Eduardo Cortina Gil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eduardo Cortina Gil has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Alexis Warnier
IBA Dosimetry
1 shared publication - Andrea Giammanco
Université catholique de Louvain
1 shared publication - Anna Cimmino
ELI Beamlines facility, The Extreme Light Infrastructure ERIC, 252 41 Dolní Břežany, Czech Republic
1 shared publication - Ari J. Sloss
Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, MD 20742, USA
1 shared publication - Donya Ahmadi
Vrije Universiteit Brussel
1 shared publication - Ela Rockafellow
Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, MD 20742, USA
1 shared publication
Latest Publications
- Open Access
- 8 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9946
RPC Telescope Tests for Muon Detection at Laser-Plasma Accelerators
We report on a feasibility study conducted at the ELBA station at the ELI Beamlines facility to investigate the possible production of muons from high-energy electron beams generated by extended laser–plasma interactions in optically generated plasma waveguides. Our team operated a portable, autonomous, and compact telescope based on Resistive Plate Chamber (RPC) detectors, positioned to detect high-penetration charged particles originating from the beam dump. The campaign demonstrated the stable operation of the RPC telescope in the challenging radiation and electromagnetic environment of ELBA. The collected datasets, though statistically limited and acquired during parasitic operation of the accelerator, allow detailed characterization of the background and validated the detectors’ stability and tracking performance. These results confirm the feasibility of the approach and provide the foundation for a dedicated future run under optimized beam conditions, where muon detection sensitivity will be substantially improved.
- 8 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9946
Open AccessRPC Telescope Tests for Muon Detection at Laser-Plasma Accelerators
We report on a feasibility study conducted at the ELBA station at the ELI Beamlines facility to investigate the possible production of muons from high-energy electron beams generated by extended laser–plasma interactions in optically generated plasma waveguides. Our team operated a portable, autonomous, and compact telescope based on Resistive Plate Chamber (RPC) detectors, positioned to detect high-penetration charged particles originating from the beam dump. The campaign demonstrated the stable operation of the RPC telescope in the challenging radiation and electromagnetic environment of ELBA. The collected datasets, though statistically limited and acquired during parasitic operation of the accelerator, allow detailed characterization of the background and validated the detectors’ stability and tracking performance. These results confirm the feasibility of the approach and provide the foundation for a dedicated future run under optimized beam conditions, where muon detection sensitivity will be substantially improved.
- Open Access
- 6 November 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 338, 09008
Feasibility study of a 2D Amorphous Silicon-based Detector for Proton Therapy
New particle therapy modalities, including ultra-high dose rate (UHDR) proton therapy, present various challenges for particle detectors used in patient-specific quality assurance (PSQA). Amorphous Silicon (a-Si) Flat Panel (FP) detectors are a powerful tool used to create a 2D image of an administered dose map. They are known for high radiation hardness and image resolution. To investigate and characterize the behavior of a-Si pixels under particle therapy irradiation, specifically proton irradiation, a 2.4 x 2.4 mm pixel array of a-Si pixels, photodiodes coupled with thin-film-transistors (TFTs), was acquired and tested. Before irradiation, electronic probing was performed to generate the I-V curves and to qualify the stability of the pixel current for different bias and gate voltages to understand the proper voltage regime for optimal pixel functionality. In addition, proton irradiation was performed using pencil beam scanning (PBS) in a medical facility for charge linearity verification through direct detection. The test was done in conjunction with an IBA Razor TM Detector to compare each detector’s performance. Finally, irradiation with a high-power green laser was performed to examine the performance of the individual components of the pixels under high-intensity irradiation.
- 6 November 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 338, 09008
Open AccessFeasibility study of a 2D Amorphous Silicon-based Detector for Proton Therapy
New particle therapy modalities, including ultra-high dose rate (UHDR) proton therapy, present various challenges for particle detectors used in patient-specific quality assurance (PSQA). Amorphous Silicon (a-Si) Flat Panel (FP) detectors are a powerful tool used to create a 2D image of an administered dose map. They are known for high radiation hardness and image resolution. To investigate and characterize the behavior of a-Si pixels under particle therapy irradiation, specifically proton irradiation, a 2.4 x 2.4 mm pixel array of a-Si pixels, photodiodes coupled with thin-film-transistors (TFTs), was acquired and tested. Before irradiation, electronic probing was performed to generate the I-V curves and to qualify the stability of the pixel current for different bias and gate voltages to understand the proper voltage regime for optimal pixel functionality. In addition, proton irradiation was performed using pencil beam scanning (PBS) in a medical facility for charge linearity verification through direct detection. The test was done in conjunction with an IBA Razor TM Detector to compare each detector’s performance. Finally, irradiation with a high-power green laser was performed to examine the performance of the individual components of the pixels under high-intensity irradiation.