Kathirgamanathan Baskaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kathirgamanathan Baskaran has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Gamaralalage Chathura Samudika Jayaweera
Department of Architecture, Geology, Environment and Constructions, University of Liège, Liège, Belgium
1 shared publication - Hasitha Damruwan Hidallana-Gamage
Department of Civil Engineering, University of Moratuwa, Moratuwa 10400, Sri Lanka
1 shared publication M.G.V.N. Fernando
1 shared publication- Tissa Withanage Malith Chanaka Wanigasooriya
Department of Civil Engineering, University of Moratuwa, Moratuwa, Sri Lanka
1 shared publication Z.R. Dole
1 shared publication
Latest Publications
- 23 October 2025
- Published by Springer Nature in Glass Structures & Engineering
- Vol. 10 (4) , 1-27
Performance evaluation of laminated glass panels under large rigid missile impacts
- 23 October 2025
- Published by Springer Nature in Glass Structures & Engineering
- Vol. 10 (4) , 1-27
Performance evaluation of laminated glass panels under large rigid missile impacts
- 1 January 2025
- Published by University of Moratuwa
- p. 23-24
Study on methods of testing tensile strength of concrete
The tensile strength of concrete is a critical parameter in structural engineering, influencing crack resistance, durability, and overall performance. The brittle nature of concrete causes low tensile strength; hence, indirect methods for testing the tensile strength of concrete, such as the Direct Tension Test, Brazilian Splitting Test (BST), Flexural test, and other novel methods, present limitations related to stress distribution and real-world applicability. This research attempts to further investigate the applicability of a novel method by making certain improvements to past studies of a similar setup for determining the tensile strength of concrete using direct axial force and compares its performance with BST and Cube Compression Test (CCT) across different concrete ages and grades. The experimental procedure involved testing concrete grades C25 and C35 at 3, 7, 14, 28, and 56 days. Specimens were cast in separate batches and subjected to three testing methods: the novel method of Modified Direct Tension Test (MDTT), the Brazilian Splitting Test (BST), and a Cube Compression Test (CCT). The unstandardized MDTT specimen details, dimensions, and method of testing have been described, enabling further research on the proposed method. The novel method aims to provide a more representative measure of direct tensile behaviour while addressing limitations observed in BST. Tensile strength values obtained from both methods are analysed and compared, alongside cube compression test results, to establish correlations between tensile and compressive strengths. Preliminary findings suggest that the newly introduced method may offer improved reliability in capturing tensile failure mechanisms. The results also suggest that the tensile strength vs compressive strength gain patterns vary with time for both tensile strength testing methods. It was also found out that the novel method provides consistent results, and the specimen modification made to direct the tensile crack at the centre is successful in more than 80% of the cases. This research further attempts to discuss the practical applications for the MDTT in cases such as Precast concrete evaluation, bridge and tunnel structural performance, and FRC & UHPC strength and quality assessments. Modifications to be made to the testing apparatus to make it a more reliable method of testing the tensile strength of concrete are also discussed. Further recommendations have been provided to increase the number of test cases and investigate the influence of strain rate on the MDTT setup, which would contribute to the development of concrete testing methodologies as an alternative approach that would enhance accuracy and practical implementation in structural assessments.
- 1 January 2025
- Published by University of Moratuwa
- p. 23-24
Study on methods of testing tensile strength of concrete
The tensile strength of concrete is a critical parameter in structural engineering, influencing crack resistance, durability, and overall performance. The brittle nature of concrete causes low tensile strength; hence, indirect methods for testing the tensile strength of concrete, such as the Direct Tension Test, Brazilian Splitting Test (BST), Flexural test, and other novel methods, present limitations related to stress distribution and real-world applicability. This research attempts to further investigate the applicability of a novel method by making certain improvements to past studies of a similar setup for determining the tensile strength of concrete using direct axial force and compares its performance with BST and Cube Compression Test (CCT) across different concrete ages and grades. The experimental procedure involved testing concrete grades C25 and C35 at 3, 7, 14, 28, and 56 days. Specimens were cast in separate batches and subjected to three testing methods: the novel method of Modified Direct Tension Test (MDTT), the Brazilian Splitting Test (BST), and a Cube Compression Test (CCT). The unstandardized MDTT specimen details, dimensions, and method of testing have been described, enabling further research on the proposed method. The novel method aims to provide a more representative measure of direct tensile behaviour while addressing limitations observed in BST. Tensile strength values obtained from both methods are analysed and compared, alongside cube compression test results, to establish correlations between tensile and compressive strengths. Preliminary findings suggest that the newly introduced method may offer improved reliability in capturing tensile failure mechanisms. The results also suggest that the tensile strength vs compressive strength gain patterns vary with time for both tensile strength testing methods. It was also found out that the novel method provides consistent results, and the specimen modification made to direct the tensile crack at the centre is successful in more than 80% of the cases. This research further attempts to discuss the practical applications for the MDTT in cases such as Precast concrete evaluation, bridge and tunnel structural performance, and FRC & UHPC strength and quality assessments. Modifications to be made to the testing apparatus to make it a more reliable method of testing the tensile strength of concrete are also discussed. Further recommendations have been provided to increase the number of test cases and investigate the influence of strain rate on the MDTT setup, which would contribute to the development of concrete testing methodologies as an alternative approach that would enhance accuracy and practical implementation in structural assessments.
