DSDiego Soriano-Mena

Diego Soriano-Mena

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Diego Soriano-Mena has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SCOUT® Radar Reflector for Nonpalpable Breast Lesion Localization: Clinical Outcomes from a Single-Center Experience

    by Julieta Puente-Monserrat, Ernesto Muñoz-Sornosa, Vicente López-Flor, Marcos Adrianzén-Vargas, Dixie Huntley-Pascual, Georgy Kadzhaya-Khlystov, Diego Soriano-Mena, Elvira Buch-Villa

    Background: Preoperative localization of non-palpable breast lesions is critical for accurate resection and margin control in breast-conserving surgery. Traditional methods, such as wire or radioguided localization, have limitations in terms of logistics, patient comfort, and procedural flexibility. SCOUT® is a wireless, radar-based alternative that may improve surgical precision and workflow. This study aimed to evaluate the clinical performance of the SCOUT® in the localization of non-palpable breast and axillary lesions, including detection success, margin status, reoperation rates, and device-related events. Methods: We conducted a retrospective, single-centre observational study including 427 patients who underwent breast-conserving surgery after preoperative localization using the SCOUT® between January 2023 and May 2024 at a tertiary academic hospital. Variables included lesion type, location, neoadjuvant treatment, device detection, seed deactivation, MRI interference, margin status, and reoperation rate. Results: The mean age was 58 ± 12.7 years, with malignant pathology in 88.5% of cases. SCOUT® achieved a 100% detection rate in axillary localizations and 98.1% in breast lesions. Seed deactivation occurred in 1.2% of cases, all successfully managed intraoperatively. MRI artefacts were observed in 1.6% of patients, without diagnostic interference. Positive margins were reported in 8.3% of cases, representing an improvement compared with the institution’s historic 12% rate, with 5.9% requiring reoperation. Carcinoma in situ showed the highest rate of positive margins, at 26%. Conclusions: SCOUT® was associated with high detection rates, a low incidence of device-related events, and favourable margin outcomes, supporting its reliability for the localization of non-palpable breast lesions.

  • Open Access

    SCOUT® Radar Reflector for Nonpalpable Breast Lesion Localization: Clinical Outcomes from a Single-Center Experience

    by Julieta Puente-Monserrat, Ernesto Muñoz Sornosa, Marcos Adrianzén-Vargas, Vicente López-Flor, Dixie Huntley-Pascual, Georgy Kadzhaya-Klhystov, Diego Soriano-Mena, Elvira Buch-Villa

    Background: Preoperative localization of non-palpable breast lesions is critical for accurate resection and margin control in breast-conserving surgery. Traditional methods, such as wire or radioguided localization, have limitations in terms of logistics, patient comfort, and procedural flexibility. SCOUT® is a wireless, radar-based alternative that may improve surgical precision and workflow. Methods: We conducted a retrospective cohort study of 427 patients undergoing breast-conserving surgery after preoperative localization using the SCOUT® system between January 2023 and May 2024 at a tertiary academic hospital. Variables included lesion type, location, neoadjuvant treatment, device detection, seed deactivation, MRI interference, margin status, and reoperation rate. Results: The mean age was 58 years (SD 12.7), with malignant pathology in 88.5% of cases. SCOUT® achieved a 100% detection rate in axillary localizations and 98.1% in breast lesions. Seed deactivation occurred in 1.17% of cases, all successfully managed intraoperatively. MRI artefacts were observed in 1.59% of patients, without diagnostic interference. Positive margins were reported in 8.3% of cases, representing an improvement compared with the institution’s historical 12% rate, with 5.9% requiring reoperation. The device remained functional after neoadjuvant therapy in all applicable cases. Conclusions: SCOUT® demonstrated high detection rates, low complication incidence, and reduced positive margin rates, supporting its reliability for the localization of non-palpable breast lesions. These findings reinforce SCOUT® as an effective alternative to conventional localization techniques, with potential to optimize breast-conserving surgery and reduce reoperations.