Francesco Latino
Research Subjects
Francesco Latino has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Costanzo Palmisciano
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Ponzio, 34/5, Milan, 20133, ITALY
3 shared publications - Andrea Farabbi
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Ponzio 34/5, Milano, Milano, 20133, Italy
3 shared publications - Luca Mainardi
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
3 shared publications - Matteo Rossi
Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy
3 shared publications - Pietro Cerveri
Università di Pavia, Via A. Ferrata, 5, Pave, 27100, Italy
3 shared publications - Athul Krishnan
I-Labs, Electrical Engineering and Computer Science, Indian Institute of Science Education and Research Bhopal, Madhya Pradesh, India
2 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (9) , 095010
A gated artifact management pipeline for low-density eyewear EEG
Objective . To develop an artifact-management method suitable for low-density, dry-electrode electroencephalogram (EEG) recorded from a wearable eyewear platform, enabling artifact detection, classification, and correction while avoiding unnecessary processing of clean neural activity. Approach . A gated two-stage pipeline is proposed in which a lightweight gate classifier first identifies artifact-contaminated EEG windows and selectively triggers further processing only when needed. The complete pipeline combines: (i) a time-domain feature-based detector, (ii) a convolutional–recurrent network for three-class artifact discrimination (eye blinks, horizontal eye movements, facial movements), and (iii) a U-Net-based denoising autoencoder. Main results . Evaluated on the eyewear EEG dataset (29 subjects) using a leave-one-subject-out scheme, the gate classifier achieved a balanced accuracy of 0.89. The artifact classifier reached a balanced accuracy of 0.84 with a median macro-F1 of 0.83. The denoiser achieved a median normalized RMSE lower than 0.20 and a spectral cosine similarity above 0.84. In the end-to-end evaluation, the pipeline achieved a median normalized RMSE of 0.19 and a spectral cosine similarity of 0.89. Evaluation on an independent external benchmark showed that the proposed pipeline maintained a slightly lower gate detection performance (balanced accuracy 0.82) and achieved higher two-class classification performance. The denoising performance was comparable to that obtained on the dataset collected for this study, with absolute median differences not exceeding 0.04 for both normalized RMSE and spectral cosine similarity. Significance . These results support the effectiveness of the proposed approach for artifact management in wearable eyewear EEG, while maintaining a design compatible with resource-constrained wearable implementations.
- 29 September 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (9) , 095010
Open AccessA gated artifact management pipeline for low-density eyewear EEG
Objective . To develop an artifact-management method suitable for low-density, dry-electrode electroencephalogram (EEG) recorded from a wearable eyewear platform, enabling artifact detection, classification, and correction while avoiding unnecessary processing of clean neural activity. Approach . A gated two-stage pipeline is proposed in which a lightweight gate classifier first identifies artifact-contaminated EEG windows and selectively triggers further processing only when needed. The complete pipeline combines: (i) a time-domain feature-based detector, (ii) a convolutional–recurrent network for three-class artifact discrimination (eye blinks, horizontal eye movements, facial movements), and (iii) a U-Net-based denoising autoencoder. Main results . Evaluated on the eyewear EEG dataset (29 subjects) using a leave-one-subject-out scheme, the gate classifier achieved a balanced accuracy of 0.89. The artifact classifier reached a balanced accuracy of 0.84 with a median macro-F1 of 0.83. The denoiser achieved a median normalized RMSE lower than 0.20 and a spectral cosine similarity above 0.84. In the end-to-end evaluation, the pipeline achieved a median normalized RMSE of 0.19 and a spectral cosine similarity of 0.89. Evaluation on an independent external benchmark showed that the proposed pipeline maintained a slightly lower gate detection performance (balanced accuracy 0.82) and achieved higher two-class classification performance. The denoising performance was comparable to that obtained on the dataset collected for this study, with absolute median differences not exceeding 0.04 for both normalized RMSE and spectral cosine similarity. Significance . These results support the effectiveness of the proposed approach for artifact management in wearable eyewear EEG, while maintaining a design compatible with resource-constrained wearable implementations.
