Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kazumasa Tatsumi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of Mold Design and Molding Conditions on the Optical Properties of Contact Lenses

    by Kazumasa Tatsumi, Kentaro Saeki, Shin Kubota, Yoshikatsu Kaneda, Kenji Uno, Kazuhiko Ohnuma, Tatsuo Shiina

    Injection molding is essential for mass-producing soft contact lenses, yet molding-induced deformation remains a decisive factor for optical quality. This study systematically evaluated the impact of resin mold design factors (optical zone (OZ) radius of curvature and resin mold thickness) and injection molding parameters (holding pressure and injection speed) on the properties of a dry-state lens (dry lens) using an L18 orthogonal array. The results demonstrated that optimizing the resin mold thickness to 0.9 mm reduced astigmatism by approximately 95%, while high holding pressure and low injection speed improved structural stability. Notably, the findings suggest that the refractive power of the dry lens is more strongly governed by macro-level curvature fluctuations and internal stress distributions arising from the resin mold thickness and shape than by the wavefront aberrations of the resin mold itself. Designs with a smaller radius of curvature (R = 6.5 mm) exhibited substantial power deviations of up to +2.8 D, whereas deviations remained within ±0.2 D for designs with a larger radius of curvature (R = 8.5 mm). For high-precision lens manufacturing, it is indispensable to incorporate a resin mold design that accounts for deformations induced during molding. This study provides comprehensive guidelines for achieving high-quality products by detailing the relationship between injection molding and design.

  • Open Access

    Evaluation Method for Resin Mold Using Reflective Wavefront Sensor

    by Kazumasa Tatsumi, Kentaro Saeki, Shin Kubota, Yoshikatsu Kaneda, Kenji Uno, Kazuhiko Ohnuma, Tatsuo Shiina

    Recent advances in molding technology have enabled the fabrication of plastic molded components with complex geometries. In contact lens (CL) manufacturing, a double-sided molding process using resin molds is employed, in which the front and back surfaces of the lens are replicated through injection molding. However, thermal deformation during polymerization can alter the mold shape, thereby affecting the optical characteristics of the final lenses. This study proposes a high-precision optical evaluation method for resin molds used in contact lens (CL) manufacturing, utilizing a reflective wavefront sensor and optical coherence tomography (OCT). The wavefront sensor demonstrated high measurement accuracy (≈1/100λ) and reproducibility (≈1/200λ) as confirmed using reference samples, and yielded values of approximately 0.012–0.015 μm for the resin molds. Five mold designs with radii of curvature ranging from 6.500 to 8.500 mm were evaluated, revealing that Zernike coefficients varied depending on design and thermal treatment conditions. In particular, astigmatism (Z04) and coma aberrations (Z07) exhibited pronounced trends. A strong correlation was also observed between the Zernike coefficient Z07 and the mold thickness asymmetry measured by OCT. When the thickness difference increased by 2.3 times due to thermal treatment, Z07 increased to 1.9 times. In contrast, Z04 showed no consistent trend and exhibited significant variability (standard deviation > 0.5 μm) after polymerization. The proposed method enables precise detection of subtle shape variations and aberrations, providing valuable feedback for optimizing molding conditions and improving the quality of contact lens production. Furthermore, this method can also be applied to the quality evaluation of other optical components.