Adel Abdou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Adel Abdou has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Abdullahi Abdulrahman Muhudin
Department of Environmental Sciences and Policy, Central European University, Quellenstraße 51, 1100 Wien, Austria
1 shared publication - Emmanuel Essah
School of Built Environment, University of Reading, Reading, UK
1 shared publication Ismail M. Budaiwi
King Fahd Univ. of Petroleum and Minerals (KFUPM), Interdisciplinary Research Center for Construction and Building Materials, KFUPM
1 shared publication- Ismail Mohammed Budaiwi1 shared publication
- Maimonah Almaqremi1 shared publication
- Mohammad S. Al-Homoud
King Fahd Univ. of Petroleum and Minerals
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1)
Assessing Indoor Environmental Quality (IEQ) Challenges in Autism Schools: Insights From Saudi Arabia′s Eastern Region
Saudi Arabia′s Vision 2030 prioritises enhancing special education services for children with special needs, including autistic pupils who are particularly sensitive to their surrounding environment. Given that autistic pupils spend significant time in schools, Indoor Environmental Quality (IEQ) is critical for their well‐being and learning outcomes yet remains underexplored. This study adopts a descriptive comparative design, using continuous monitoring and classroom activity observations to evaluate IEQ conditions in two autism schools in the Dammam region of Saudi Arabia during winter and summer. Measurements included air temperature, relative humidity, particulate matter (PM 2.5 and PM 10 ) concentrations, CO 2 levels, sound and lighting in classrooms. The IEQ parameters were measured using specific instruments installed at pupil level to accurately reflect their exposure. The findings reveal significant challenges in maintaining acceptable IEQ. PM 2.5 and PM 10 concentrations exceeded WHO guidelines, with PM 2.5 averaging 51 μ g/m 3 in School A and 30 μ g/m 3 in School B. PM 10 levels were even higher, peaking at 116 μ g/m 3 in School A and 101 μ g/m 3 in School B. These concentrations surpass those reported in mainstream schools in the same region, largely due to unique classroom activities (e.g., drawing, light physical activity) and cleaning practices (e.g., burning incense and use of sprays) prevalent in autism schools. Additionally, significant variations in lighting conditions highlight the need for adaptable systems to accommodate the sensory preferences and classroom activities of autistic pupils, which differ from mainstream students. These findings underscore the importance of addressing specific IEQ challenges in autism schools to improve pupil well‐being and learning outcomes. This study advocates for the development of autism‐friendly IEQ standards to guide future school design and operations.
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1)
Open AccessAssessing Indoor Environmental Quality (IEQ) Challenges in Autism Schools: Insights From Saudi Arabia′s Eastern Region
Saudi Arabia′s Vision 2030 prioritises enhancing special education services for children with special needs, including autistic pupils who are particularly sensitive to their surrounding environment. Given that autistic pupils spend significant time in schools, Indoor Environmental Quality (IEQ) is critical for their well‐being and learning outcomes yet remains underexplored. This study adopts a descriptive comparative design, using continuous monitoring and classroom activity observations to evaluate IEQ conditions in two autism schools in the Dammam region of Saudi Arabia during winter and summer. Measurements included air temperature, relative humidity, particulate matter (PM 2.5 and PM 10 ) concentrations, CO 2 levels, sound and lighting in classrooms. The IEQ parameters were measured using specific instruments installed at pupil level to accurately reflect their exposure. The findings reveal significant challenges in maintaining acceptable IEQ. PM 2.5 and PM 10 concentrations exceeded WHO guidelines, with PM 2.5 averaging 51 μ g/m 3 in School A and 30 μ g/m 3 in School B. PM 10 levels were even higher, peaking at 116 μ g/m 3 in School A and 101 μ g/m 3 in School B. These concentrations surpass those reported in mainstream schools in the same region, largely due to unique classroom activities (e.g., drawing, light physical activity) and cleaning practices (e.g., burning incense and use of sprays) prevalent in autism schools. Additionally, significant variations in lighting conditions highlight the need for adaptable systems to accommodate the sensory preferences and classroom activities of autistic pupils, which differ from mainstream students. These findings underscore the importance of addressing specific IEQ challenges in autism schools to improve pupil well‐being and learning outcomes. This study advocates for the development of autism‐friendly IEQ standards to guide future school design and operations.
