WXWeiguo Xu

Weiguo Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Weiguo Xu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dynamic effects of lower limb mechanical-axis shift on medial meniscus posterior root radial tear

    by Chengyue Yu, Shuming Cao, Kexin Liu, Jingyu Zhang, Wenjun Zhao, Xiaoyuan Duan, Bo Liu, Lupeng Wang, Zhao Liu, Yongxin Huo, et al.

    Introduction: Lower limb mechanical alignment and medial meniscus posterior root radial tears (MMPRT) are considered risk factors for increased knee joint compartment loading, which may promote the development of osteoarthritis. MMPRT accounts for 21.5% of medial meniscus tears, with the medial meniscus posterior root radial tear (MMPRRT) being the most common type. Its occurrence is closely associated with dynamic loading of the knee joint during movement. This study aimed to establish a novel dynamic model of mechanical-axis shift and to investigate the biomechanical effects of mechanical-axis shift and tear length on MMPRRT under dynamic loading conditions. Methods: One healthy male volunteer was recruited. The volunteer had a neutral mechanical alignment confirmed by full-weight-bearing lower limb radiographs (R_HKA 0.44°, R_mMPTA 88.61°, R_mLDTA 87.07°, R_mLDFA 88.77°, R_JLCA 0.30°). CT and MRI data of the right knee were acquired. A finite element model of the knee joint at neutral alignment (0°) was established. A novel method for constructing mechanical-axis shift was proposed: only the load application point at the femoral end was translated in the medial–lateral direction to simulate mechanical-axis shifts, without directly modeling anatomical malalignment or altering the basic geometry and ligament tension of the knee joint. A total of six finite element models of MMPRRT under different mechanical-axis shift conditions were established, including medial mechanical-axis shifts equivalent to 3°, 6°, and 9°, and lateral mechanical-axis shifts equivalent to 3° and 6°. Dynamic analyses were performed using ISO-14243-3 gait loading. The finite element model at neutral alignment (0°) was validated using one cadaveric knee specimen under one static loading condition (1150 N), with the medial compartment contact area as the validation metric. Results: Under static loading, the error in medial compartment contact area between the finite element model and the cadaveric experiment was 5.72% for the intact meniscus condition. The peak contact pressure of each knee structure exhibited two peaks at 14% and 44% of the gait cycle. At neutral alignment (0°) and 14% of the gait cycle, the tear gap of the unstable posterior root radial tear was 48.75% larger than that of the stable tear. The maximum meniscal extrusion displacement was 2.69 mm, occurring at 44% of the gait cycle. A medial mechanical-axis shift elevated the medial peak contact pressure and prolonged the duration of high overall meniscal displacement, whereas a lateral mechanical-axis shift reduced the medial peak contact pressure and displacement. Discussion: This study established a dynamic finite element model of the knee joint with mechanical-axis shift and investigated the effects of mechanical-axis shift and tear length on MMPRRT biomechanics. The results showed that a medial mechanical-axis shift was associated with increased medial compartment loading, meniscal displacement, and tear gap, whereas a lateral mechanical-axis shift was associated with reduced medial loading. These biomechanical associations suggest that mechanical-axis shift may influence the local mechanical environment of MMPRRT. However, the clinical relevance of these findings requires further validation through prospective clinical studies incorporating multi-subject models and patient data.

  • Open Access

    Influence of constraint mechanism on kinematics, contact mechanics, and polyethylene wear in dual-axis rotating hinge and ball-and-socket knee prostheses: a finite element study

