Sébastien Lasvaux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sébastien Lasvaux has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Hollberg
Chalmers University of Technology
1 shared publication - Alina Galimshina
ETH Zurich
1 shared publication - Bruno Sudret
Chair of Risk, Safety and Uncertainty Quantification ETH Zürich Stefano-Franscini-Platz 5 8093 Zürich Switzerland
1 shared publication - Daia Zwicky
Institute of Construction and Environmental Technologies iTEC, University of Applied Sciences and Arts Western Switzerland HES-SO
1 shared publication Guillaume Habert
1 shared publication- Guillaume Habert
ETH Zurich
1 shared publication
Latest Publications
- Open Access
- 1 November 2025
- Published by Elsevier in Energy and Buildings
- Vol. 350
What really matters when benchmarking carbon mitigation measures against carbon budget-aligned targets for buildings?
- 1 November 2025
- Published by Elsevier in Energy and Buildings
- Vol. 350
Open AccessWhat really matters when benchmarking carbon mitigation measures against carbon budget-aligned targets for buildings?
- Open Access
- 6 January 2022
- Published by Trans Tech Publications, Ltd. in Construction Technologies and Architecture
- Vol. 1, 466-471
Earth Plastered Wall Heating as a Low-Emitting, Cost-Effective and Robust Energy System for Building Renovation
Renovation of the building stock in Europe is urgent to decrease the environmental impact from the building sector and meet the United Nations climate action goals. However, it is often hard to define a robust scenario for a renovation due to numerous uncertainties, which occur during the production, operation and end-of-life stage. One can cite the loss of performance of insulation and heating systems, the replacement time of installation or the future energy prices as well as the future climate. The replacement of oil boilers with heat pumps has shown a good performance regarding costs and greenhouse gas emissions. However, due to the flow and return temperature differences, often the current heat distribution system needs to be replaced as well, which is normally done with conventional radiators or floor heating. In this paper, we analyse a new possibility of a heat distribution system with earth plastered wall. We develop a methodology on the integrated assessment of life cycle assessment (LCA) and life cycle cost analysis (LCCA) for the renovation scenarios and adapt the analysis of the heat pump renovation solution with conventional radiators system and the earth plastered wall for two typical residential buildings located in Switzerland. Through rigorous statistical treatment, we then propagate the possible sources of uncertainty and perform the uncertainty quantification using polynomial chaos expansion to compare the distributions of two outcomes. The results show that the solution with the earth plaster has lower overall environmental impacts and costs. It has also been noticed that the solution with the earth plaster is more robust in investment cost and embodied emissions compared to the solution with the conventional radiators.
- 6 January 2022
- Published by Trans Tech Publications, Ltd. in Construction Technologies and Architecture
- Vol. 1, 466-471
Open AccessEarth Plastered Wall Heating as a Low-Emitting, Cost-Effective and Robust Energy System for Building Renovation
Renovation of the building stock in Europe is urgent to decrease the environmental impact from the building sector and meet the United Nations climate action goals. However, it is often hard to define a robust scenario for a renovation due to numerous uncertainties, which occur during the production, operation and end-of-life stage. One can cite the loss of performance of insulation and heating systems, the replacement time of installation or the future energy prices as well as the future climate. The replacement of oil boilers with heat pumps has shown a good performance regarding costs and greenhouse gas emissions. However, due to the flow and return temperature differences, often the current heat distribution system needs to be replaced as well, which is normally done with conventional radiators or floor heating. In this paper, we analyse a new possibility of a heat distribution system with earth plastered wall. We develop a methodology on the integrated assessment of life cycle assessment (LCA) and life cycle cost analysis (LCCA) for the renovation scenarios and adapt the analysis of the heat pump renovation solution with conventional radiators system and the earth plastered wall for two typical residential buildings located in Switzerland. Through rigorous statistical treatment, we then propagate the possible sources of uncertainty and perform the uncertainty quantification using polynomial chaos expansion to compare the distributions of two outcomes. The results show that the solution with the earth plaster has lower overall environmental impacts and costs. It has also been noticed that the solution with the earth plaster is more robust in investment cost and embodied emissions compared to the solution with the conventional radiators.