Shihao Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shihao Chen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Beiyu Wang
Department of Orthopedic Surgery West China Hospital, Sichuan University Chengdu China
3 shared publications Kangkang Huang
Department of Orthopedic Surgery West China Hospital, Sichuan University Chengdu China
3 shared publicationsYi Deng
Department of Orthopedic Surgery West China Hospital, Sichuan University Chengdu China
3 shared publications- Hao Liu
Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, No. 37 Guo Xue Rd, Chengdu 610041, China
2 shared publications Minghe Yao
Department of Orthopedic Surgery West China Hospital, Sichuan University Chengdu China
2 shared publicationsTingkui Wu
Department of Orthopedic Surgery West China Hospital, Sichuan University Chengdu China
2 shared publications
Latest Publications
- Open Access
- 22 November 2026
- Published by Wiley in Orthopaedic Surgery
Four‐Screw Versus Two‐Screw Zero‐Profile Implants: Effects on Overloaded Vertebral Body Following Anterior Cervical Discectomy and Fusion
Objective: Although zero‐profile implants with different screw configurations are increasingly used in anterior cervical discectomy and fusion (ACDF), whether four‐screw and two‐screw designs differentially affect the overloaded vertebral body (OVB) remains unknown. This study aimed to compare the effects of four‐screw and two‐screw zero‐profile implants on radiological outcomes of the OVB and clinical outcomes after two‐level ACDF, and to provide a reference for further investigation and prevention of OVB deformation. Methods: This retrospective study analyzed 209 patients who underwent two‐level ACDF between April 2012 and May 2023. Radiographic parameters included anterior vertebral height (AH), posterior vertebral height (PH), cross‐sectional area (CSA), wedge angle (WA), wedge ratio (WR), cervical lordosis (CL), and surgical segment angle (SSA). Clinical outcomes were evaluated using the modified Japanese Orthopedic Association (mJOA) score, neck disability index (NDI) score, and visual analog scale (VAS) score for neck and arm pain. Surgical safety was evaluated based on the incidence of complications during the follow‐up period. Results: The deformities of OVB in both groups primarily presented as the reduction in AH and WR. The four‐screw group exhibited less deformation compared to the two‐screw group. At 3 months, 6 months, 12 months, and the final follow‐up, the AH and WR of OVB in the two‐screw group were significantly lower than those in the four‐screw group ( p < 0.05). Similarly, at 6 months, 12 months, and the final follow‐up, the CSA of OVB was significantly lower, and the WA showed a significantly greater magnitude of kyphotic change in the two‐screw group compared to the four‐screw group ( p < 0.05). By 12 months postoperatively, OVB in the two‐screw group was in mild deformation. Compared with the four‐screw group, the two‐screw group demonstrated a greater loss of cervical lordosis at the final follow‐up ( p < 0.05). Although both groups showed significant clinical improvement from the preoperative baseline, a statistically significant difference in VAS scores of the neck was observed between the two groups at the final follow‐up ( p < 0.05). Conclusions: Our study showed that comparable clinical outcomes can be achieved in two‐level ACDF using either four‐screw or two‐screw zero‐profile implants. However, the four‐screw implant showed superior performance in preventing and delaying postoperative deformation of OVB compared to the two‐screw implant, which is crucial for sustaining cervical sagittal balance and improving long‐term clinical outcomes.
- 22 November 2026
- Published by Wiley in Orthopaedic Surgery
Open AccessFour‐Screw Versus Two‐Screw Zero‐Profile Implants: Effects on Overloaded Vertebral Body Following Anterior Cervical Discectomy and Fusion
Objective: Although zero‐profile implants with different screw configurations are increasingly used in anterior cervical discectomy and fusion (ACDF), whether four‐screw and two‐screw designs differentially affect the overloaded vertebral body (OVB) remains unknown. This study aimed to compare the effects of four‐screw and two‐screw zero‐profile implants on radiological outcomes of the OVB and clinical outcomes after two‐level ACDF, and to provide a reference for further investigation and prevention of OVB deformation. Methods: This retrospective study analyzed 209 patients who underwent two‐level ACDF between April 2012 and May 2023. Radiographic parameters included anterior vertebral height (AH), posterior vertebral height (PH), cross‐sectional area (CSA), wedge angle (WA), wedge ratio (WR), cervical lordosis (CL), and surgical segment angle (SSA). Clinical outcomes were evaluated using the modified Japanese Orthopedic Association (mJOA) score, neck disability index (NDI) score, and visual analog scale (VAS) score for neck and arm pain. Surgical safety was evaluated based on the incidence of complications during the follow‐up period. Results: The deformities of OVB in both groups primarily presented as the reduction in AH and WR. The four‐screw group exhibited less deformation compared to the two‐screw group. At 3 months, 6 months, 12 months, and the final follow‐up, the AH and WR of OVB in the two‐screw group were significantly lower than those in the four‐screw group ( p < 0.05). Similarly, at 6 months, 12 months, and the final follow‐up, the CSA of OVB was significantly lower, and the WA showed a significantly greater magnitude of kyphotic change in the two‐screw group compared to the four‐screw group ( p < 0.05). By 12 months postoperatively, OVB in the two‐screw group was in mild deformation. Compared with the four‐screw group, the two‐screw group demonstrated a greater loss of cervical lordosis at the final follow‐up ( p < 0.05). Although both groups showed significant clinical improvement from the preoperative baseline, a statistically significant difference in VAS scores of the neck was observed between the two groups at the final follow‐up ( p < 0.05). Conclusions: Our study showed that comparable clinical outcomes can be achieved in two‐level ACDF using either four‐screw or two‐screw zero‐profile implants. However, the four‐screw implant showed superior performance in preventing and delaying postoperative deformation of OVB compared to the two‐screw implant, which is crucial for sustaining cervical sagittal balance and improving long‐term clinical outcomes.