    by Jinwei Liu, Xiaoyi Wang, Chuanhao Guo, Yongcheng Hu, Weiguo Xu, Jingyu Zhang

    Background: Severe metaphyseal bone defects following revision total knee arthroplasty or tumor resection often require highly constrained knee prostheses. Although rotating hinge knee (RHK) designs provide reliable stability, polyethylene wear and aseptic loosening remain important concerns. A novel ball-and-socket knee prosthesis has been developed to improve rotational accommodation and joint kinematics; however, its biomechanical performance relative to conventional rotating hinge designs remains unclear. Methods: Finite element models of a dual-axis rotating hinge knee prosthesis and a ball-and-socket knee prosthesis were developed and subjected to five million gait cycles under ISO 14243-1:2009 loading and motion conditions. Kinematics, contact mechanics, and polyethylene wear were evaluated using a contact-pressure-independent modified Archard wear formulation incorporating cross-shear effects. The reported wear volume for the ball-and-socket prosthesis represents the analyzed bearing side and its associated constraint interfaces. Results: Both prosthetic designs exhibited limited anterior–posterior translation and maintained relatively low contact pressures due to highly conforming articulations. Compared with the dual-axis rotating hinge prosthesis, the ball-and-socket prosthesis demonstrated greater internal–external rotational freedom (21.6° vs. 3.2°) and broader contact migration during gait. Although the ball-and-socket design exhibited larger contact areas and lower contact pressures, its polyethylene wear rate (10.06 mm 3 /million cycles) was higher than that of the dual-axis prosthesis (1.78 mm 3 /million cycles). This difference corresponded to the greater multidirectional motion and cross-shear conditions observed in the ball-and-socket design. Conclusion: Prosthetic design influences kinematics, contact mechanics, and wear behavior in highly constrained knee systems. The results indicate that multidirectional motion and cross-shear may play a more important role in polyethylene wear than contact pressure alone. Although the ball-and-socket prosthesis exhibited greater wear than the dual-axis design, it provided increased rotational accommodation and may better accommodate rotational demands during gait. These features support its potential as an alternative design strategy for constrained knee reconstruction after further experimental validation and design optimization. Future optimization should focus on reducing excessive multidirectional sliding and cross-shear while preserving rotational adaptability.

  • Open Access

    Finite element analysis of medial meniscus tears and related surgical techniques with biomechanical validation

    by Chengyue Yu, Kexin Liu, Jingyu Zhang, Wenjun Zhao, Xiaoyuan Duan, Bo Liu, Lupeng Wang, Zhao Liu, Yongxin Huo, Tao Zhang, et al.

    Introduction: This study established finite element models of the knee incorporating radial and longitudinal meniscal tears and simulated corresponding surgical techniques to investigate the influence of different tear types, lengths, locations on stress distribution in the knee joint and evaluate the restorative effects of different surgical techniques on the biomechanical performance of the meniscus. Methods: A three-dimensional finite element model of the right knee including bone and soft tissues was developed. Stable and unstable radial and longitudinal tear models were created in the posterior horn of the meniscus across three zones (white-white, red-white, and red-red zones), together with the corresponding surgical technique models (suture repair and partial meniscectomy). Finite element analysis was performed under static loading. A cadaveric knee biomechanical experiment was also conducted to validate the finite element model. Results: Under static loading, the discrepancy in medial compartment contact area between the finite element model and the cadaveric experiment under intact meniscus conditions was 5.72%. The peak contact pressure was highest in the unstable radial tear model, reaching 14.88 MPa, representing an 181.82% increase compared with 5.28 MPa measured in the intact meniscus. Both repair and partial meniscectomy significantly reduced the peak contact pressure in the medial meniscus and tibial cartilage for radial tears. Repair reduced the peak pressure by 35.35% for stable radial tears, while partial meniscectomy reduced it by 49.60% for unstable radial tears. Meniscal repair reduced the peak contact pressure by 4.55% and 3.85% for stable longitudinal tears located in the red and white zones, respectively, and restored hoop stress transmission. Partial meniscectomy reduced the peak contact pressure by 7.90% (0.67 MPa) for unstable longitudinal tears located in the white zone. Conclusion: Stress distribution in the meniscus and its components is influenced by tear types, locations, lengths, and surgical technique. Surgical outcomes significantly depend on tear types, lengths, and locations. The extent of biomechanical restoration varies considerably among different surgical techniques, suggesting that clinical procedure selection should be based on personalized consideration of injury characteristics.

  • Open Access

    Changes in lower limb muscle strength and corresponding gait changes following hip fractures in older adults: a narrative review

    by Wei Wang, Yang Liu, Ce Wang, Yaomin Li, Weiguo Xu

    This narrative review synthesizes available evidence on changes in lower limb muscle strength and corresponding gait alterations following hip fracture in older adults, aiming to provide a biomechanically grounded framework for precision rehabilitation. A structured literature search was conducted across major electronic databases (PubMed, Scopus, Web of Science, Embase, and the Cochrane Library) from inception to January 31, 2026, and findings were synthesized descriptively. The evidence indicates that muscle strength decline exhibits group-specific patterns: hip abductor weakness is associated with pelvic instability and Trendelenburg gait; quadriceps atrophy correlates with knee instability and limited flexion-extension; and weakness of the gluteus maximus and calf muscles appears linked to reduced stride length and diminished propulsive force. Recovery of muscle strength and gait typically follows a trajectory of rapid decline, gradual improvement within the first six months, and long-term persistence of sub-baseline levels, with bilateral asymmetry often lasting 1–2 years post-surgery; gait speed, stride length, and symmetry frequently remain impaired despite rehabilitation. These findings suggest that biomechanically informed, muscle group-specific training—guided by individual gait analysis—may enhance functional recovery and reduce fall risk, encouraging clinicians to move beyond generic lower-limb strengthening programs toward targeted, mechanism-based interventions.

