Zhibo Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhibo Xiao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Xiali Gao
College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou 310027, China
3 shared publications - Xuanhao Wang
Zhejiang Lab
3 shared publications - Fan Meng
College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou 310027, China
2 shared publications - Junhui Shi
Zhejiang Lab
2 shared publications - Xiangdi Li
Zhejiang Lab, Hangzhou 311100, China
2 shared publications - Yang Xiao
Zhejiang Lab, Hangzhou 311100, China
2 shared publications
Latest Publications
- Open Access
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaeb7362
Three-dimensional aperture-driven photoacoustic tomography (3D-ADPAT)
As a powerful modality for biomedical research, photoacoustic computed tomography (PACT) offers the combination of optical specificity and acoustic penetration for in vivo visualization. However, its performance is limited by a trade-off between ultrasound detection aperture and sensitivity, compromising image contrast, resolution, and penetration depth. Here, we introduce three-dimensional aperture-driven photoacoustic tomography (3D-ADPAT) to overcome these limitations, synergistically combining a high–numerical-aperture focused ultrasonic transducer (HNA-FUT) with a phase-inverted focusing-equivalent reconstruction (PIFER) algorithm. This approach yields ~2.21-fold enhancement in spatial resolution and ~10-fold increase in contrast-to-noise ratio. 3D-ADPAT’s performance was validated through comprehensive simulations and phantom studies and further confirmed by in vivo whole-body imaging that resolved deep-seated anatomies and tracked small-molecule metabolic pathways. Furthermore, a barrel-shaped array–based 3D-ADPAT implementation was designed, supporting dynamic imaging within a large field of view or across variable spatiotemporal scales. In summary, 3D-ADPAT provides a powerful tool for advanced photoacoustic systems, promising to accelerate frontier biomedical research.
- 26 June 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (26) , eaeb7362
Open AccessThree-dimensional aperture-driven photoacoustic tomography (3D-ADPAT)
As a powerful modality for biomedical research, photoacoustic computed tomography (PACT) offers the combination of optical specificity and acoustic penetration for in vivo visualization. However, its performance is limited by a trade-off between ultrasound detection aperture and sensitivity, compromising image contrast, resolution, and penetration depth. Here, we introduce three-dimensional aperture-driven photoacoustic tomography (3D-ADPAT) to overcome these limitations, synergistically combining a high–numerical-aperture focused ultrasonic transducer (HNA-FUT) with a phase-inverted focusing-equivalent reconstruction (PIFER) algorithm. This approach yields ~2.21-fold enhancement in spatial resolution and ~10-fold increase in contrast-to-noise ratio. 3D-ADPAT’s performance was validated through comprehensive simulations and phantom studies and further confirmed by in vivo whole-body imaging that resolved deep-seated anatomies and tracked small-molecule metabolic pathways. Furthermore, a barrel-shaped array–based 3D-ADPAT implementation was designed, supporting dynamic imaging within a large field of view or across variable spatiotemporal scales. In summary, 3D-ADPAT provides a powerful tool for advanced photoacoustic systems, promising to accelerate frontier biomedical research.
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in BME Frontiers
- Vol. 7
Photoacoustic Tomography Tracks Vascular Remodeling and Functional Recovery in Liver Regeneration
Objective: This study aims to longitudinally monitor hepatic vascular remodeling and functional recovery during liver regeneration in mice using 3-dimensional panoramic photoacoustic computed tomography (3D-PanoPACT). Impact Statement: By enabling noninvasive, whole-organ spatiotemporal tracking within the same animal, this work establishes a novel imaging framework for staging organ regeneration and mapping vascular dynamics. Introduction: Hepatic vascular remodeling is critical for successful liver regeneration; however, existing imaging modalities lack the capacity for noninvasive, longitudinal, 3D characterization at the whole-organ scale. Methods: Male nude mice under isoflurane anesthesia underwent 70% partial hepatectomy or served as controls. A custom 3D-PanoPACT system performed continuous whole-organ imaging over 16 d. Quantitative vascular parameters, contrast clearance kinetics, and histological validation via hematoxylin and eosin and CD31 staining were assessed. Serum biochemical analyses independently evaluated hepatobiliary functional recovery. Results: 3D-PanoPACT delineated 3 temporally distinct vascular remodeling phases: proliferative (days 2 to 4), recovery (days 5 to 9), and remodeling (days 10 to 16). By day 16, regenerated livers exhibited no significant differences from normal controls in vascular volume, vessel length, mean diameter, or branching density, which was further confirmed by CD31 evaluation. While functional imaging showed a slightly delayed early peak enhancement, long-term metabolic clearance remained similar to that of normal controls. This functional recovery was independently corroborated by normal-like serum biochemical profiles at day 16. Conclusion: 3D-PanoPACT enables noninvasive, longitudinal tracking of hepatic regeneration. By delineating distinct morphological phases and complementing them with metabolic and biochemical validations, this framework effectively maps macroscopic vascular remodeling and confirms adequate functional recovery by day 16.
