Laurent Lepage
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Laurent Lepage has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Abid Assali
Cardiology Department, Meir Medical Center, Tel Aviv University, Tel Aviv-Yafo 6997801, Israel
3 shared publications - Didier Tchetche
Groupe CardioVasculaire Interventionnel, Clinique Pasteur, 31076 Toulouse, France
3 shared publications - Laurent Bonfils
Groupe CardioVasculaire Interventionnel, Clinique Pasteur, 31076 Toulouse, France
3 shared publications - Nicolas Dumonteil
Groupe CardioVasculaire Interventionnel, Clinique Pasteur, 31076 Toulouse, France
3 shared publications - Ziad Arow
Groupe CardioVasculaire Interventionnel, Clinique Pasteur, 31076 Toulouse, France
3 shared publications - Akiko Masumoto
Groupe CardioVasculaire Interventionnel, Clinique Pasteur, 31076 Toulouse, France
2 shared publications
Latest Publications
- Open Access
- 11 August 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (6) , 587-590
Prospective, Single-Arm Pivotal Study for the Treatment of Subjects With Severe Symptomatic Calcific Aortic Valve Stenosis Using the Valvosoft Noninvasive Ultrasound Therapy
- 11 August 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (6) , 587-590
Open AccessProspective, Single-Arm Pivotal Study for the Treatment of Subjects With Severe Symptomatic Calcific Aortic Valve Stenosis Using the Valvosoft Noninvasive Ultrasound Therapy
- Open Access
- 24 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3239
Impact of Aortic Valve Calcium Burden on Paravalvular Leak Across Balloon-Expandable and Self-Expanding Valves: Insights from a Large TAVR Cohort
Background: Aortic valve calcium score (AVCS) is associated with an increased risk of paravalvular leak (PVL) after Transcatheter aortic valve replacement (TAVR). We aimed to evaluate the association between AVCS burden and procedural outcomes, particularly PVL, and to determine whether valve platform performance differs according to calcium burden. Methods: This study included patients with severe aortic stenosis undergoing TAVR with balloon-expandable (Sapien platform) or self-expanding (Evolut and Navitor platforms) valves. The primary endpoint was the rate of any and moderate or greater PVLs according to AVCS burden (p = 0.010), as did moderate or greater PVLs (5% vs. 3%; p = 0.011). In multivariable analysis, both SEV implantation and AVCS ≥ 3000 AU were independent predictors of moderate or greater PVL, while the interaction between AVCS burden and valve platform was not significant. When restricted to contemporary-generation valves, PVL rates were lower overall but remained higher in patients with an AVCS ≥ 3000 AU (4.4% vs. 2.4%; p = 0.001), with smaller differences between valve platforms. Conclusions: A higher AVCS is associated with increased PVLs after TAVR. BEVs showed lower rates of moderate or greater PVLs than SEVs, although no statistically significant interaction between AVCS burden and valve platform was observed. With contemporary-generation valves, overall PVL rates were reduced, and platform differences were attenuated.
- 24 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3239
Open AccessImpact of Aortic Valve Calcium Burden on Paravalvular Leak Across Balloon-Expandable and Self-Expanding Valves: Insights from a Large TAVR Cohort
Background: Aortic valve calcium score (AVCS) is associated with an increased risk of paravalvular leak (PVL) after Transcatheter aortic valve replacement (TAVR). We aimed to evaluate the association between AVCS burden and procedural outcomes, particularly PVL, and to determine whether valve platform performance differs according to calcium burden. Methods: This study included patients with severe aortic stenosis undergoing TAVR with balloon-expandable (Sapien platform) or self-expanding (Evolut and Navitor platforms) valves. The primary endpoint was the rate of any and moderate or greater PVLs according to AVCS burden (p = 0.010), as did moderate or greater PVLs (5% vs. 3%; p = 0.011). In multivariable analysis, both SEV implantation and AVCS ≥ 3000 AU were independent predictors of moderate or greater PVL, while the interaction between AVCS burden and valve platform was not significant. When restricted to contemporary-generation valves, PVL rates were lower overall but remained higher in patients with an AVCS ≥ 3000 AU (4.4% vs. 2.4%; p = 0.001), with smaller differences between valve platforms. Conclusions: A higher AVCS is associated with increased PVLs after TAVR. BEVs showed lower rates of moderate or greater PVLs than SEVs, although no statistically significant interaction between AVCS burden and valve platform was observed. With contemporary-generation valves, overall PVL rates were reduced, and platform differences were attenuated.
