Fangqin Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fangqin Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Danlin Wen
Department of Ultrasound Sichuan Integrative Medicine Hospital Chengdu China
1 shared publication - Jia Xu
Department of Ultrasound Sichuan Integrative Medicine Hospital Chengdu China
1 shared publication - Jing Miao
Department of Ultrasound Sichuan Integrative Medicine Hospital Chengdu China
1 shared publication - Lang Qiao
Department of Ultrasound Sichuan Integrative Medicine Hospital Chengdu China
1 shared publication - Qiuyun Huang
School of Medical and Life Sciences Chengdu University of Traditional Chinese Medicine Chengdu China
1 shared publication - Yunhao Luo
Department of Ultrasound, West China Hospital of Sichuan University, China
1 shared publication
Latest Publications
- Open Access
- 29 October 2025
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (3) , 684-690
Preliminary Study on the Value of Contrast‐Enhanced Ultrasound in Enhancing Early Vascular Architecture for the Differential Diagnosis of Benign and Malignant Endometrial Lesions
Objective: To investigate the diagnostic value of contrast‐enhanced ultrasound (CEUS) in differentiating benign and malignant endometrial diseases by analyzing the early arterial vascular architecture on CEUS images. Methods: A prospective study was conducted at the Sichuan Integrative Medicine Hospital to enroll 70 suspected endometrial lesion patients with a mean age of 42.5 ± 8.2 years (range 27–69 years). The patients underwent conventional ultrasound and CEUS examinations, and pathological examinations were obtained through surgery or curettage. They were divided into the benign group and malignant group according to their pathological types. The CEUS image features were analyzed, and the sensitivity, specificity, positive predictive value, and other parameters were compared between the two groups by carefully observing the early enhancement images and comparing the differences in the vascular architecture, including the shape of the vessels, the number of vessels, and the vessel diameter. Results: There were significant differences in vascular shape, number, and diameter between the two groups. The difference in vascular morphology was highly statistically significant ( p < 0.001). The “vascular supply” was used for the diagnosis of malignant diseases of the endometrium with a high sensitivity of 95.8%, specificity of 77.5%, positive predictive value of 71.8%, and accuracy of 84.4%. When the maximum inner diameter exceeded 1.5 mm, the sensitivity and specificity for the diagnosis of malignant lesions were 95.8% and 82.5%, respectively, with a positive predictive value of 76.6% and an accuracy of 87.5%. When the average inner diameter exceeded 1.22 mm, the sensitivity for the diagnosis of malignant endometrial lesions was 87.5%, the specificity was 80%, and the accuracy was 82.8%. Conclusions: The utilization of CEUS vascular architecture holds significant clinical value in the diagnosis of both benign and malignant endometrial diseases, thereby warranting further comprehensive investigation.
- 29 October 2025
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (3) , 684-690
Open AccessPreliminary Study on the Value of Contrast‐Enhanced Ultrasound in Enhancing Early Vascular Architecture for the Differential Diagnosis of Benign and Malignant Endometrial Lesions
Objective: To investigate the diagnostic value of contrast‐enhanced ultrasound (CEUS) in differentiating benign and malignant endometrial diseases by analyzing the early arterial vascular architecture on CEUS images. Methods: A prospective study was conducted at the Sichuan Integrative Medicine Hospital to enroll 70 suspected endometrial lesion patients with a mean age of 42.5 ± 8.2 years (range 27–69 years). The patients underwent conventional ultrasound and CEUS examinations, and pathological examinations were obtained through surgery or curettage. They were divided into the benign group and malignant group according to their pathological types. The CEUS image features were analyzed, and the sensitivity, specificity, positive predictive value, and other parameters were compared between the two groups by carefully observing the early enhancement images and comparing the differences in the vascular architecture, including the shape of the vessels, the number of vessels, and the vessel diameter. Results: There were significant differences in vascular shape, number, and diameter between the two groups. The difference in vascular morphology was highly statistically significant ( p < 0.001). The “vascular supply” was used for the diagnosis of malignant diseases of the endometrium with a high sensitivity of 95.8%, specificity of 77.5%, positive predictive value of 71.8%, and accuracy of 84.4%. When the maximum inner diameter exceeded 1.5 mm, the sensitivity and specificity for the diagnosis of malignant lesions were 95.8% and 82.5%, respectively, with a positive predictive value of 76.6% and an accuracy of 87.5%. When the average inner diameter exceeded 1.22 mm, the sensitivity for the diagnosis of malignant endometrial lesions was 87.5%, the specificity was 80%, and the accuracy was 82.8%. Conclusions: The utilization of CEUS vascular architecture holds significant clinical value in the diagnosis of both benign and malignant endometrial diseases, thereby warranting further comprehensive investigation.