Jiawei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jiawei Zhang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Gang Luo
Schepens Eye Research Institute of Mass Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
2 shared publications - Junxian He
School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, China
2 shared publications - Rui Liu
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
2 shared publications - Shrinivas Pundlik
Schepens Eye Research Institute of Mass Eye & Ear, Harvard Medical School, Boston, MA, USA
2 shared publications - Zheng Wang
School of Medicine, Jiaxing University, Jiaxing, China
2 shared publications
Latest Publications
- Open Access
- 4 November 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 9, e79280
Quantitative Assessment of Strabismus Using Cloud AI Computing: Validation Study
Background: Strabismus measurement is essential in vision assessment and screening. It typically requires skilled clinicians or specialized equipment. Photographic strabismus measurement methods have value in terms of accessibility and convenience of use. Objective: This study aimed to evaluate Eyeturn Cloud, a cloud-based artificial intelligence (AI) system for measuring strabismus angles based on eye images captured with smartphone cameras under cover test conditions. Methods: The Eyeturn Cloud web app uses AI models to recognize eyes, eye lid, and iris, and then to segment iris precisely. It then computes strabismus based on ellipse fitting of the iris boundary and corneal reflection. The system was evaluated in patients (without glasses) with manifest strabismus and control participants. Clinicians measured eye deviations using the prism alternate cover test and also captured pictures of their eyes under alternate cover and unilateral cover conditions. The pictures were processed by Eyeturn Cloud. Results: In total, 79 (mean age 11.9, SD 6.3 years; esotropia: n=15, exotropia: n=55, orthotropia: n=9) participants were enrolled; of which, data were available for 71 participants (8/79, 10.1% processing failure). The range of prism alternate cover test strabismus magnitude was from 78 base in to 78 base out prism diopters (PDs). A strong correlation was found between Eyeturn Cloud and clinical measurements (R2=0.95; slope=0.91; P<.001). Bland-Altman analysis revealed that 95% limits of agreement between the 2 measurements were –20.2 to 14.6 PD. A repeatability test with 15 participants (4 photos each) found a 1.53 PD SD. Conclusions: The cloud AI web app can compute strabismus angles reliably under alternate and unilateral cover conditions in clinical settings, and its potential for use in telehealth settings needs further evaluation.
- 4 November 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 9, e79280
Open AccessQuantitative Assessment of Strabismus Using Cloud AI Computing: Validation Study
Background: Strabismus measurement is essential in vision assessment and screening. It typically requires skilled clinicians or specialized equipment. Photographic strabismus measurement methods have value in terms of accessibility and convenience of use. Objective: This study aimed to evaluate Eyeturn Cloud, a cloud-based artificial intelligence (AI) system for measuring strabismus angles based on eye images captured with smartphone cameras under cover test conditions. Methods: The Eyeturn Cloud web app uses AI models to recognize eyes, eye lid, and iris, and then to segment iris precisely. It then computes strabismus based on ellipse fitting of the iris boundary and corneal reflection. The system was evaluated in patients (without glasses) with manifest strabismus and control participants. Clinicians measured eye deviations using the prism alternate cover test and also captured pictures of their eyes under alternate cover and unilateral cover conditions. The pictures were processed by Eyeturn Cloud. Results: In total, 79 (mean age 11.9, SD 6.3 years; esotropia: n=15, exotropia: n=55, orthotropia: n=9) participants were enrolled; of which, data were available for 71 participants (8/79, 10.1% processing failure). The range of prism alternate cover test strabismus magnitude was from 78 base in to 78 base out prism diopters (PDs). A strong correlation was found between Eyeturn Cloud and clinical measurements (R2=0.95; slope=0.91; P<.001). Bland-Altman analysis revealed that 95% limits of agreement between the 2 measurements were –20.2 to 14.6 PD. A repeatability test with 15 participants (4 photos each) found a 1.53 PD SD. Conclusions: The cloud AI web app can compute strabismus angles reliably under alternate and unilateral cover conditions in clinical settings, and its potential for use in telehealth settings needs further evaluation.
- Open Access
- 19 June 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Quantitative Assessment of Strabismus Using Cloud AI Computing: Validation Study (Preprint)
BACKGROUND Strabismus measurement is essential in vision assessment and screening. It typically requires skilled clinicians or specialized equipment. Photographic strabismus measurement methods have value in terms of accessibility and convenience of use. OBJECTIVE This study aimed to evaluate Eyeturn Cloud, a cloud-based artificial intelligence (AI) system for measuring strabismus angles based on eye images captured with smartphone cameras under cover test conditions. METHODS The Eyeturn Cloud web app uses AI models to recognize eyes, eye lid, and iris, and then to segment iris precisely. It then computes strabismus based on ellipse fitting of the iris boundary and corneal reflection. The system was evaluated in patients (without glasses) with manifest strabismus and control participants. Clinicians measured eye deviations using the prism alternate cover test and also captured pictures of their eyes under alternate cover and unilateral cover conditions. The pictures were processed by Eyeturn Cloud. RESULTS In total, 79 (mean age 11.9, SD 6.3 years; esotropia: n=15, exotropia: n=55, orthotropia: n=9) participants were enrolled; of which, data were available for 71 participants (8/79, 10.1% processing failure). The range of prism alternate cover test strabismus magnitude was from 78 base in to 78 base out prism diopters (PDs). A strong correlation was found between Eyeturn Cloud and clinical measurements (R2=0.95; slope=0.91; P<.001). Bland-Altman analysis revealed that 95% limits of agreement between the 2 measurements were –20.2 to 14.6 PD. A repeatability test with 15 participants (4 photos each) found a 1.53 PD SD. CONCLUSIONS The cloud AI web app can compute strabismus angles reliably under alternate and unilateral cover conditions in clinical settings, and its potential for use in telehealth settings needs further evaluation.
- 19 June 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessQuantitative Assessment of Strabismus Using Cloud AI Computing: Validation Study (Preprint)
BACKGROUND Strabismus measurement is essential in vision assessment and screening. It typically requires skilled clinicians or specialized equipment. Photographic strabismus measurement methods have value in terms of accessibility and convenience of use. OBJECTIVE This study aimed to evaluate Eyeturn Cloud, a cloud-based artificial intelligence (AI) system for measuring strabismus angles based on eye images captured with smartphone cameras under cover test conditions. METHODS The Eyeturn Cloud web app uses AI models to recognize eyes, eye lid, and iris, and then to segment iris precisely. It then computes strabismus based on ellipse fitting of the iris boundary and corneal reflection. The system was evaluated in patients (without glasses) with manifest strabismus and control participants. Clinicians measured eye deviations using the prism alternate cover test and also captured pictures of their eyes under alternate cover and unilateral cover conditions. The pictures were processed by Eyeturn Cloud. RESULTS In total, 79 (mean age 11.9, SD 6.3 years; esotropia: n=15, exotropia: n=55, orthotropia: n=9) participants were enrolled; of which, data were available for 71 participants (8/79, 10.1% processing failure). The range of prism alternate cover test strabismus magnitude was from 78 base in to 78 base out prism diopters (PDs). A strong correlation was found between Eyeturn Cloud and clinical measurements (R2=0.95; slope=0.91; P<.001). Bland-Altman analysis revealed that 95% limits of agreement between the 2 measurements were –20.2 to 14.6 PD. A repeatability test with 15 participants (4 photos each) found a 1.53 PD SD. CONCLUSIONS The cloud AI web app can compute strabismus angles reliably under alternate and unilateral cover conditions in clinical settings, and its potential for use in telehealth settings needs further evaluation.