Valentino Festa
Research Subjects
Valentino Festa has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Rosa Francesca De Masi
Università degli Studi del Sannio
4 shared publications Antonio Gigante
Universit degli studi del Sannio,Department of Engineering,Benevento,Italy
3 shared publications- Silvia Ruggiero
Università degli Studi del Sannio
3 shared publications - Giuseppe Peter Vanoli
Dipartimento di Medicina e Scienze della Salute DIMES, Università degli Studi del Molise
2 shared publications Alessando Russo
Universit degli studi del Sannio,Department of Engineering,Benevento,Italy
1 shared publicationAlessandro Russo
1 shared publication
Latest Publications
- Open Access
- 11 November 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 116
Aging, soiling, and cleaning effects on cool roof performance: Experimental insights on aerogel-based and conventional reflective coatings in Mediterranean climate
- 11 November 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 116
Open AccessAging, soiling, and cleaning effects on cool roof performance: Experimental insights on aerogel-based and conventional reflective coatings in Mediterranean climate
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Sensitivity analysis about the effectiveness of the energy efficiency measures for residential building under the Italian incentive opportunities
The strategic plan put in place by Italy to face this crisis aimed at environmental sustainability, was based on a tax deduction of 110% (divided into 5 annual quotas) aimed at promoting energy efficiency measures for existing buildings, even for fulfilling the new requirements of the energy efficiency in buildings and cities provided by the Directive EU 844/2018. This investigation, employing semi-stationary approach based on real case study and data, proposes a critical analysis of several passive and active energy efficiency measures for residential buildings, belonging to different climates. Considering the energy, and economic indicators, it is shown how it is really important to provide funding program for boosting the diffusion of energy efficiency measures. Indeed, also if the combination of measures on the building envelope and the HVAC system allows important energy saving (-60% -80%) the investment cost is still very high and the tenants may not be interested in the effects of a sustainable intervention if pay-back period is too high.
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Sensitivity analysis about the effectiveness of the energy efficiency measures for residential building under the Italian incentive opportunities
The strategic plan put in place by Italy to face this crisis aimed at environmental sustainability, was based on a tax deduction of 110% (divided into 5 annual quotas) aimed at promoting energy efficiency measures for existing buildings, even for fulfilling the new requirements of the energy efficiency in buildings and cities provided by the Directive EU 844/2018. This investigation, employing semi-stationary approach based on real case study and data, proposes a critical analysis of several passive and active energy efficiency measures for residential buildings, belonging to different climates. Considering the energy, and economic indicators, it is shown how it is really important to provide funding program for boosting the diffusion of energy efficiency measures. Indeed, also if the combination of measures on the building envelope and the HVAC system allows important energy saving (-60% -80%) the investment cost is still very high and the tenants may not be interested in the effects of a sustainable intervention if pay-back period is too high.
- 5 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Parametric analysis of energy savings achievable by windows configurations in different climates
The advent of the COVID-19 pandemic led to an economic crisis of the construction industry and to an increasing of energy consumption in the residential sector for all the world. These effects are added to those of climate change, requiring ever greater efficiency and sustain ability in buildings. The windows design and the windows replacement are critical aspects in the new and existing buildings, respectively. The proposed parametric analysis evaluates the effects of different window -system (thus glasses type and technology, frames and shields), conventional and innovative, on the total primary energy demand of an office, in different climatic locations. It is shown how the best configuration can be influenced by the window frame, the window orientation and the installation of internal or external shields. Considering also a smart-glass technology, the findings of this paper show that the approach adopted in a typical Mediterranean climate - where it is not enough to minimize only the energy need for heating or for cooling - is also valid in dominant heating or cooling climates. This study shows that an accurate design of windows can lead to significant savings in total primary energy. In particular, with reference to an office case study, the effect of solutions based on the solar gain control (low-e, selective glazing) was better than solutions based on the heat loss control (triple glazing), even in heating dominated climates. In Vienna and Split these configurations show the maximum total primary energy reduction, that is equal to $\approx - 38\%$ and $\approx -41\%$. compared to the base case $(\Delta \mathrm{E}_{\mathrm{P}})$, respectively.- 5 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Parametric analysis of energy savings achievable by windows configurations in different climates
The advent of the COVID-19 pandemic led to an economic crisis of the construction industry and to an increasing of energy consumption in the residential sector for all the world. These effects are added to those of climate change, requiring ever greater efficiency and sustain ability in buildings. The windows design and the windows replacement are critical aspects in the new and existing buildings, respectively. The proposed parametric analysis evaluates the effects of different window -system (thus glasses type and technology, frames and shields), conventional and innovative, on the total primary energy demand of an office, in different climatic locations. It is shown how the best configuration can be influenced by the window frame, the window orientation and the installation of internal or external shields. Considering also a smart-glass technology, the findings of this paper show that the approach adopted in a typical Mediterranean climate - where it is not enough to minimize only the energy need for heating or for cooling - is also valid in dominant heating or cooling climates. This study shows that an accurate design of windows can lead to significant savings in total primary energy. In particular, with reference to an office case study, the effect of solutions based on the solar gain control (low-e, selective glazing) was better than solutions based on the heat loss control (triple glazing), even in heating dominated climates. In Vienna and Split these configurations show the maximum total primary energy reduction, that is equal to $\approx - 38\%$ and $\approx -41\%$. compared to the base case $(\Delta \mathrm{E}_{\mathrm{P}})$, respectively.- 9 May 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 54, 104608
Experimental analysis of grills configuration for an open joint ventilated facade in summertime
- 9 May 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 54, 104608
Experimental analysis of grills configuration for an open joint ventilated facade in summertime
- 1 August 1994
- Published by Springer Nature in Surgical Endoscopy
- Vol. 8 (8) , 904-905
Large postoperative umbilical hernia following laparoscopic cholecystectomy
The authors report a case of large postoperative umbilical hernia following laparoscopic cholecystectomy, which occurred in the early postoperative period despite primary suture of the trocar insertion site. Forced dilation of the fascial layer is proposed as the etiological mechanism. This procedure should be avoided and an accurate and aseptic removal of the gallbladder should be performed in order to prevent risk of abdominal wall weakness and visceral herniation.
- 1 August 1994
- Published by Springer Nature in Surgical Endoscopy
- Vol. 8 (8) , 904-905
Large postoperative umbilical hernia following laparoscopic cholecystectomy
The authors report a case of large postoperative umbilical hernia following laparoscopic cholecystectomy, which occurred in the early postoperative period despite primary suture of the trocar insertion site. Forced dilation of the fascial layer is proposed as the etiological mechanism. This procedure should be avoided and an accurate and aseptic removal of the gallbladder should be performed in order to prevent risk of abdominal wall weakness and visceral herniation.