  • Open Access

    Application of axial load-share ratio testing technology in the bone transport treatment of large segmental tibial bone defects

    by Zhao Liu, Ming Cai, Yu Gou, Xun Sun, Xuan Yang, Zhiming Zhao, Hongzhou Li, Ningning Zhang, Chengkuo Cai, Xiaolong Mei, et al.

    Bone transport is a widely established method for treating tibial bone defects. However, safely removing the external fixator as early as possible to shorten treatment duration remains a clinical challenge. This study aimed to investigate whether axial load-share ratio (ALSR) testing can safely and effectively assess callus healing strength at the mineralization zone and docking site, and thereby guide the precise timing of external fixator removal during tibial bone transport. This retrospective study included 42 adult patients with tibial bone defects treated by bone transport between 2019 and 2025. Patients were divided into the ALSR group (n = 20) and conventional group (n = 22) according to the external fixation removal strategy used. In the ALSR group, ALSR testing was performed to evaluate healing strength at the mineralization zone and docking site. In the ALSR group, staged removal of external fixation was considered when ALSR testing showed a value < 5%, in combination with clinical examination and radiographic evidence. In the conventional group, we based removal decisions on standard clinical and radiographic criteria. We compared the following clinical indicators between groups: operative time, intraoperative blood loss, bone transport duration, healing time of the mineralization zone, healing time of the docking site, external fixation duration, and external fixation index. At the final follow-up, we used the Association for the Study and Application of the Method of Ilizarov (ASAMI) scoring system to assess bone healing and functional recovery and performed relevant statistical analyses. The median bone transport duration was 82.50 (IQR,63.5-109.5) days in the ALSR group and 71.50 (IQR,64.00- 120) days in the conventional group(P > 0.05). The median healing time of the mineralization zone was 182.00 days (IQR,155.25-219.75) in the ALSR group, significantly shorter than 205.50 days (IQR,177.25-285.75) in the conventional group (P < 0.05). The median healing time of the docking site was 207.50 days (IQR,189.00-262.50) in the ALSR group, significantly shorter than 259.50 days (IQR,222.5-332.50) in the conventional group(P < 0.05). The median external fixation duration, which was defined as the primary endpoint, was 219.00 days (IQR, 205.50-277.25) in the ALSR group, significantly shorter than 274.00 days (IQR, 238.25-347.00) in the conventional group (P < 0.05). The external fixation index was 33.25 ± 4.97 d/cm in the ALSR group, significantly lower than 40.05 ± 9.39 d/cm in the conventional group (P < 0.05). At the final follow-up, there was no statistically significant difference in ASAMI scores and complications between the two groups (P > 0.05). Following bone transport surgery for large segmental tibial bone defects, ALSR testing provides a quantitative and reliable method for evaluating callus strength during bone transport. It enables earlier and safer removal of external fixation, reducing treatment duration without compromising clinical outcomes.

  • Open Access

    Injectable ROS-scavenging and NIR-responsive nanocomposite hydrogel for staphylococcus aureus-infected diabetic wound healing

    by Ming Cai, Zhao Liu, Xun Sun, Ziming Liao, Yu Gou, Xuan Yang, Ying Qi, Guosheng Xing, Tingting Liu, Wenjun Zhao, et al.

    Chronic diabetic wounds are often complicated by persistent infections and oxidative stress, which impede effective healing. In this study, we developed an injectable, dual-responsive nanocomposite hydrogel designed to simultaneously scavenge reactive oxygen species (ROS) and deliver photothermal and photodynamic therapy for wound treatment. The hydrogel was synthesized via dynamic boronate-ester crosslinking of poly(vinyl alcohol) (PVA) with a bis-boronic acid linker (TSPBA), enabling efficient ROS quenching. Incorporation of palygorskite/molybdenum disulfide (PGS/MoS₂) nanocomposites imparted photothermal and photodynamic properties, activated by NIR light. In vitro tests demonstrated that the PVA-TSPBA@PGS/MoS₂ hydrogel effectively scavenged ROS, induced mild hyperthermia (~ 48 °C) under NIR, and exhibited significant antibacterial activity against Staphylococcus aureus. In vivo, the hydrogel accelerated wound closure in a diabetic mouse model, with a 46.7% residual area at day 7, compared to higher residual areas in control groups (66.5–92.4%). By day 14, nearly complete wound healing was achieved, accompanied by reduced bacterial load and inflammatory markers, as well as enhanced re-epithelialization, angiogenesis, and collagen remodeling. These findings suggest that this multifunctional hydrogel represents a promising strategy for the treatment of infected diabetic wounds, offering a controlled, localized approach to wound healing. Graphical Abstract