- Open Access
- 3 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1201
Association Between Heparin Dose, Body Mass Index, and Stroke Risk in Patients Undergoing TAVR
Background: Unfractionated heparin (UFH) is routinely administered during transcatheter aortic valve replacement (TAVR) to prevent thromboembolic complications. However, there are no clear evidence-based guidelines defining optimal heparin dosing or target activated clotting time (ACT) values. This study aimed to evaluate the association between intraprocedural UFH dosing, ACT values, and peri-procedural stroke risk in the overall population of patients undergoing TAVR, with a prespecified stratified analysis according to body mass index (BMI ≥ 30 vs. 2). Methods: This analysis enrolled consecutive individuals with severe aortic stenosis (AS) who were treated with TAVR using either balloon-expandable or self-expanding valves. The primary outcome was the occurrence of stroke during the periprocedural period in the overall population and according to BMI (2). Secondary endpoints included periprocedural parameters, clinical outcomes (in-hospital and 1-year mortality), and safety outcomes. Subgroup analysis was performed to assess stroke risk according to ACT values. Patients with atrial fibrillation or receiving chronic oral anticoagulation were excluded. Results: A total of 1045 patients underwent TAVR between 2022 and 2024, including 827 with BMI < 30 and 218 with BMI ≥ 30. The study population had a mean age of 82 ± 6 years, and 56% of patients were male. In the overall study population, the mean heparin dose was 47 U/kg and the mean ACT value was 218 s. Patients with lower BMI received higher heparin doses (50 vs. 40 U/kg, p < 0.01) and had higher ACT values (221 vs. 208 s, p < 0.01). Protamine use was low and similar between groups. Periprocedural stroke rates were low overall (1.1%) and comparable between study groups (1.2% vs. 0.9%, p = 0.71). One-year mortality was also similar (3% vs. 4%, p = 0.53), with no significant differences in other safety outcomes. Subgroup analysis by ACT (≤250 vs. >250 s) showed no difference in stroke rates (1% vs. 1.5%, p = 0.60). Conclusions: In this single-center cohort, differences in heparin dosing and ACT values were not associated with differences in peri-procedural stroke or overall procedural outcomes. However, given the low number of stroke events, these findings should be interpreted cautiously. Prospective randomized studies are needed to define optimal anticoagulation strategies during TAVR.
- 3 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1201
Open AccessAssociation Between Heparin Dose, Body Mass Index, and Stroke Risk in Patients Undergoing TAVR
Background: Unfractionated heparin (UFH) is routinely administered during transcatheter aortic valve replacement (TAVR) to prevent thromboembolic complications. However, there are no clear evidence-based guidelines defining optimal heparin dosing or target activated clotting time (ACT) values. This study aimed to evaluate the association between intraprocedural UFH dosing, ACT values, and peri-procedural stroke risk in the overall population of patients undergoing TAVR, with a prespecified stratified analysis according to body mass index (BMI ≥ 30 vs. 2). Methods: This analysis enrolled consecutive individuals with severe aortic stenosis (AS) who were treated with TAVR using either balloon-expandable or self-expanding valves. The primary outcome was the occurrence of stroke during the periprocedural period in the overall population and according to BMI (2). Secondary endpoints included periprocedural parameters, clinical outcomes (in-hospital and 1-year mortality), and safety outcomes. Subgroup analysis was performed to assess stroke risk according to ACT values. Patients with atrial fibrillation or receiving chronic oral anticoagulation were excluded. Results: A total of 1045 patients underwent TAVR between 2022 and 2024, including 827 with BMI < 30 and 218 with BMI ≥ 30. The study population had a mean age of 82 ± 6 years, and 56% of patients were male. In the overall study population, the mean heparin dose was 47 U/kg and the mean ACT value was 218 s. Patients with lower BMI received higher heparin doses (50 vs. 40 U/kg, p < 0.01) and had higher ACT values (221 vs. 208 s, p < 0.01). Protamine use was low and similar between groups. Periprocedural stroke rates were low overall (1.1%) and comparable between study groups (1.2% vs. 0.9%, p = 0.71). One-year mortality was also similar (3% vs. 4%, p = 0.53), with no significant differences in other safety outcomes. Subgroup analysis by ACT (≤250 vs. >250 s) showed no difference in stroke rates (1% vs. 1.5%, p = 0.60). Conclusions: In this single-center cohort, differences in heparin dosing and ACT values were not associated with differences in peri-procedural stroke or overall procedural outcomes. However, given the low number of stroke events, these findings should be interpreted cautiously. Prospective randomized studies are needed to define optimal anticoagulation strategies during TAVR.
