Qi Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qi Zheng has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Liangzhi Cao
3 shared publicationsQingming He
Xi’an Jiaotong University
3 shared publicationsXiaozhi Zhang
The First Affiliated Hospital of Xi’an Jiaotong University
3 shared publicationsBo Wang
Ningbo University
2 shared publicationsHeyu Peng
Xi’an Jiaotong University
2 shared publicationsHongchun Wu
Xi’an Jiaotong University
2 shared publications
Latest Publications
- Open Access
- 25 October 2026
- Published by Elsevier in SSRN Electronic Journal
Parametrical Study on the Convergence and Accuracy of Three-Dimensional Random Ray Transport Calculations with Consistent CMFD Acceleration
Consistent coarse-mesh finite difference (CMFD) acceleration in random ray transport eigenvalue calculations constructs and solves low-order equations from transport tallies, then uses the solution to correct the transport flux and update the fission source. We examine how the tally-window length, relaxation factor, number of rays per cycle, active length per ray, and axial CMFD mesh resolution affect fission-source convergence, eigenvalue deviation, and pin-power error in C5G7-3D and three C5G7-3D Extension problems. For the Rodded-A problem with a 20-cycle tally window, increasing the relaxation factor from 0.3 to 0.7 raises the mean integrated pin-power RMS error across five random-number seeds from 0.816% to 11.636%. All 13 attempted CMFD updates are accepted in every calculation at both relaxation factors. At 0.7, however, the mean k_eff over active cycles 1–50 is 2222–2242 pcm higher than the mean over cycles 101–150 in each calculation. With the random-number seed held fixed, extending the cycle schedule at this relaxation factor from 250 inactive and 150 active cycles to 1000 and 400 reduces the integrated pin-power RMS error from 13.653% to 1.294%, but eight successive 50-cycle active-block eigenvalue means still increase monotonically by 97.5 pcm from first to last. In the Rodded-B problem, increasing either the number of rays per cycle or the active length per ray eightfold raises the mean eigenvalue across five random-number seeds by 347–357 pcm, while the mean integrated pin-power RMS error decreases by 0.057–0.060 percentage points.
- 25 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessParametrical Study on the Convergence and Accuracy of Three-Dimensional Random Ray Transport Calculations with Consistent CMFD Acceleration
Consistent coarse-mesh finite difference (CMFD) acceleration in random ray transport eigenvalue calculations constructs and solves low-order equations from transport tallies, then uses the solution to correct the transport flux and update the fission source. We examine how the tally-window length, relaxation factor, number of rays per cycle, active length per ray, and axial CMFD mesh resolution affect fission-source convergence, eigenvalue deviation, and pin-power error in C5G7-3D and three C5G7-3D Extension problems. For the Rodded-A problem with a 20-cycle tally window, increasing the relaxation factor from 0.3 to 0.7 raises the mean integrated pin-power RMS error across five random-number seeds from 0.816% to 11.636%. All 13 attempted CMFD updates are accepted in every calculation at both relaxation factors. At 0.7, however, the mean k_eff over active cycles 1–50 is 2222–2242 pcm higher than the mean over cycles 101–150 in each calculation. With the random-number seed held fixed, extending the cycle schedule at this relaxation factor from 250 inactive and 150 active cycles to 1000 and 400 reduces the integrated pin-power RMS error from 13.653% to 1.294%, but eight successive 50-cycle active-block eigenvalue means still increase monotonically by 97.5 pcm from first to last. In the Rodded-B problem, increasing either the number of rays per cycle or the active length per ray eightfold raises the mean eigenvalue across five random-number seeds by 347–357 pcm, while the mean integrated pin-power RMS error decreases by 0.057–0.060 percentage points.
- 30 July 2026
- Published by Taylor & Francis in Nuclear Science and Engineering
- p. 1-15
Direct and IKS Monte Carlo Methods in Flight-Based and Collision-Based Frameworks for Frequency-Domain Neutron Noise Calculation
I. Neutron noise technology serves as a cornerstone for the online safety monitoring and fault diagnosis of nuclear reactors [1], especially for Generation III and Generation IV reactors where real...
- 30 July 2026
- Published by Taylor & Francis in Nuclear Science and Engineering
- p. 1-15
Direct and IKS Monte Carlo Methods in Flight-Based and Collision-Based Frameworks for Frequency-Domain Neutron Noise Calculation
I. Neutron noise technology serves as a cornerstone for the online safety monitoring and fault diagnosis of nuclear reactors [1], especially for Generation III and Generation IV reactors where real...