- Open Access
- 1 January 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
From heritage to high performance: A scalable retrofit strategy for energy-efficient housing in Yemen’s Hot-Arid Zone
- 1 January 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
Open AccessFrom heritage to high performance: A scalable retrofit strategy for energy-efficient housing in Yemen’s Hot-Arid Zone
- 7 October 2025
- Published by Emerald Publishing in Archnet-IJAR: International Journal of Architectural Research
- p. 1-26
Integrated analysis of building form, orientation and envelope factors on energy efficiency in high-rise offices in hot-humid climates
Purpose: This study investigates the combined influence of building form, orientation, and envelope parameters on the energy performance of high-rise office buildings in hot-humid climates. Unlike prior research that examines these factors in isolation, this work emphasizes their interdependencies and introduces the Form–Orientation Energy Use Compass, a data-driven tool to guide architects in making informed early-stage design decisions. Design/methodology/approach: A comprehensive parametric simulation matrix comprising 51,840 cases was developed using EnergyPlus and DesignBuilder. About 12 idealized building forms, 16 orientations, nine window-to-wall ratios (WWR), five glazing types, three wall types and two roof types were analyzed. Key metrics include total energy use intensity (EUI), cooling loads, thermal comfort (PPD) and visual glare. Results were synthesized to produce the Form–Orientation Energy Use Compass. Findings: Building form and orientation exert a significant impact on energy performance and comfort. Compact forms, particularly C- and E-shapes with north-facing orientations (0°–15°), achieve the lowest energy intensities – reducing total EUI by 15–20 than elongated or irregular forms. In contrast, Y-shaped buildings exhibit the highest sensitivity to increasing WWR. The resulting compass visualizes these relationships and provides accessible guidance on optimal design configurations. Research limitations/implications: The study is based on simplified geometric prototypes and does not include microclimatic influences, urban shading, or structural constraints. Findings are climate-specific and may not directly generalize to other climatic contexts. Practical implications: By translating a complex dataset into an actionable visual tool, this study supports architects and urban designers in integrating energy-conscious decisions into early design phases before detailed optimization workflows. Social implications: Promoting energy-efficient form and orientation reduces operational energy demand and greenhouse gas emissions, contributing to sustainable urban growth and improving occupant comfort in dense urban environments. Originality/value: This study uniquely combines multiple interdependent design factors at a large simulation scale, filling a gap in accessible early-stage decision support for high-rise office design in hot-humid climates. The Form–Orientation Energy Use Compass bridges simulation research and practice, enabling evidence-based conceptual design.
- 7 October 2025
- Published by Emerald Publishing in Archnet-IJAR: International Journal of Architectural Research
- p. 1-26
Integrated analysis of building form, orientation and envelope factors on energy efficiency in high-rise offices in hot-humid climates
Purpose: This study investigates the combined influence of building form, orientation, and envelope parameters on the energy performance of high-rise office buildings in hot-humid climates. Unlike prior research that examines these factors in isolation, this work emphasizes their interdependencies and introduces the Form–Orientation Energy Use Compass, a data-driven tool to guide architects in making informed early-stage design decisions. Design/methodology/approach: A comprehensive parametric simulation matrix comprising 51,840 cases was developed using EnergyPlus and DesignBuilder. About 12 idealized building forms, 16 orientations, nine window-to-wall ratios (WWR), five glazing types, three wall types and two roof types were analyzed. Key metrics include total energy use intensity (EUI), cooling loads, thermal comfort (PPD) and visual glare. Results were synthesized to produce the Form–Orientation Energy Use Compass. Findings: Building form and orientation exert a significant impact on energy performance and comfort. Compact forms, particularly C- and E-shapes with north-facing orientations (0°–15°), achieve the lowest energy intensities – reducing total EUI by 15–20 than elongated or irregular forms. In contrast, Y-shaped buildings exhibit the highest sensitivity to increasing WWR. The resulting compass visualizes these relationships and provides accessible guidance on optimal design configurations. Research limitations/implications: The study is based on simplified geometric prototypes and does not include microclimatic influences, urban shading, or structural constraints. Findings are climate-specific and may not directly generalize to other climatic contexts. Practical implications: By translating a complex dataset into an actionable visual tool, this study supports architects and urban designers in integrating energy-conscious decisions into early design phases before detailed optimization workflows. Social implications: Promoting energy-efficient form and orientation reduces operational energy demand and greenhouse gas emissions, contributing to sustainable urban growth and improving occupant comfort in dense urban environments. Originality/value: This study uniquely combines multiple interdependent design factors at a large simulation scale, filling a gap in accessible early-stage decision support for high-rise office design in hot-humid climates. The Form–Orientation Energy Use Compass bridges simulation research and practice, enabling evidence-based conceptual design.
- Open Access
- 1 January 2005
- Published by King Abdulaziz University Scientific Publishing Centre in Journal of King Abdulaziz University: Engineering Sciences
- Vol. 16 (1) , 175-191
Mosque Energy Performance, Part II: Monitoring of Energy End Use in a Hot-Humid Climate
- 1 January 2005
- Published by King Abdulaziz University Scientific Publishing Centre in Journal of King Abdulaziz University: Engineering Sciences
- Vol. 16 (1) , 175-191
Open AccessMosque Energy Performance, Part II: Monitoring of Energy End Use in a Hot-Humid Climate