- Open Access
- 30 October 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (21) , 7705
Impact of Baseline Atrial Fibrillation on Conduction Disturbances After TAVR: Insights from a Large Cohort Study
Background: Pre-existing atrial fibrillation (AF) is common among patients undergoing transcatheter aortic valve replacement (TAVR). However, evidence regarding its impact on the risk of permanent pacemaker (PPM) implantation and other conduction disturbances (CDs) after TAVR remains inconsistent. The aim of this study was to assess the effect of baseline heart rhythm on the risk of conduction abnormalities following TAVR. Methods: This study included patients with severe AS who underwent TAVR using either balloon-expandable (BEVs) or self-expanding valves (SEVs). The primary endpoint was the incidence of PPM implantation and new or worsening left bundle branch block (LBBB) after TAVR according to baseline rhythm (sinus rhythm vs. AF). Secondary endpoints were predictors of PPM implantation, LBBB, the occurrence of periprocedural stroke, and in-hospital mortality. Results: A total of 5195 TAVR patients were included: 3560 with baseline sinus rhythm and 1635 with baseline AF. PPM implantation was more frequent in patients with AF than in those with sinus rhythm (17% vs. 15%, p = 0.033), whereas new or worsening LBBB was less common (11% vs. 14%, p = 0.026). After adjustment with multivariable logistic regression, these associations were no longer statistically significant (PPM implantation: OR 1.156, 95% CI 0.969–1.379, p = 0.108; new or worsening LBBB: OR 0.826, 95% CI 0.676–1.010, p = 0.062). Independent peri-procedural predictors of PPM implantation included baseline first-degree AV block, pre-procedural RBBB, the use of self-expandable valves, implantation of larger valve sizes (≥23 mm), and the need for valve repositioning. Conclusions: In this large cohort, baseline AF was not associated with an increased risk of PPM implantation or new onset LBBB compared with sinus rhythm. These findings suggest that baseline rhythm alone should not be considered an independent predictor of PPM implantation or CDs following TAVR.
- 30 October 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (21) , 7705
Open AccessImpact of Baseline Atrial Fibrillation on Conduction Disturbances After TAVR: Insights from a Large Cohort Study
Background: Pre-existing atrial fibrillation (AF) is common among patients undergoing transcatheter aortic valve replacement (TAVR). However, evidence regarding its impact on the risk of permanent pacemaker (PPM) implantation and other conduction disturbances (CDs) after TAVR remains inconsistent. The aim of this study was to assess the effect of baseline heart rhythm on the risk of conduction abnormalities following TAVR. Methods: This study included patients with severe AS who underwent TAVR using either balloon-expandable (BEVs) or self-expanding valves (SEVs). The primary endpoint was the incidence of PPM implantation and new or worsening left bundle branch block (LBBB) after TAVR according to baseline rhythm (sinus rhythm vs. AF). Secondary endpoints were predictors of PPM implantation, LBBB, the occurrence of periprocedural stroke, and in-hospital mortality. Results: A total of 5195 TAVR patients were included: 3560 with baseline sinus rhythm and 1635 with baseline AF. PPM implantation was more frequent in patients with AF than in those with sinus rhythm (17% vs. 15%, p = 0.033), whereas new or worsening LBBB was less common (11% vs. 14%, p = 0.026). After adjustment with multivariable logistic regression, these associations were no longer statistically significant (PPM implantation: OR 1.156, 95% CI 0.969–1.379, p = 0.108; new or worsening LBBB: OR 0.826, 95% CI 0.676–1.010, p = 0.062). Independent peri-procedural predictors of PPM implantation included baseline first-degree AV block, pre-procedural RBBB, the use of self-expandable valves, implantation of larger valve sizes (≥23 mm), and the need for valve repositioning. Conclusions: In this large cohort, baseline AF was not associated with an increased risk of PPM implantation or new onset LBBB compared with sinus rhythm. These findings suggest that baseline rhythm alone should not be considered an independent predictor of PPM implantation or CDs following TAVR.