Xin Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xin Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Wu Chen
Southeast University
2 shared publications - Pengfei Yao
School of Electrical Engineering, Southeast University, Nanjing 210096, China
1 shared publication - Teng Zhang
School of Electrical Engineering, Southeast University, Nanjing 210096, China
1 shared publication - Tianming Zhu
School of Electrical Engineering, Southeast University, Nanjing 210096, China
1 shared publication - Xiaochun Mou
School of Electrical and Engineering, Southeast University, Nanjing 210096, China
1 shared publication - Yibin Tao
Jiangsu Engineering Technology Research Center for Energy Storage Conversion and Application, China Electric Power Research Institute, Nanjing 210003, China
1 shared publication
Latest Publications
- Open Access
- 23 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 4918
Design and Implementation of a High-Gain Bidirectional CLLC Resonant Converter for Photovoltaic Energy Storage Systems
In residential photovoltaic (PV) energy storage systems, the bidirectional DC–DC converter between the DC bus and the battery must operate efficiently over wide input- and output-voltage ranges. This paper presents the design and implementation of a high-gain bidirectional CLLC resonant converter rated for 4.8 kW. The converter operating principle under pulse frequency modulation (PFM) is described, and its voltage gain is derived using first harmonic approximation (FHA). Resonant tank parameter selection considers voltage gain, soft switching, and gain monotonicity. To improve modulation accuracy and coordinate register updates under PFM, a high-precision implementation based on high-resolution pulse-width modulation (HRPWM) is proposed. Global loading synchronizes supported PWM shadow registers, while high-resolution period updates are coordinated separately. A converter loss model guides the forced-air cooling design of a parallel-fin heatsink, assessed by electrothermal co-simulation at 6 kW output power and long-duration tests at 4.8 kW battery-port power. Experimental results show that the peak efficiency of the prototype reaches 97.45% in charging mode and 96.66% in discharging mode.
- 23 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 4918
Open AccessDesign and Implementation of a High-Gain Bidirectional CLLC Resonant Converter for Photovoltaic Energy Storage Systems
In residential photovoltaic (PV) energy storage systems, the bidirectional DC–DC converter between the DC bus and the battery must operate efficiently over wide input- and output-voltage ranges. This paper presents the design and implementation of a high-gain bidirectional CLLC resonant converter rated for 4.8 kW. The converter operating principle under pulse frequency modulation (PFM) is described, and its voltage gain is derived using first harmonic approximation (FHA). Resonant tank parameter selection considers voltage gain, soft switching, and gain monotonicity. To improve modulation accuracy and coordinate register updates under PFM, a high-precision implementation based on high-resolution pulse-width modulation (HRPWM) is proposed. Global loading synchronizes supported PWM shadow registers, while high-resolution period updates are coordinated separately. A converter loss model guides the forced-air cooling design of a parallel-fin heatsink, assessed by electrothermal co-simulation at 6 kW output power and long-duration tests at 4.8 kW battery-port power. Experimental results show that the peak efficiency of the prototype reaches 97.45% in charging mode and 96.66% in discharging mode.
- Open Access
- 1 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (21) , 4310
Refined Fuzzy-Control-Based VSG Control Strategy for Flexible Interconnection Devices in Distribution Grid
In this paper, virtual synchronous generator (VSG) technology is innovatively introduced into the distributor-unified power flow controller (D-UPFC) control to simulate the power generation characteristics of the synchronous generator. Concepts such as inertia and damping in the synchronous generator are introduced into power electronic equipment to provide voltage and frequency support for the system. The VSG control system, which specifically includes the virtual governor, the virtual excitation regulator, and the construction of the VSG model, is designed first. Then, the overall control combining the VSG and the series converter in D-UPFC is discussed. Finally, based on the influence of moment of inertia and damping coefficient on the response parameters, a VSG parameter adaptive control strategy based on refined fuzzy control was proposed. The simulation shows that this strategy can effectively reduce the active overshot and frequency deviation in the dynamic process of the system, eliminate secondary oscillations, and improve the dynamic response capability.
- 1 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (21) , 4310
Open AccessRefined Fuzzy-Control-Based VSG Control Strategy for Flexible Interconnection Devices in Distribution Grid
In this paper, virtual synchronous generator (VSG) technology is innovatively introduced into the distributor-unified power flow controller (D-UPFC) control to simulate the power generation characteristics of the synchronous generator. Concepts such as inertia and damping in the synchronous generator are introduced into power electronic equipment to provide voltage and frequency support for the system. The VSG control system, which specifically includes the virtual governor, the virtual excitation regulator, and the construction of the VSG model, is designed first. Then, the overall control combining the VSG and the series converter in D-UPFC is discussed. Finally, based on the influence of moment of inertia and damping coefficient on the response parameters, a VSG parameter adaptive control strategy based on refined fuzzy control was proposed. The simulation shows that this strategy can effectively reduce the active overshot and frequency deviation in the dynamic process of the system, eliminate secondary oscillations, and improve the dynamic response capability.