- Open Access
- 11 March 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (7)
Research on hybrid methods for variance reduction in Monte Carlo dose calculation of BNCT
- 11 March 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (7)
Open AccessResearch on hybrid methods for variance reduction in Monte Carlo dose calculation of BNCT
- 10 December 2025
- Published by Taylor & Francis in Nuclear Technology
- p. 1-15
BNCT Multifield Treatment Plan Optimization Based on the Barrier Algorithm
- 10 December 2025
- Published by Taylor & Francis in Nuclear Technology
- p. 1-15
BNCT Multifield Treatment Plan Optimization Based on the Barrier Algorithm
- Open Access
- 22 October 2025
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 66 (6) , 627-637
Research on the dose calculation of BNCT based on the time-varying boron concentration in pharmacokinetics
Boron Neutron Capture Therapy (BNCT) is a targeted radiotherapy that utilizes the nuclear reaction of 10B with thermal neutrons to destroy tumor cells while sparing healthy tissue. Its effectiveness relies on accurately modeling boron distribution. Current treatment planning systems use a fixed tumor-to-normal tissue (T/N) boron ratio, ignoring pharmacokinetics. This study improves BNCT dose calculations by integrating time-dependent boron concentrations from pharmacokinetic simulations. Firstly, this research improved the traditional two-compartment pharmacokinetic model to a three-compartment model to better represent boron distribution, accounting for different tumor locations. Two patient cases were simulated, and the comparisons were performed between the dose distributions obtained by the fixed T/N ratio method and the ones obtained by our pharmacokinetic-based approach. Results showed significant discrepancies between the two methods, with the maximum dose deviation in the tumor region reaching 11.386%. The pharmacokinetic-based method provided more accurate and individualized dose calculations. Secondly, the multi-objective optimization using the Basin Hopping algorithm was employed to determine the optimal irradiation time periods. This approach enhanced treatment efficacy by increasing the average dose and maximum dose in the gross tumor volume by ~4% within the same irradiation period, while minimizing damage to normal tissues. The optimized irradiation schedules resulted in improved dose delivery to the tumor while maintaining safe levels for normal tissues. Our findings highlight the importance of integrating pharmacokinetic data into BNCT treatment planning to improve dose accuracy and treatment outcomes.
- 22 October 2025
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 66 (6) , 627-637
Open AccessResearch on the dose calculation of BNCT based on the time-varying boron concentration in pharmacokinetics
Boron Neutron Capture Therapy (BNCT) is a targeted radiotherapy that utilizes the nuclear reaction of 10B with thermal neutrons to destroy tumor cells while sparing healthy tissue. Its effectiveness relies on accurately modeling boron distribution. Current treatment planning systems use a fixed tumor-to-normal tissue (T/N) boron ratio, ignoring pharmacokinetics. This study improves BNCT dose calculations by integrating time-dependent boron concentrations from pharmacokinetic simulations. Firstly, this research improved the traditional two-compartment pharmacokinetic model to a three-compartment model to better represent boron distribution, accounting for different tumor locations. Two patient cases were simulated, and the comparisons were performed between the dose distributions obtained by the fixed T/N ratio method and the ones obtained by our pharmacokinetic-based approach. Results showed significant discrepancies between the two methods, with the maximum dose deviation in the tumor region reaching 11.386%. The pharmacokinetic-based method provided more accurate and individualized dose calculations. Secondly, the multi-objective optimization using the Basin Hopping algorithm was employed to determine the optimal irradiation time periods. This approach enhanced treatment efficacy by increasing the average dose and maximum dose in the gross tumor volume by ~4% within the same irradiation period, while minimizing damage to normal tissues. The optimized irradiation schedules resulted in improved dose delivery to the tumor while maintaining safe levels for normal tissues. Our findings highlight the importance of integrating pharmacokinetic data into BNCT treatment planning to improve dose accuracy and treatment outcomes.
- 16 September 2025
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (4) , 417-425
Acceleration study of a BNCT dose calculation engine based on NECP-MCX
- 16 September 2025
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (4) , 417-425
Acceleration study of a BNCT dose calculation engine based on NECP-MCX