Wei Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wei Wei has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Hongji Meng
Institute of Automation Instrument, College of Information Science and Engineering, Northeastern University, Shenyang, China
1 shared publication - Jian Yang
School of Information Science and Engineering, Northeastern University, Shenyang 110819, China
1 shared publication - Zhenwei Hu
School of Information Science and Engineering, Northeastern University, Shenyang 110819, China
1 shared publication
Latest Publications
- Open Access
- 11 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (22) , 11981
A Billet Surface Temperature Measurement Method Based on a Water Mist Dehazing Network
In this paper, we present a water mist dehazing network to improve the accuracy of radiation temperature measurements of the billet surface in the secondary cooling zone of continuous casting. First, we develop a billet radiation attenuation model that accounts for the wavelength-dependent attenuation coefficient of water mist in the secondary cooling zone. Using this model and the corresponding dataset, the water mist transmittance is calculated. Furthermore, the water mist dehazing network—which is distinct from conventional dehazing networks designed for natural environments—comprises three key components: water mist feature extraction based on a combined Unet and Transformer structure; fusion of prior water mist transmittance data using an attention mechanism; and composite transmittance estimation via a multi-path dense network. The experimental results demonstrate that the proposed network effectively reduces water mist’s interference with billet surface temperature measurements in both the spatial and temporal dimensions. Compared with the standalone Unet and Unet + Transformer network architectures, the proposed network achieves a significantly improved dehazing performance, thus verifying its practical value and reliability for billet surface temperature measurement tasks.
- 11 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (22) , 11981
Open AccessA Billet Surface Temperature Measurement Method Based on a Water Mist Dehazing Network
In this paper, we present a water mist dehazing network to improve the accuracy of radiation temperature measurements of the billet surface in the secondary cooling zone of continuous casting. First, we develop a billet radiation attenuation model that accounts for the wavelength-dependent attenuation coefficient of water mist in the secondary cooling zone. Using this model and the corresponding dataset, the water mist transmittance is calculated. Furthermore, the water mist dehazing network—which is distinct from conventional dehazing networks designed for natural environments—comprises three key components: water mist feature extraction based on a combined Unet and Transformer structure; fusion of prior water mist transmittance data using an attention mechanism; and composite transmittance estimation via a multi-path dense network. The experimental results demonstrate that the proposed network effectively reduces water mist’s interference with billet surface temperature measurements in both the spatial and temporal dimensions. Compared with the standalone Unet and Unet + Transformer network architectures, the proposed network achieves a significantly improved dehazing performance, thus verifying its practical value and reliability for billet surface temperature measurement tasks.