Anning Niu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anning Niu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jiaqiang Yang
Zhejiang University
3 shared publications - Liang Yan
College of Electrical Engineering, Zhejiang University, Hangzhou, China
2 shared publications - Rafik Ighil Nessouk
College of Electrical Engineering, Zhejiang University, Hangzhou, China
2 shared publications - Zhihan Wu
College of Electrical Engineering, Zhejiang University, Hangzhou, China
2 shared publications Xiaojun Zhang
College of Automation and Electrical Engineering, Zhejiang University of Science and Technology, Hangzhou, China
1 shared publication- Yunlong Chen
College of Electrical Engineering, Zhejiang University, Hangzhou, China
1 shared publication
Latest Publications
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. PP (00189464) , 1
Electromagnetic Analysis of SPM Using Sub-domain Model Based on the Magnetic Scalar Potential Field
This paper presents an improved analytical sub-domain model based on the magnetic scalar potential (MSP) for analyzing the no-load and on-load magnetic fields and performance of the surface-mounted permanent magnet motor (SPM). In this approach, the magnet is treated as a polarised magnetic source, while the armature current is represented by the MSP boundary condition. Analytical expressions for each sub-domain are derived using Poisson’s and Laplace’s equations. The proposed analytical model is validated through finite element simulations and compared with the classical sub-domain model based on the magnetic vector potential (MVP). The results demonstrate that the proposed method achieves high accuracy for key performance indicators, including the magnetic field in the air-gap, torque ripple, and induced voltage. Compared with the MVP-based sub-domain model, the proposed sub-domain model treats the magnetic field as a scalar field, similar to that of an electric or thermal field, which enhances the understanding of magnetic field behavior. Furthermore, this model has the potential for improved coupling analysis with magnetic circuit models, making it suitable for complicated magnetic field analysis problems.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. PP (00189464) , 1
Electromagnetic Analysis of SPM Using Sub-domain Model Based on the Magnetic Scalar Potential Field
This paper presents an improved analytical sub-domain model based on the magnetic scalar potential (MSP) for analyzing the no-load and on-load magnetic fields and performance of the surface-mounted permanent magnet motor (SPM). In this approach, the magnet is treated as a polarised magnetic source, while the armature current is represented by the MSP boundary condition. Analytical expressions for each sub-domain are derived using Poisson’s and Laplace’s equations. The proposed analytical model is validated through finite element simulations and compared with the classical sub-domain model based on the magnetic vector potential (MVP). The results demonstrate that the proposed method achieves high accuracy for key performance indicators, including the magnetic field in the air-gap, torque ripple, and induced voltage. Compared with the MVP-based sub-domain model, the proposed sub-domain model treats the magnetic field as a scalar field, similar to that of an electric or thermal field, which enhances the understanding of magnetic field behavior. Furthermore, this model has the potential for improved coupling analysis with magnetic circuit models, making it suitable for complicated magnetic field analysis problems.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4850-4861
Regularized Autocorrelated Errors Variable Step Size FxLMS Algorithm-Based Active Noise Control
In this article, a regularized autocorrelated errors variable step size (VSS) filtered-x least mean square (RAEVSS-FxLMS) algorithm is proposed for adaptive active noise control (ANC) systems. Initially, the inverse filter principle is employed to derive the secondary path transfer function for frequency equalization. The proposed algorithm is subsequently integrated into the loudspeaker equalization path to establish a novel single-channel adaptive filtering model. In addition, an error autocorrelation function is incorporated into the constraints with the objective of enhancing the antiinterference performance of the model. Concurrently, the convergence and robustness of the algorithm are subjected to theoretical analysis. The proposed control scheme has been demonstrated to effectively address the modeling error introduced by noncorrelated noise, as well as solve the frequency distortion caused by the nonlinearity of acoustic units. Furthermore, an ANC test platform including software and hardware components is designed in accordance with the noise characteristics to experimentally evaluate the effectiveness of the proposed ANC method. Finally, the experimental results of the real-time noise reduction based on the DSP solution demonstrate that the proposed control strategy outperforms the conventional algorithm in addressing range hood noise under tested conditions.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4850-4861
Regularized Autocorrelated Errors Variable Step Size FxLMS Algorithm-Based Active Noise Control
In this article, a regularized autocorrelated errors variable step size (VSS) filtered-x least mean square (RAEVSS-FxLMS) algorithm is proposed for adaptive active noise control (ANC) systems. Initially, the inverse filter principle is employed to derive the secondary path transfer function for frequency equalization. The proposed algorithm is subsequently integrated into the loudspeaker equalization path to establish a novel single-channel adaptive filtering model. In addition, an error autocorrelation function is incorporated into the constraints with the objective of enhancing the antiinterference performance of the model. Concurrently, the convergence and robustness of the algorithm are subjected to theoretical analysis. The proposed control scheme has been demonstrated to effectively address the modeling error introduced by noncorrelated noise, as well as solve the frequency distortion caused by the nonlinearity of acoustic units. Furthermore, an ANC test platform including software and hardware components is designed in accordance with the noise characteristics to experimentally evaluate the effectiveness of the proposed ANC method. Finally, the experimental results of the real-time noise reduction based on the DSP solution demonstrate that the proposed control strategy outperforms the conventional algorithm in addressing range hood noise under tested conditions.
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (5) , 5816-5827
Decoupled Virtual Vector-Based Predictive Current Control of Dual Three-Phase PMSMs With Model-Free Harmonic Current Suppression
Finite control set model predictive control (FCSMPC) based on virtual vectors for dual three-phase permanent magnet synchronous machines inherently lacks control capability in the x–y subspace, resulting in an inability to suppress unmodeled disturbances decoupled in this subspace and leading to severe current distortion. Existing studies have incorporated x–y current prediction to compensate for disturbances in a closedloop manner but require prior knowledge of the stator leakage inductance. Mismatches in this parameter degrade harmonic suppression performance. In this work, we introduce a modelfree solution that relies solely on measured input/output data, eliminating dependence on x–y subspace model parameters. To enable the linear mapping between the input/output data to describe the rich periodic disturbances in the x–y subspace, sine and cosine feature excitations are added to the regressor. The enhanced data model better approximates the physical model for predicting x–y current dynamics. A low-complexity normalized least mean square (NLMS) algorithm is employed to optimize the regression coefficients, allowing the proposed method to be implemented on a digital signal processor with 10kHz sampling frequency. Experimental results validate the superiority of the proposed strategy over other existing methods.
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (5) , 5816-5827
Decoupled Virtual Vector-Based Predictive Current Control of Dual Three-Phase PMSMs With Model-Free Harmonic Current Suppression
Finite control set model predictive control (FCSMPC) based on virtual vectors for dual three-phase permanent magnet synchronous machines inherently lacks control capability in the x–y subspace, resulting in an inability to suppress unmodeled disturbances decoupled in this subspace and leading to severe current distortion. Existing studies have incorporated x–y current prediction to compensate for disturbances in a closedloop manner but require prior knowledge of the stator leakage inductance. Mismatches in this parameter degrade harmonic suppression performance. In this work, we introduce a modelfree solution that relies solely on measured input/output data, eliminating dependence on x–y subspace model parameters. To enable the linear mapping between the input/output data to describe the rich periodic disturbances in the x–y subspace, sine and cosine feature excitations are added to the regressor. The enhanced data model better approximates the physical model for predicting x–y current dynamics. A low-complexity normalized least mean square (NLMS) algorithm is employed to optimize the regression coefficients, allowing the proposed method to be implemented on a digital signal processor with 10kHz sampling frequency. Experimental results validate the superiority of the proposed strategy over other existing methods.