Mohammadsina Hassannia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammadsina Hassannia has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Gari D. Clifford
Emory University
2 shared publications - Reza Sameni
Emory University School of Medicine
2 shared publications - Agnar Martin Bjørnstad
Akershus University Hospital
1 shared publication Ali Bahrami Rad
Biomedical Informatics, Emory University, FL 4, Atlanta, Georgia, 30033, UNITED STATES
1 shared publication- Arian Ranjbar
Akershus University Hospital
1 shared publication - Audrey T Weigle
Emory University
1 shared publication
Latest Publications
- Open Access
- 27 July 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (7) , 075015
ECG-image-database: large-scale paired ECG images and time-series with real-world artifacts; a foundation for computerized ECG digitization and analysis
Objective. We present electrocardiogram (ECG)-Image-Database, comprising ECG image datasets paired with the underlying time-series signals. The database is designed to reflect real-world digitization challenges by incorporating diverse scanning, imaging, and physical artifacts commonly encountered in clinical and archival ECG records. It currently includes ECG images of records from Emory Healthcare (Atlanta, USA), the PTB-XL dataset from Physikalisch-Technische Bundesanstalt (Berlin, Germany), and Akershus University Hospital (Lørenskog, Norway). Approach. ECG images from Emory Healthcare and PTB-XL were generated using ECG-Image-Kit, an open-source toolkit that converts 12-lead ECG time series into realistic printout-style images. The toolkit introduces controlled digital distortions, including noise, wrinkles, stains, and perspective changes. A total of 1977 ECG records (977 PTB-XL and 1000 Emory Healthcare) were processed to create high-fidelity ECG printouts. These images were further subjected to physical degradation—such as soaking, staining, and mold exposure—before being scanned or photographed under varying lighting and capture conditions. In addition, we captured mobile photographs of the original ECG images displayed on computer monitors. This process resulted in 35 595 images. Independently, ECG images from Akershus University Hospital were captured from thermal-paper ECG printouts from 266 patients acquired during routine clinical care. Each printout underwent natural handling degradation and was repeatedly scanned and photographed, yielding 1596 images. Main results. ECG-Image-Database contains 37 191 images derived from 2243 ECG records across three countries. The dataset spans clean scans, noisy photographs, and severe physical deterioration, and includes heterogeneous ECG layouts and acquisition conditions. Each record is linked to its corresponding digital ECG time series, enabling supervised training and benchmarking of digitization and classification methods. Subsets of this resource were used in the PhysioNet Challenge 2024 and a subsequent 2025–2026 Kaggle challenge on ECG image digitization and classification. The database is structured for scalability and future expansion. Significance. By providing paired ECG images and signals across diverse real-world artifact conditions, ECG-Image-Database supports robust development of methods for recovering ECG time series from images and for direct image-based interpretation, helping preserve diagnostic value from non-digital ECG archives.
- 27 July 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (7) , 075015
Open AccessECG-image-database: large-scale paired ECG images and time-series with real-world artifacts; a foundation for computerized ECG digitization and analysis
Objective. We present electrocardiogram (ECG)-Image-Database, comprising ECG image datasets paired with the underlying time-series signals. The database is designed to reflect real-world digitization challenges by incorporating diverse scanning, imaging, and physical artifacts commonly encountered in clinical and archival ECG records. It currently includes ECG images of records from Emory Healthcare (Atlanta, USA), the PTB-XL dataset from Physikalisch-Technische Bundesanstalt (Berlin, Germany), and Akershus University Hospital (Lørenskog, Norway). Approach. ECG images from Emory Healthcare and PTB-XL were generated using ECG-Image-Kit, an open-source toolkit that converts 12-lead ECG time series into realistic printout-style images. The toolkit introduces controlled digital distortions, including noise, wrinkles, stains, and perspective changes. A total of 1977 ECG records (977 PTB-XL and 1000 Emory Healthcare) were processed to create high-fidelity ECG printouts. These images were further subjected to physical degradation—such as soaking, staining, and mold exposure—before being scanned or photographed under varying lighting and capture conditions. In addition, we captured mobile photographs of the original ECG images displayed on computer monitors. This process resulted in 35 595 images. Independently, ECG images from Akershus University Hospital were captured from thermal-paper ECG printouts from 266 patients acquired during routine clinical care. Each printout underwent natural handling degradation and was repeatedly scanned and photographed, yielding 1596 images. Main results. ECG-Image-Database contains 37 191 images derived from 2243 ECG records across three countries. The dataset spans clean scans, noisy photographs, and severe physical deterioration, and includes heterogeneous ECG layouts and acquisition conditions. Each record is linked to its corresponding digital ECG time series, enabling supervised training and benchmarking of digitization and classification methods. Subsets of this resource were used in the PhysioNet Challenge 2024 and a subsequent 2025–2026 Kaggle challenge on ECG image digitization and classification. The database is structured for scalability and future expansion. Significance. By providing paired ECG images and signals across diverse real-world artifact conditions, ECG-Image-Database supports robust development of methods for recovering ECG time series from images and for direct image-based interpretation, helping preserve diagnostic value from non-digital ECG archives.