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in BME Frontiers
- Vol. 7
Photoacoustic Tomography Tracks Vascular Remodeling and Functional Recovery in Liver Regeneration
Objective: This study aims to longitudinally monitor hepatic vascular remodeling and functional recovery during liver regeneration in mice using 3-dimensional panoramic photoacoustic computed tomography (3D-PanoPACT). Impact Statement: By enabling noninvasive, whole-organ spatiotemporal tracking within the same animal, this work establishes a novel imaging framework for staging organ regeneration and mapping vascular dynamics. Introduction: Hepatic vascular remodeling is critical for successful liver regeneration; however, existing imaging modalities lack the capacity for noninvasive, longitudinal, 3D characterization at the whole-organ scale. Methods: Male nude mice under isoflurane anesthesia underwent 70% partial hepatectomy or served as controls. A custom 3D-PanoPACT system performed continuous whole-organ imaging over 16 d. Quantitative vascular parameters, contrast clearance kinetics, and histological validation via hematoxylin and eosin and CD31 staining were assessed. Serum biochemical analyses independently evaluated hepatobiliary functional recovery. Results: 3D-PanoPACT delineated 3 temporally distinct vascular remodeling phases: proliferative (days 2 to 4), recovery (days 5 to 9), and remodeling (days 10 to 16). By day 16, regenerated livers exhibited no significant differences from normal controls in vascular volume, vessel length, mean diameter, or branching density, which was further confirmed by CD31 evaluation. While functional imaging showed a slightly delayed early peak enhancement, long-term metabolic clearance remained similar to that of normal controls. This functional recovery was independently corroborated by normal-like serum biochemical profiles at day 16. Conclusion: 3D-PanoPACT enables noninvasive, longitudinal tracking of hepatic regeneration. By delineating distinct morphological phases and complementing them with metabolic and biochemical validations, this framework effectively maps macroscopic vascular remodeling and confirms adequate functional recovery by day 16.
- 22 October 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (5)
High‐Speed Photoacoustic Volumetric Flow Tomography(PVFT)
Flow field analysis is critical in industrial and biomedical applications. Optical‐based methods suffer from limited penetration depth, while ultrasound‐based approaches are constrained by angular dependence in detection, making them unsuitable for 3D imaging in turbid media. Photoacoustic Volumetric Flow Tomography (PVFT) employs laser‐excited photoacoustic signals from nickel‐coated polystyrene particles, thereby combining the high contrast of optical imaging with the superior penetration depth of ultrasound detection. The system utilizes a 1024‐element hemispherical sensor array for volumetric signal acquisition, eliminating scanning‐induced latency while achieving measurable flow velocities spanning from 40 to 1200 mm s −1 . Experimental validation using vortex flow phantoms demonstrated high‐speed 3D imaging capabilities in turbid media at 50 frames per second (fps), with systematic confirmation of angular independence. Arterial phantom experiments successfully resolved fine flow structures, attaining velocity vector reconstruction with 480 µm spatial resolution. At a flow velocity of 125 mm s −1 , the relative measurement error is quantified at 8%. Stenotic regions exhibited accelerated flow dynamics accompanied by vortex formation. This technique establishes a groundbreaking solution for 3D flow field characterization in turbid media, overcoming conventional optical diffusion limitations and ultrasound Doppler dimensional constraints.
- 22 October 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (5)
High‐Speed Photoacoustic Volumetric Flow Tomography(PVFT)
Flow field analysis is critical in industrial and biomedical applications. Optical‐based methods suffer from limited penetration depth, while ultrasound‐based approaches are constrained by angular dependence in detection, making them unsuitable for 3D imaging in turbid media. Photoacoustic Volumetric Flow Tomography (PVFT) employs laser‐excited photoacoustic signals from nickel‐coated polystyrene particles, thereby combining the high contrast of optical imaging with the superior penetration depth of ultrasound detection. The system utilizes a 1024‐element hemispherical sensor array for volumetric signal acquisition, eliminating scanning‐induced latency while achieving measurable flow velocities spanning from 40 to 1200 mm s −1 . Experimental validation using vortex flow phantoms demonstrated high‐speed 3D imaging capabilities in turbid media at 50 frames per second (fps), with systematic confirmation of angular independence. Arterial phantom experiments successfully resolved fine flow structures, attaining velocity vector reconstruction with 480 µm spatial resolution. At a flow velocity of 125 mm s −1 , the relative measurement error is quantified at 8%. Stenotic regions exhibited accelerated flow dynamics accompanied by vortex formation. This technique establishes a groundbreaking solution for 3D flow field characterization in turbid media, overcoming conventional optical diffusion limitations and ultrasound Doppler dimensional constraints.