- Open Access
- 24 September 2026
- Published by Wiley in Orthopaedic Surgery
- Vol. 18 (11) , 2428-2439
Effect of Keeping Caspar Retractor During Prestige LP Cervical Disc Implantation on Intra‐ and Postoperative Outcomes
Objectives: Implantation of the Prestige LP prosthesis requires substantial endplate modification and insertion forces, yet the manufacturer's guide recommends relaxing or completely removing the Caspar retractor before implantation, which we observed to cause vertebral instability during endplate preparation and prosthesis insertion. This study aimed to evaluate the effect of retaining the Caspar retractor during Prestige LP cervical disc implantation. Methods: A total of 55 patients who underwent cervical disc arthroplasty (CDA) between January and December 2025 were retrospectively reviewed. The retractor group maintained the retractor during endplate preparation and prosthesis implantation, while the no‐retractor group removed it after discectomy. Clinical outcomes and radiographic parameters were assessed preoperatively, intraoperatively, and at 1 week, 3 months, and 6 months postoperatively. Statistical analyses were performed using two‐way repeated‐measures ANOVA, paired and independent t ‐tests, Mann–Whitney U test, and Chi‐square test. Results: Clinical outcomes were similar in both groups. The retractor group demonstrated superior intraoperative stability with reduced functional spinal unit (FSU) Cobb angle fluctuations ( p = 0.001), fewer fluoroscopy exposures ( p = 0.044), and shorter prosthesis implantation times ( p = 0.017). The retractor group received significantly larger prostheses ( p < 0.001). Postoperatively, the retractor group exhibited greater FSU height, disc height, and larger interfacet distance (all p < 0.005) but these differences diminished by 6 months. The retractor group also showed smaller bone–implant interface gap ( p = 0.003) at 1 week, and more segmental range of motion ( p < 0.008) and FSU height loss ( p = 0.002) at 6 months. Subsidence and heterotopic ossification rates were comparable between groups. Conclusion: During Prestige LP implantation in CDA, retaining the Caspar retractor enhanced intraoperative stability, improved prosthesis placement accuracy, and reduced fluoroscopy use, achieving comparable clinical outcomes. While associated with greater FSU height loss at 6 months, it did not increase complications, supporting its viability as a standard technical modification for Prestige LP implantation.
- 24 September 2026
- Published by Wiley in Orthopaedic Surgery
- Vol. 18 (11) , 2428-2439
Open AccessEffect of Keeping Caspar Retractor During Prestige LP Cervical Disc Implantation on Intra‐ and Postoperative Outcomes
Objectives: Implantation of the Prestige LP prosthesis requires substantial endplate modification and insertion forces, yet the manufacturer's guide recommends relaxing or completely removing the Caspar retractor before implantation, which we observed to cause vertebral instability during endplate preparation and prosthesis insertion. This study aimed to evaluate the effect of retaining the Caspar retractor during Prestige LP cervical disc implantation. Methods: A total of 55 patients who underwent cervical disc arthroplasty (CDA) between January and December 2025 were retrospectively reviewed. The retractor group maintained the retractor during endplate preparation and prosthesis implantation, while the no‐retractor group removed it after discectomy. Clinical outcomes and radiographic parameters were assessed preoperatively, intraoperatively, and at 1 week, 3 months, and 6 months postoperatively. Statistical analyses were performed using two‐way repeated‐measures ANOVA, paired and independent t ‐tests, Mann–Whitney U test, and Chi‐square test. Results: Clinical outcomes were similar in both groups. The retractor group demonstrated superior intraoperative stability with reduced functional spinal unit (FSU) Cobb angle fluctuations ( p = 0.001), fewer fluoroscopy exposures ( p = 0.044), and shorter prosthesis implantation times ( p = 0.017). The retractor group received significantly larger prostheses ( p < 0.001). Postoperatively, the retractor group exhibited greater FSU height, disc height, and larger interfacet distance (all p < 0.005) but these differences diminished by 6 months. The retractor group also showed smaller bone–implant interface gap ( p = 0.003) at 1 week, and more segmental range of motion ( p < 0.008) and FSU height loss ( p = 0.002) at 6 months. Subsidence and heterotopic ossification rates were comparable between groups. Conclusion: During Prestige LP implantation in CDA, retaining the Caspar retractor enhanced intraoperative stability, improved prosthesis placement accuracy, and reduced fluoroscopy use, achieving comparable clinical outcomes. While associated with greater FSU height loss at 6 months, it did not increase complications, supporting its viability as a standard technical modification for Prestige LP implantation.