- Open Access
- 10 November 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (11) , 115005
Estimating blood pressure from the electrocardiogram: findings of a large-scale negative results study
Objective. Electrocardiography and blood pressure (BP) measurement are two widely used tools for diagnosis and monitoring cardiovascular diseases. While the electrocardiogram (ECG) and BP have been considered complementary modalities, there are also systematic relationships between them. Therefore, advancements in portable and wearable ECG devices, along with promising results in cuff-less BP measurement using a combination of ECG and other bio-signals have led researchers to hypothesize the possibility of estimating BP and classifying BP categories (e.g. normal vs. hypertensive) using only ECG. However, the literature is divided on this topic: some studies support this hypothesis, while others reject it. Approach. In this study, regression and classification machine learning (ML) models were developed to explore the feasibility of estimating BP and predicting BP categories (normal vs. hypertensive) from 30 s ECGs using an extensive dataset from AliveCor Inc. which includes 124 427 records from 7412 subjects. The ECG and BP recordings were asynchronous with variable counts and time lags. Therefore, a 3.5 min time window before and after each ECG recording was used to calculate the mean BP measurement. Sex-aware ML models were trained using a comprehensive feature vector comprising 280 features: 128 explainable ECG features developed by the research team and 150 ECG features extracted by the Black Swan team, one of the top-performing teams in the PhysioNet Challenge 2017. Additionally, the average time gap between each ECG and the corresponding BP measurement, along with the subject’s age, were included as two supplementary features. Main results. Our best regression ML models achieved a mean absolute error of 12.59 mmHg for estimating systolic BP and 7.43 mmHg for diastolic BP, with correlation coefficients of 0.35 and 0.38 between the predicted and actual values, respectively. The best BP normal-hypertensive classification model achieved an area under the receiver operating characteristic curve of 0.655. Significance. Using a large dataset of ECG and BP recordings, this study found that ML models did not achieve acceptable performance in predicting BP values or classifying BP categories, indicating that BP cannot be reliably estimated from the ECG.
- 10 November 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (11) , 115005
Open AccessEstimating blood pressure from the electrocardiogram: findings of a large-scale negative results study
Objective. Electrocardiography and blood pressure (BP) measurement are two widely used tools for diagnosis and monitoring cardiovascular diseases. While the electrocardiogram (ECG) and BP have been considered complementary modalities, there are also systematic relationships between them. Therefore, advancements in portable and wearable ECG devices, along with promising results in cuff-less BP measurement using a combination of ECG and other bio-signals have led researchers to hypothesize the possibility of estimating BP and classifying BP categories (e.g. normal vs. hypertensive) using only ECG. However, the literature is divided on this topic: some studies support this hypothesis, while others reject it. Approach. In this study, regression and classification machine learning (ML) models were developed to explore the feasibility of estimating BP and predicting BP categories (normal vs. hypertensive) from 30 s ECGs using an extensive dataset from AliveCor Inc. which includes 124 427 records from 7412 subjects. The ECG and BP recordings were asynchronous with variable counts and time lags. Therefore, a 3.5 min time window before and after each ECG recording was used to calculate the mean BP measurement. Sex-aware ML models were trained using a comprehensive feature vector comprising 280 features: 128 explainable ECG features developed by the research team and 150 ECG features extracted by the Black Swan team, one of the top-performing teams in the PhysioNet Challenge 2017. Additionally, the average time gap between each ECG and the corresponding BP measurement, along with the subject’s age, were included as two supplementary features. Main results. Our best regression ML models achieved a mean absolute error of 12.59 mmHg for estimating systolic BP and 7.43 mmHg for diastolic BP, with correlation coefficients of 0.35 and 0.38 between the predicted and actual values, respectively. The best BP normal-hypertensive classification model achieved an area under the receiver operating characteristic curve of 0.655. Significance. Using a large dataset of ECG and BP recordings, this study found that ML models did not achieve acceptable performance in predicting BP values or classifying BP categories, indicating that BP cannot be reliably estimated from the ECG.