- 1 January 2025
- Published by University of Moratuwa
- p. 33-34
Plastic shrinkage in concrete structures with blended cement vs ordinary Portland cement
Plastic shrinkage cracking is a critical early-age problem in concrete structures that poses a direct threat to long-term durability, serviceability, and aesthetics. These cracks typically emerge within the first few hours after casting, as the surface moisture evaporates faster than it is replenished by bleeding. When restrained, this leads to tensile stresses that exceed the tensile strain capacity of the plastic concrete. The presence of such early-age cracks can result in increased permeability, accelerated corrosion of reinforcement, and compromised structural performance. Ordinary Portland Cement (OPC), due to its rapid hydration characteristics and relatively high bleeding rates, is known to be more susceptible to plastic shrinkage cracking. In contrast, Blended Hydraulic Cement (BHC), which contains supplementary cementitious materials (SCMs) such as fly ash and slag, is thought to enhance cohesion and reduce the rate of water loss, potentially offering better resistance against plastic shrinkage. This study aims to evaluate and compare the plastic shrinkage behaviour of concrete produced using OPC and BHC, with a special focus on tensile strain capacity. The primary objective is to measure and analyse the development of tensile strains in the plastic stage of concrete using Digital Image Correlation (DIC), a non-contact optical technique capable of capturing full-field surface strain data with high precision. Concrete mixes of grade 30 were prepared using both OPC and BHC. For each mix design, mechanical tests including compressive strength and splitting tensile strength were conducted at 7 days and 28 days. A specially designed test apparatus was used to simulate restrained conditions in fresh concrete and to evaluate plastic shrinkage behaviour. DIC was employed to monitor and quantify strain development at 2, 3, and 4 hours after casting. The results of the study indicate that concrete made with BHC exhibited a higher tensile strain capacity and demonstrated improved resistance to plastic shrinkage cracking compared to OPC. The difference in behaviour is attributed to the refined microstructure and reduced evaporation rates achieved using SCMs in BHC. The study further validates the reliability and effectiveness of DIC for early-age strain analysis, offering greater accuracy than traditional techniques. In addition, the comparative analysis revealed that while OPC mixes performed well in terms of early strength gain, they were consistently more prone to early cracking than BHC mixes under identical environmental conditions. In conclusion, this research highlights the significance of cement type and strain monitoring technology in addressing the problem of plastic shrinkage in concrete structures. By adopting blended cements and modern strain measurement methods, the risk of early cracking can be mitigated, leading to more durable and sustainable construction practices. These findings have practical implications for material selection and construction planning, especially in environments prone to rapid moisture loss.
- 1 January 2025
- Published by University of Moratuwa
- p. 33-34
Plastic shrinkage in concrete structures with blended cement vs ordinary Portland cement
Plastic shrinkage cracking is a critical early-age problem in concrete structures that poses a direct threat to long-term durability, serviceability, and aesthetics. These cracks typically emerge within the first few hours after casting, as the surface moisture evaporates faster than it is replenished by bleeding. When restrained, this leads to tensile stresses that exceed the tensile strain capacity of the plastic concrete. The presence of such early-age cracks can result in increased permeability, accelerated corrosion of reinforcement, and compromised structural performance. Ordinary Portland Cement (OPC), due to its rapid hydration characteristics and relatively high bleeding rates, is known to be more susceptible to plastic shrinkage cracking. In contrast, Blended Hydraulic Cement (BHC), which contains supplementary cementitious materials (SCMs) such as fly ash and slag, is thought to enhance cohesion and reduce the rate of water loss, potentially offering better resistance against plastic shrinkage. This study aims to evaluate and compare the plastic shrinkage behaviour of concrete produced using OPC and BHC, with a special focus on tensile strain capacity. The primary objective is to measure and analyse the development of tensile strains in the plastic stage of concrete using Digital Image Correlation (DIC), a non-contact optical technique capable of capturing full-field surface strain data with high precision. Concrete mixes of grade 30 were prepared using both OPC and BHC. For each mix design, mechanical tests including compressive strength and splitting tensile strength were conducted at 7 days and 28 days. A specially designed test apparatus was used to simulate restrained conditions in fresh concrete and to evaluate plastic shrinkage behaviour. DIC was employed to monitor and quantify strain development at 2, 3, and 4 hours after casting. The results of the study indicate that concrete made with BHC exhibited a higher tensile strain capacity and demonstrated improved resistance to plastic shrinkage cracking compared to OPC. The difference in behaviour is attributed to the refined microstructure and reduced evaporation rates achieved using SCMs in BHC. The study further validates the reliability and effectiveness of DIC for early-age strain analysis, offering greater accuracy than traditional techniques. In addition, the comparative analysis revealed that while OPC mixes performed well in terms of early strength gain, they were consistently more prone to early cracking than BHC mixes under identical environmental conditions. In conclusion, this research highlights the significance of cement type and strain monitoring technology in addressing the problem of plastic shrinkage in concrete structures. By adopting blended cements and modern strain measurement methods, the risk of early cracking can be mitigated, leading to more durable and sustainable construction practices. These findings have practical implications for material selection and construction planning, especially in environments prone to rapid moisture loss.