Julian Raub
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Julian Raub has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Mahmut Selman Sakar
Institute of Mechanical Engineering École Polytechnique Fédérale de Lausanne Lausanne Switzerland
2 shared publications Ece Özelçi
Institute of Mechanical Engineering, École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
1 shared publicationLoic Von Deschwanden
Institute of Mechanical Engineering, Ecole Polytechnique Fdrale de Lausanne (EPFL), Lausanne, Switzerland
1 shared publicationLucio Pancaldi
Institute of Mechanical Engineering, Ecole Polytechnique Fdrale de Lausanne (EPFL), Lausanne, Switzerland
1 shared publication- Lucio Pancaldi
Institute of Mechanical Engineering, École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
1 shared publication - Mehdi Ali Gadiri
Institute of Mechanical Engineering, École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
1 shared publication
Latest Publications
- Open Access
- 26 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (2) , 2114-2121
Design and Actuation of a Multipole Ring Magnet for Navigating Endovascular Magnetic Instruments
This letter presents the design and analysis of a compact magnetic field generator for robotic navigation of magnetic endovascular instruments in clinical settings. The system features eight symmetrically arranged permanent magnets in a ring configuration, maximizing magnetic field uniformity and aperture size for X-ray transmission while minimizing spatial footprint and magnet motion for uninterrupted fluoroscopy imaging. The rationale behind the design of the system is explained through analytical considerations of magnetic field distribution. In vitro demonstrations inside perfused biomimetic phantoms confirm the system's capability for 3D steering of flow-driven magnetic microcatheters, opening a path for pre-clinical testing.
- 26 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (2) , 2114-2121
Open AccessDesign and Actuation of a Multipole Ring Magnet for Navigating Endovascular Magnetic Instruments
This letter presents the design and analysis of a compact magnetic field generator for robotic navigation of magnetic endovascular instruments in clinical settings. The system features eight symmetrically arranged permanent magnets in a ring configuration, maximizing magnetic field uniformity and aperture size for X-ray transmission while minimizing spatial footprint and magnet motion for uninterrupted fluoroscopy imaging. The rationale behind the design of the system is explained through analytical considerations of magnetic field distribution. In vitro demonstrations inside perfused biomimetic phantoms confirm the system's capability for 3D steering of flow-driven magnetic microcatheters, opening a path for pre-clinical testing.
- 22 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (107) , eadu4003
Flow-driven magnetic microcatheter for superselective arterial embolization
Minimally invasive interventions performed inside brain vessels with the synergistic use of microcatheters pushed over guidewires have revolutionized the way aneurysms, strokes, arteriovenous malformations, brain tumors, and other cerebrovascular conditions are being treated. However, a substantial portion of the brain vasculature remains inaccessible because the conventional catheterization technique based on transmitting forces from the proximal to the distal end of the instruments imposes stringent constraints on their diameter and stiffness. Here, we overcame this mechanical barrier by microengineering ultraminiaturized magnetic microcatheters in the form of an inflatable flat tube, making them ultraflexible and capable of harnessing the kinetic energy of blood flow for endovascular navigation. We introduce a compact and versatile magnetic steering platform that is compatible with conventional biplane fluoroscope imaging and demonstrate safe and effortless navigation and tracking of hard-to-reach, distal, tortuous arteries that are as small as 180 micrometers in diameter with a curvature radius as small as 0.69 millimeters. Furthermore, we demonstrate the superselective infusion of contrast and embolic liquid agents, all in a porcine model. These results pave the way to reach, diagnose, and treat currently inaccessible distal arteries that may be at risk of bleeding or feeding a tumor. Our endovascular technology can also be used to selectively target tissues for drug or gene delivery from within the arteries, not only in the central and peripheral nervous systems but also in almost any other organ system, with improved accuracy, speed, and safety.
- 22 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (107) , eadu4003
Flow-driven magnetic microcatheter for superselective arterial embolization
Minimally invasive interventions performed inside brain vessels with the synergistic use of microcatheters pushed over guidewires have revolutionized the way aneurysms, strokes, arteriovenous malformations, brain tumors, and other cerebrovascular conditions are being treated. However, a substantial portion of the brain vasculature remains inaccessible because the conventional catheterization technique based on transmitting forces from the proximal to the distal end of the instruments imposes stringent constraints on their diameter and stiffness. Here, we overcame this mechanical barrier by microengineering ultraminiaturized magnetic microcatheters in the form of an inflatable flat tube, making them ultraflexible and capable of harnessing the kinetic energy of blood flow for endovascular navigation. We introduce a compact and versatile magnetic steering platform that is compatible with conventional biplane fluoroscope imaging and demonstrate safe and effortless navigation and tracking of hard-to-reach, distal, tortuous arteries that are as small as 180 micrometers in diameter with a curvature radius as small as 0.69 millimeters. Furthermore, we demonstrate the superselective infusion of contrast and embolic liquid agents, all in a porcine model. These results pave the way to reach, diagnose, and treat currently inaccessible distal arteries that may be at risk of bleeding or feeding a tumor. Our endovascular technology can also be used to selectively target tissues for drug or gene delivery from within the arteries, not only in the central and peripheral nervous systems but also in almost any other organ system, with improved accuracy, speed, and safety.