SOSeunghun Oh

Seunghun Oh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Seunghun Oh has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Chulhong Kim

    Pohang University of Science and Technology (POSTECH)

    2 shared publications
  • Hyunsu Jeong

    Graduate School of Artificial Intelligence, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea

    2 shared publications
  • Bum Joon Kim

    Department of Neurology, Asan Medical Center, University of Ulsan, College of Medicine, Seoul, Korea

    1 shared publication
  • Dong Young Jeong

    School of Convergence Science and Technology, Pohang University of Science and Technology (POSTECH), Pohang, Republic of Korea

    1 shared publication
  • Jinge Yang

    Departments of Medical Engineering California Institute of Technology California 91125 USA

    1 shared publication
  • Jiwoong Kim

    Graduate School of Artificial Intelligence Departments of Electrical Engineering Convergence IT Engineering Mechanical Engineering Medical Science and Engineering and Medical Device Innovation Center Pohang University of Science and Technology (POSTECH) Pohang 37673 Republic of Korea

    1 shared publication

Latest Publications

  • Mixture-of-Skip-Connection Deep Learning Model to Classify Stroke Severity from Diffusion Weighted Imaging Based on NIHSS

    by Seunghun Oh, Hyunsu Jeong, Yoonjae Cho, Kiduk Kim, Chulhong Kim, Dong Young Jeong, Bum Joon Kim

    The National Institutes of Health Stroke Scale (NIHSS) is a quantitative tool, grading neurological deficits and guiding acute stroke management; however, bedside scoring is labor-intensive, time-consuming, and subject to interrater variability. This study proposes the TRansformer And Coordinate-aTtention NETwork (TRACT-NET), which includes a mixture-residual block, to predict stroke severity based on NIHSS score and diffusion-weighted imaging (DWI) scans. A 3D coordinate-attentive module and a 3D efficient self-attentive module were embedded into the mixture block for skip connection, enhancing feature representation by capturing axis awareness and long-range dependency. In the bottleneck stage, Mamba, a selective state-space model, was used to refine feature maps capturing relevant information from long sequences. TRACT-NET was evaluated with three-fold cross-validation of DWI and NIHSS data from 273 patients at Asan Medical Center (AMC) and externally validated on Stroke Outcome Optimization Project (SOOP) dataset, which includes 1106 patients. Patients were divided into binary groups: minor and non-minor strokes. TRACT-NET outperformed other classification models in predicting binary stroke severity. On the AMC dataset, it achieved 0.81 sensitivity, 0.9645 specificity, 0.8188 positive predictive value (PPV), 0.8054 negative predictive value (NPV), 0.7946 F1-score, 0.8137 accuracy, and 0.8137 area under the curve (AUC). On the SOOP dataset, the model achieved 0.6896 sensitivity, 0.7881 specificity, 0.7054 PPV, 0.6360 NPV, 0.6875 F1-score, 0.6896 accuracy, and 0.7094 AUC. Receiver operating characteristic curves demonstrated robust discriminative performance, whereas gradient-weighted class activation mapping results highlighted that TRACT-NET focused on clinically relevant DWI regions. These findings suggest TRACT-NET could assist stroke severity assessment in emergency situations, facilitating effective treatment decisions.

  • Open Access

    A Hybrid Diffusion Model Enhances Multiparametric 3D Photoacoustic Computed Tomography

    by Hyunsu Jeong, Seunghun Oh, Seongwook Choi, Jiwoong Kim, Jinge Yang, Chulhong Kim

    Photoacoustic computed tomography (PACT) reveals biological structures, pharmacokinetics, and physiological functions. Although a premium PACT system with many ultrasound (US) transducers delivers high‐quality volumetric imaging, it suffers from high system costs and slow temporal resolution. Here, using a limited number of US elements, a hybrid diffusion model (HD‐PACT) is demonstrated that enhances dynamic multiparametric (structural, functional, and contrast‐enhanced) 3D PACT. Using just 256 out of the 1024 elements in a premier hemispherical US array for PACT, HD‐PACT improves structural images acquired in different planes, organisms, and wavelengths. In functional imaging, HD‐PACT enables 256‐element PACT to observe hypoxia, pharmacokinetics, and angiogenesis during tumor progression. Lastly, HD‐PACT is transferable to low‐end PACT (only 128 US elements), where it dynamically captures contrast‐free/enhanced organs, oxygen‐perturbed brains, and cardiac dynamics with high spatiotemporal resolution in live animals. It is believed that HD‐PACT will be valuable in oncology, cardiology, pharmacology, and endocrinology.