- Open Access
- 31 October 2025
- Published by Wiley in Orthopaedic Surgery
- Vol. 17 (12) , 3432-3439
To What Extent Do Different Criteria Influence 3‐Month Fusion Evaluation in Anterior Cervical Arthrodesis Trials?
Objectives: Multiple imaging criteria are available for assessing fusion following anterior cervical discectomy and fusion (ACDF). In clinical trials, the 3‐month postoperative follow‐up serves as a critical timepoint for evaluating the efficacy of interventions on accelerating the fusion process. This study aims to determine how applying different fusion criteria influences the conclusions of a comparative analysis. Methods: Patients aged 18 or older who underwent ACDF with allograft or beta‐tricalcium phosphate artificial bone between C3 and C7 were reviewed from 1 April 2023 to 30 September 2023. Fusion rates between the two grafts at three‐month follow‐up were compared under different criteria. Fusion status was judged by CT or dynamic radiographs, or their combinations. Cut‐offs of dynamic indicators included angle changes of 4°, 3°, and 2°, and interspinous motion of 3, 2, and 1 mm. Criteria were applied singly, combined in pairs, or combined in groups of three, leading to a total of 31 criteria. Student's t ‐test and Chi‐squared test were employed, and Cohen's kappa coefficient and phi coefficient were calculated. Results: Ninety‐eight segments were included. Twenty‐five criteria yielded higher fusion rates for artificial bone, with 7 out of 25 reaching statistical significance ( p < 0.05). The remaining six criteria led to a reversed result, but none reached significance ( p > 0.05). The agreement and correlation between CT and dynamic criteria were poor (kappa and phi < 0.200). In contrast, the agreement and correlation between two dynamic indicators were better, and even being close to moderate (kappa = 0.398, phi = 0.398) between 3° and 2 mm. Conclusion: Changes in fusion criteria affected result significance but did not produce conflicting conclusions. There was a significant disagreement between the results under CT and dynamic radiographs criteria. Thresholds of 3° or 2 mm can be optimal choices for dynamic criteria.
- 31 October 2025
- Published by Wiley in Orthopaedic Surgery
- Vol. 17 (12) , 3432-3439
Open AccessTo What Extent Do Different Criteria Influence 3‐Month Fusion Evaluation in Anterior Cervical Arthrodesis Trials?
Objectives: Multiple imaging criteria are available for assessing fusion following anterior cervical discectomy and fusion (ACDF). In clinical trials, the 3‐month postoperative follow‐up serves as a critical timepoint for evaluating the efficacy of interventions on accelerating the fusion process. This study aims to determine how applying different fusion criteria influences the conclusions of a comparative analysis. Methods: Patients aged 18 or older who underwent ACDF with allograft or beta‐tricalcium phosphate artificial bone between C3 and C7 were reviewed from 1 April 2023 to 30 September 2023. Fusion rates between the two grafts at three‐month follow‐up were compared under different criteria. Fusion status was judged by CT or dynamic radiographs, or their combinations. Cut‐offs of dynamic indicators included angle changes of 4°, 3°, and 2°, and interspinous motion of 3, 2, and 1 mm. Criteria were applied singly, combined in pairs, or combined in groups of three, leading to a total of 31 criteria. Student's t ‐test and Chi‐squared test were employed, and Cohen's kappa coefficient and phi coefficient were calculated. Results: Ninety‐eight segments were included. Twenty‐five criteria yielded higher fusion rates for artificial bone, with 7 out of 25 reaching statistical significance ( p < 0.05). The remaining six criteria led to a reversed result, but none reached significance ( p > 0.05). The agreement and correlation between CT and dynamic criteria were poor (kappa and phi < 0.200). In contrast, the agreement and correlation between two dynamic indicators were better, and even being close to moderate (kappa = 0.398, phi = 0.398) between 3° and 2 mm. Conclusion: Changes in fusion criteria affected result significance but did not produce conflicting conclusions. There was a significant disagreement between the results under CT and dynamic radiographs criteria. Thresholds of 3° or 2 mm can be optimal choices for dynamic criteria.