DLDongwoo Lee

Dongwoo Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dongwoo Lee has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Normal Hearing Thresholds in Korean Adults Aged 20–79 Years: Establishing Reference Values and Comparison With International Organization for Standardization 7029:2017

    by Dongwoo Lee, Chanbeom Kwak, Junghee Sagong, Donghyeok Lee, Yuseon Byun, Young Joon Seo, In-Ki Jin

    Purpose: This study aimed to establish age-specific and ear-specific normative hearing thresholds for Korean adults aged 20–79 years, examining interaural asymmetry, sex-related variations, internal consistency, and comparing findings with International Organization for Standardization (ISO) 7029:2017. Method: A total of 1,409 participants (382 men, 1,027 women) with otologically normal hearing were included in this multicenter cross-sectional study (2021–2024). Ear-specific audiometry was performed at standard frequencies (250–8000 Hz) with calibrated equipment across four hospitals in South Korea. Measurement equivalence across institutions was confirmed through equivalence testing. Results: Measurement equivalence was confirmed across institutions (± 4-dB equivalence bounds). Age-specific normative hearing thresholds were established for Korean adults. Significant interaural asymmetry was observed, with right ear thresholds higher than left ear thresholds by an average of 2.8 dB in women and 1.7 dB in men ( p < .05), particularly in younger adults (20s–50s). Sex differences were significant at specific frequencies and age groups, with men demonstrating higher thresholds than women. Internal consistency varied significantly by sex and age group, with men showing lower consistency in middle-aged groups (40s–50s). Korean hearing thresholds diverged significantly from ISO 7029:2017 medians across most age groups and frequencies (elevations: 2.0–19.0 dB, p < .05). Minimum required sample sizes varied substantially across demographic subgroups. Conclusions: This study provides age-specific and ear-specific normative hearing thresholds for Korean adults. The findings revealed statistically significant interaural differences and deviations from ISO standards, underscoring the importance of population-specific reference data and updating international standards with contemporary cohort-specific information.

  • Open Access

    Electroencephalographic Biomarkers in Tinnitus: A Narrative Review of Current Approaches and Clinical Perspectives

    by Hyeonsu Oh, Dongwoo Lee, Jae-Kwon Song, Seunghyeon Baek, In-Ki Jin

    Background/Objectives: Tinnitus causes significant cognitive and emotional distress; however, its clinical assessment mostly relies on subjective measures without evaluation of objective indices. In this narrative review, we examined the potential of electroencephalography (EEG)-based neurophysiological markers as objective biomarkers in tinnitus assessment. Methods: The Web of Science, PubMed, EMBASE, and MEDLINE databases were searched to identify research articles on EEG-based analysis of individuals with tinnitus. Studies in which treatment and control groups were compared across four analytical domains (spectral power analysis, functional connectivity, microstate analysis, and entropy measures) were included. Qualitative synthesis was conducted to elucidate neurophysiological mechanisms, methodological characteristics, and clinical implications. Results: Analysis of 18 studies (n = 1188 participants) revealed that tinnitus is characterized by distributed neural dysfunction that extends beyond the auditory system. Spectral power analyses revealed sex-dependent, frequency-specific abnormalities across distributed brain regions. Connectivity analyses demonstrated elevated long-range coupling in high-frequency bands concurrent with diminished low-frequency synchronization. Microstate analyses revealed alterations in spatial configuration and transition probabilities. Entropy quantification indicated elevated complexity, particularly in the frontal and auditory cortices. Conclusions: EEG-derived neurophysiological markers demonstrate associations with tinnitus in group analyses and show potential for elucidating pathophysiological mechanisms. However, significant limitations, including low spatial resolution, small sample sizes, methodological heterogeneity, and lack of validation for individual-level diagnosis or treatment prediction, highlight the need for cautious interpretation. Standardized analytical protocols, larger validation studies, multimodal neuroimaging integration, and demonstration of clinical utility in prospective trials are required before EEG markers can be established as biomarkers for tinnitus diagnosis and management.


  • Open Access

    Recent Technological Trends in Hearing Aids: Advanced Features and Clinical Validation by Global Manufacturers

    by Jimin Jeong, Dongwoo Lee, Hongseok Yang, Hyungjun Sim, Hyeonsu Oh, Jaegwon Song, Jungsuk Yang, Sangmin Park, Seunghyeon Baek, Sunmi Ma, et al.

    This review systematically analyzed the latest technological trends among global hearing aid manufacturers to provide an overview of current advancements and suggest future research directions. Technical documents from six major companies-Beltone (GN Hearing, Chicago, IL, USA), Oticon (Demant, Smørum, Denmark), Phonak (Sonova, Stäfa, Switzerland), Signia (WS Audiology, Iselin, NJ, USA), Starkey (Starkey, Eden Prairie, MN, USA), and Widex (WS Audiology, Lynge, Denmark)-were reviewed. Hearing aid technologies were categorized into four domains: advanced hearing optimization, tinnitus management, application features, and power management. The key features, operational principles, clinical evidence, and unique characteristics of each manufacturer were analyzed. Recent innovations incorporate artificial intelligence, deep neural networks, wireless connectivity, and real-time signal processing, enabling speech enhancement, noise reduction, and personalized experiences. Tinnitus solutions focus on sound therapy and individualized masking. Application-based developments include health tracking, remote fitting, and device maintenance, while power management enhances battery efficiency. Clinical findings demonstrate significant improvement in speech intelligibility, comfort, and user satisfaction. Advancements in hearing aids have markedly improved quality of life for individuals with hearing loss. To ensure validated clinical outcomes and reliability, independent research free from manufacturer bias remains essential in this fast-evolving field.