JZJiawei Zhang

Jiawei Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiawei Zhang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantitative Assessment of Strabismus Using Cloud AI Computing: Validation Study

    by Junxian He, Jiawei Zhang, Zheng Wang, Shrinivas Pundlik, Rui Liu, Gang Luo

    Background: Strabismus measurement is essential in vision assessment and screening. It typically requires skilled clinicians or specialized equipment. Photographic strabismus measurement methods have value in terms of accessibility and convenience of use. Objective: This study aimed to evaluate Eyeturn Cloud, a cloud-based artificial intelligence (AI) system for measuring strabismus angles based on eye images captured with smartphone cameras under cover test conditions. Methods: The Eyeturn Cloud web app uses AI models to recognize eyes, eye lid, and iris, and then to segment iris precisely. It then computes strabismus based on ellipse fitting of the iris boundary and corneal reflection. The system was evaluated in patients (without glasses) with manifest strabismus and control participants. Clinicians measured eye deviations using the prism alternate cover test and also captured pictures of their eyes under alternate cover and unilateral cover conditions. The pictures were processed by Eyeturn Cloud. Results: In total, 79 (mean age 11.9, SD 6.3 years; esotropia: n=15, exotropia: n=55, orthotropia: n=9) participants were enrolled; of which, data were available for 71 participants (8/79, 10.1% processing failure). The range of prism alternate cover test strabismus magnitude was from 78 base in to 78 base out prism diopters (PDs). A strong correlation was found between Eyeturn Cloud and clinical measurements (R2=0.95; slope=0.91; P<.001). Bland-Altman analysis revealed that 95% limits of agreement between the 2 measurements were –20.2 to 14.6 PD. A repeatability test with 15 participants (4 photos each) found a 1.53 PD SD. Conclusions: The cloud AI web app can compute strabismus angles reliably under alternate and unilateral cover conditions in clinical settings, and its potential for use in telehealth settings needs further evaluation.


  • Open Access

    Quantitative Assessment of Strabismus Using Cloud AI Computing: Validation Study (Preprint)

    by Junxian He, Jiawei Zhang, Zheng Wang, Shrinivas Pundlik, Rui Liu, Gang Luo

    BACKGROUND Strabismus measurement is essential in vision assessment and screening. It typically requires skilled clinicians or specialized equipment. Photographic strabismus measurement methods have value in terms of accessibility and convenience of use. OBJECTIVE This study aimed to evaluate Eyeturn Cloud, a cloud-based artificial intelligence (AI) system for measuring strabismus angles based on eye images captured with smartphone cameras under cover test conditions. METHODS The Eyeturn Cloud web app uses AI models to recognize eyes, eye lid, and iris, and then to segment iris precisely. It then computes strabismus based on ellipse fitting of the iris boundary and corneal reflection. The system was evaluated in patients (without glasses) with manifest strabismus and control participants. Clinicians measured eye deviations using the prism alternate cover test and also captured pictures of their eyes under alternate cover and unilateral cover conditions. The pictures were processed by Eyeturn Cloud. RESULTS In total, 79 (mean age 11.9, SD 6.3 years; esotropia: n=15, exotropia: n=55, orthotropia: n=9) participants were enrolled; of which, data were available for 71 participants (8/79, 10.1% processing failure). The range of prism alternate cover test strabismus magnitude was from 78 base in to 78 base out prism diopters (PDs). A strong correlation was found between Eyeturn Cloud and clinical measurements (R2=0.95; slope=0.91; P<.001). Bland-Altman analysis revealed that 95% limits of agreement between the 2 measurements were –20.2 to 14.6 PD. A repeatability test with 15 participants (4 photos each) found a 1.53 PD SD. CONCLUSIONS The cloud AI web app can compute strabismus angles reliably under alternate and unilateral cover conditions in clinical settings, and its potential for use in telehealth settings needs further evaluation.