- Open Access
- 12 May 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (5) , 055011
Turning glasses into sensors: capacitive facial expression recognition under frame geometry constraints
Objective. Wearable facial expression recognition requires sensing modalities that are unobtrusive, illumination-independent, and compatible with everyday eyewear form factors. Existing optical and electromyographic approaches are limited by line-of-sight requirements, skin contact, or restricted action unit (AU) coverage. This work investigates the feasibility of non-contact capacitive sensing for facial muscle activity monitoring within the strict geometric constraints of standard eyewear. Approach. We developed FERGlasses, integrating eight loading-mode capacitive channels via a custom flexible PCB and active shielding to detect skin-to-frame displacement. A validation study with 40 participants was conducted to elicit seven facial action coding system-defined AUs. Signal fidelity was assessed using independent Random Forest regressors and benchmarked against commercial optical-proximity (OCOsense) and computer-vision (Py-Feat) standards. Main results. The system demonstrated high agreement for upper-face activity, achieving median cosine similarities of 0.97 for the Outer Brow Raiser (AU02) and 0.87 for the Nose Wrinkler (AU09), while lower-face actions such as the Chin Raiser (AU17) yielded a median of 0.33, consistent with mechanical signal attenuation along the frame. Channel-ablation analysis quantified the specific anatomical contributions of each electrode group, identifying eyebrow and rhinion sensors as primary signal drivers for upper-face and perinasal actions, respectively, and temple sensors as critical for cheek raiser detection. Significance. This study provides the first metrological validation of multi-channel capacitive sensing for AU-level recognition in eyewear. The results establish the modality as a robust, privacy-preserving, and illumination-independent alternative to optical methods for longitudinal physiological monitoring, with the current prototype serving as a wired research platform and full consumer-grade integration identified as a future engineering objective.
- 12 May 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (5) , 055011
Open AccessTurning glasses into sensors: capacitive facial expression recognition under frame geometry constraints
Objective. Wearable facial expression recognition requires sensing modalities that are unobtrusive, illumination-independent, and compatible with everyday eyewear form factors. Existing optical and electromyographic approaches are limited by line-of-sight requirements, skin contact, or restricted action unit (AU) coverage. This work investigates the feasibility of non-contact capacitive sensing for facial muscle activity monitoring within the strict geometric constraints of standard eyewear. Approach. We developed FERGlasses, integrating eight loading-mode capacitive channels via a custom flexible PCB and active shielding to detect skin-to-frame displacement. A validation study with 40 participants was conducted to elicit seven facial action coding system-defined AUs. Signal fidelity was assessed using independent Random Forest regressors and benchmarked against commercial optical-proximity (OCOsense) and computer-vision (Py-Feat) standards. Main results. The system demonstrated high agreement for upper-face activity, achieving median cosine similarities of 0.97 for the Outer Brow Raiser (AU02) and 0.87 for the Nose Wrinkler (AU09), while lower-face actions such as the Chin Raiser (AU17) yielded a median of 0.33, consistent with mechanical signal attenuation along the frame. Channel-ablation analysis quantified the specific anatomical contributions of each electrode group, identifying eyebrow and rhinion sensors as primary signal drivers for upper-face and perinasal actions, respectively, and temple sensors as critical for cheek raiser detection. Significance. This study provides the first metrological validation of multi-channel capacitive sensing for AU-level recognition in eyewear. The results establish the modality as a robust, privacy-preserving, and illumination-independent alternative to optical methods for longitudinal physiological monitoring, with the current prototype serving as a wired research platform and full consumer-grade integration identified as a future engineering objective.
- Open Access
- 3 November 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 396
Capacitive sensing for facial expression recognition and beyond: Materials, architectures, and wearable applications
- 3 November 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 396
Open AccessCapacitive sensing for facial expression recognition and beyond: Materials, architectures, and wearable applications