reliability, a two-tiered analysis evaluated global concordance (unstandardized slopes) and method agreement (standardized z-scores). Intraclass correlation coefficients (ICCs) for the inertial sensor were excellent (range: 0.95–0.96), surpassing the force plate (range: 0.85–0.92) as trials accumulated. Analysis revealed moderate-to-good global concordance in the AP direction (r = 0.60, p = 0.001) and good-to-excellent in the ML one (r = 0.85, p < 0.001), validating the progressive intensifying effect of the surface graduation. Individual ranking agreement—evaluated via standardized z-scores—was also significant in both the AP (r = 0.61, p < 0.001) and the ML (r = 0.85, p < 0.001) directions, indicating a convergence into how the two modalities rank individual performance. Bland–Altman plots confirmed high absolute agreement between standardized scores, though a predictable proportional bias was observed in raw units, where the inertial sensor’s underestimation of sway magnitude increased linearly with task difficulty. The five-level postural challenge graduation is a highly reliable framework for balance assessment. While the shank-mounted sensor exhibits proportional underestimation of sway magnitude compared to the CoP at extreme intensities, its high internal stability and sensitivity to task difficulty make it a valid and robust tool for longitudinal clinical monitoring.


  • Open Access

    The Task Dependency of Spontaneous Rhythmic Performance in Movements Beyond Established Biomechanical Models: An Inertial Sensor-Based Study

    by Analina Emmanouil, Fani Paderi, Konstantinos Boudolos, Elissavet Rousanoglou

    Spontaneous rhythmic performance is a fundamental feature of human movement, well established in biomechanical models (EBMs) but less understood in complex physical fitness exercises (PFEs). This study examined the task dependency of spontaneous rhythmic performance across three EBMs (walking, hopping, finger tapping) and seven PFEs (hip abduction, back extension, sit-up, push-up, shoulder abduction, squat, lunge). A total of 15 men and 15 women performed each task at a self-selected pace while wearing inertial sensors. Measures included spontaneous motor tempo (SMT), temporal structure metrics, and their within- and between-trial individual variability (%CV) (ANOVA, SPSS 28.0, p ≤ 0.05). SMT was task-dependent, with EMB tasks being near ~2 Hz (walking: 1.82 ± 0.10 Hz; hopping: 2.08 ± 0.22 Hz; finger tapping: 1.89 ± 0.43 Hz) and PFEs being slower (0.36–0.68 Hz). Temporal structure mirrored these differences with shorter cycle and phase durations in EBM than PFE tasks, with relative phase durations consistently at about a 1:1 ratio. Τhe overall low %CV indicated stable performance (within-trial: 1.4–7.5%; between-trial: 0.5–7.8%). The results highlight the task dependency of SMT and temporal structure, as well as the robustness of an overarching internal timing framework supporting rhythmic motor control across diverse movement contexts.