LHLandon Hernandez

Landon Hernandez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Landon Hernandez has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Braden Giordano

    U.S. Naval Research Laboratory, 4555 Overlook Ave, SW, Washington, DC 20375, USA

    6 shared publications
  • Cathy Scotto

    U.S. Naval Research Laboratory, 4555 Overlook Ave, SW, Washington, DC 20375, USA

    6 shared publications
  • Jay Eversole

    Naval Research Laboratory Optical Sciences Division (Washington, United States of America)

    6 shared publications
  • Kenneth Grabowski

    U.S. Naval Research Laboratory, 4555 Overlook Ave, SW, Washington, DC 20375, USA

    6 shared publications
  • Mark Hammond

    U.S. Naval Research Laboratory, 4555 Overlook Ave, SW, Washington, DC 20375, USA

    6 shared publications
  • Matthew Hart

    U.S. Naval Research Laboratory, 4555 Overlook Ave, SW, Washington, DC 20375, USA

    6 shared publications

Latest Publications

  • Open Access

    Development and validation of an integrated Ambient Air Test Facility (AATF) for multi-instrument aerosol characterization

    by Paul Johns, Cathy Scotto, Landon Hernandez, Matthew Hart, Oyedoyin Aduroja, Mark Hammond, Braden Giordano, Kenneth Grabowski, Jay Eversole, Vasanthi Sivaprakasam

    The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 m flow tube system that provides turbulent ( R e =40 000) outdoor ambient air flow at 2 m s −1 for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3000 µg m −3 and the ability to detect particles across a mean diameter range of 50 nm to 15 µm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼ 100, medium ∼ 500, high >800 µg m −3 ). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5 %. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20 % difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument inter-comparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.

  • Open Access

    Comment on egusphere-2025-6043

    by Paul Johns, Cathy Scotto, Landon Hernandez, Matthew Hart, Oyedoyin Aduroja, Mark Hammond, Braden Giordano, Kenneth Grabowski, Jay Eversole, Vasanthi Sivaprakasam

    The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.

  • Open Access

    Reply on RC1

    by Paul Johns, Cathy Scotto, Landon Hernandez, Matthew Hart, Oyedoyin Aduroja, Mark Hammond, Braden Giordano, Kenneth Grabowski, Jay Eversole, Vasanthi Sivaprakasam

    The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.

  • Open Access

    Comment on egusphere-2025-6043

    by Paul Johns, Cathy Scotto, Landon Hernandez, Matthew Hart, Oyedoyin Aduroja, Mark Hammond, Braden Giordano, Kenneth Grabowski, Jay Eversole, Vasanthi Sivaprakasam

    The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.

  • Open Access

    Supplementary material to "Development and Validation of an Integrated Ambient Air Test Facility (AATF) for Multi-Instrument Aerosol Characterization"

    by pAul Johns, Cathy Scotto, Landon Hernandez, Matthew Hart, Oyedoyin Aduroja, Mark Hammond, Braden Giordano, Kenneth Grabowski, Jay Eversole, Vasanthi Sivaprakasam

  • Open Access

    Development and Validation of an Integrated Ambient Air Test Facility (AATF) for Multi-Instrument Aerosol Characterization

    by pAul Johns, Cathy Scotto, Landon Hernandez, Matthew Hart, Oyedoyin Aduroja, Mark Hammond, Braden Giordano, Kenneth Grabowski, Jay Eversole, Vasanthi Sivaprakasam

    The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.


  • Open Access

    Portable Dynamic Laser Speckle Imaging for Rapid Antimicrobial Susceptibility Testing

    by Jinkai Yang, Keren Zhou, Landon Hernandez, Chen Zhou, Olena Voloshchuk, Jasna Kovac, Aida Ebrahimi, Zhiwen Liu

    Antimicrobial resistance remains a pressing global health threat. Conventional antimicrobial susceptibility testing (AST) methods are limited by long incubation times and centralized laboratory requirements, hindering timely decision-making in resource-limited settings. This study introduces a 3D printed, portable dynamic laser speckle imaging (pDLSI) device for rapid AST. This device has a 10 × 3 × 3 cm 3 footprint, equipped with a low-cost laser diode, a lens assembly, and a cuvette sample holder. Speckle fluctuations induced by bacterial activity are captured on a cellphone camera, visualized using spatiotemporal decorrelation maps, and analyzed using machine learning to determine minimum inhibitory concentrations within 2–3 h. To demonstrate the performance, we studied two representative Gram-positive and Gram-negative bacterial strains ( Enterococcus faecalis and Escherichia coli ), along with two antibiotics (ampicillin and gentamicin). The simple construction, portability, and intuitive operation of the pDLSI system can potentially facilitate initial diagnostic decisions at the point of care.