ZGZhaohui Geng

Zhaohui Geng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhaohui Geng has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A lightweight deep convolutional neural network for detecting artifacts in continuous EEG signals

    by Evans Nyanney, Parthasarathy D. Thirumala, Shyam Visweswaran, Zhaohui Geng


  • Open Access

    Detection-Guided Artifact Removal for Clinical EEG: A Deep Learning Framework

    by Evans Nyanney, Parthasarathy D. Thirumala, Shyam Visweswaran, Zhaohui Geng

    Objective: We developed and validated a detection-guided artifact removal framework for clinical electroencephalography (EEG). It corrects only the contaminated segments and preserves artifact-free data. Approach: The framework employs convolutional neural network (CNN) detectors trained on the Temple University Hospital (TUH) Artifact Corpus of 150 recordings from 105 patients. For eye movement artifacts (20 second windows), it uses independent component analysis (ICA) and canonical correlation analysis (CCA). For muscle artifacts (5 second windows), it employs wavelet thresholding and empirical mode decomposition (EMD). For non-physiological artifacts (1 second windows), it utilizes spherical spline interpolation and artifact subspace reconstruction (ASR). Removal is applied exclusively to detector-flagged windows, and unflagged windows remain unchanged. In a held-out test set of 21 patients and 30 recordings, we compared selective and global removal using correlation, root mean squared error (RMSE), and peak signal-to-noise ratio (PSNR). Main results: Selective removal outperformed global removal in all six methods and 18 metric comparisons, with a p -value of less than 10 −105 . Selective processing maintained a clean-segment correlation above 0.987, whereas global removal reduced the correlation to values as low as 0.39 for CCA and 0.47 for ASR. CCA removed 74.6% of the eye movement artifact amplitude, EMD removed 99.8% of the high-frequency (30–40 Hz) muscle contamination, and ASR reduced the non-physiological artifact amplitude by 37.1%. The preservation of artifact-free windows remained high for all methods and indicated minimal distortion of the clean EEG. Significance: Detection-guided selective removal addresses a significant limitation of global correction pipelines that can remove clean EEG signals. This framework automates artifact removal without manual review and preserves the signal fidelity for clinical interpretation. Its modular design facilitates integration into real-time monitoring systems for acute and perioperative care.


  • Open Access

    A Deep Lightweight Convolutional Neural Network for Detecting Artifacts in Continuous EEG Signals

    by Evans Nyanney, Parthasarathy D. Thirumala, Shyam Visweswaran, Zhaohui Geng

    Objective: This study aimed to develop and validate a system of specialized deep lightweight convolutional neural networks (CNN) to accurately detect specific artifact classes and demonstrate their advantage over traditional rule-based methods. Methods: Three distinct CNN systems were trained on the Temple University Hospital EEG Artifact Corpus to identify eye movement, muscle-related and non-physiological artifacts, with each system optimized for an ideal temporal window size. The performance of the proposed system was compared with standard rule-based clinical detection methods in a held-out test set. Results: The CNN systems significantly outperformed rule-based methods, with F1-score improvements ranging from +11.2% to +44.9%. Importantly, the results revealed distinct optimal temporal window lengths for each artifact type: 20s for eye movements (ROC AUC 0.975%), 5s for muscle activity (Accuracy 93.2%), and 1s for non-physiological artifact(F1-score 77.4%). Conclusion: The results show that specialized, artifact-specific CNNs provide a more consistent and accurate solution for automated EEG artifact detection than traditional rule-based approaches Significance: This study establishes a new benchmark for automated EEG quality control by validating one of the first open-source, specialized CNN systems for three distinct artifact classes, both high sensitivity and specificity.

  • Tolerance estimation and metrology for reverse engineering based remanufacturing systems

    by Zhaohui Geng, Bopaya Bidanda

    Tolerances are critical to the product’s design, manufacturing, and quality. However, tolerances are often overlooked in a reverse engineering (RE) process for industrial applications, especially in legacy parts or spare parts remanufacturing. Ignoring tolerances could either unnecessarily call for high precision remanufacturing processes or make the reproduced parts unqualified. Additive manufacturing (AM) techniques are used in remanufacturing applications because of their ability to manufacturing intricated parts. Due to its layer-by-layer fabrication nature, the metrology for AM-created parts is drastically different when compared to traditional feature-generation processes. In this study, we first propose a novel way to classify manufacturing processes based on whether they directly identify or generate features, which could profoundly affect their metrology tools. Next, a systematic geometric inspection and tolerance estimation methodology for the RE system is proposed. A set of tools is developed to extract various geometric dimensional values from the point clouds based on their tolerancing types. Moreover, based on the domain knowledge in production process design and planning, methods are developed to estimate empirical tolerances from a small batch of legacy parts. Comparisons of empirical tolerances of real machined parts to their designed tolerances are presented to evaluate the performance of the proposed framework.