CEChinonso S. Ezeonye

Chinonso S. Ezeonye

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chinonso S. Ezeonye has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • A.A. Adeyi

    Department of Electrical/Electronic Engineering, Maritime Academy of Nigeria, Oron, Akwa Ibom State

    1 shared publication
  • Abba M. O.

    Department of Electrical & Electronic Engineering, Enugu State University of Science and Technology, Agbani, Enugu State

    1 shared publication
  • Abimbola A. Adeyi

    Department of Electrical/Electronic Engineering, Maritime Academy of Nigeria, Oron, Akwa Ibom State

    1 shared publication
  • Chukwuchekwa N.

    Department of Electrical & Electronic Engineering, Federal University of Technology, Owerri, Imo State

    1 shared publication
  • Ifeanyichukwu K. Onwuka

    Department of Electrical & Electronic Engineering, Michael Okpara University of Agriculture, Umudike, Abia State

    1 shared publication
  • Izuegbunam F. I.

    Department of Electrical & Electronic Engineering, Federal University of Technology, Owerri, Imo State

    1 shared publication

Latest Publications

  • Open Access

    Investigating Electricity Power Grid Collapses in Nigeria and Measures to Reduce its Effect During Occurrence

    by Patrick I. Obi, Chinonso S. Ezeonye, Abimbola A. Adeyi, Ifeanyichukwu K. Onwuka, Osita Oputa

    Nigeria’s power grid has been characterised by frequent collapses, leading to significant economic losses and disruptions across critical sectors. These failures have been attributed to various operational challenges including voltage instability and insufficient reactive power support, which are key vulnerability factors that aggravate grid disturbances and impede quick system recovery. The persistence of these partial or total voltage collapse events continues to degrade the national economy and the reliability of the electricity system. This study examines the grid performance data from the National Control Centre (NCC), Osogbo for the period 2000 to 2025 along with proffered mitigation measures utilising shunt compensators, solar generation and Adaptive Genetic Algorithm (AGA) optimisation. A 48-bus transmission system is developed to evaluate voltage stability under various compensation schemes. The results indicate that AGA optimisation significantly enhances the stability of power grids by adaptively optimising the compensator placement, increasing the average bus voltage from 297.39 ± 1.05 kV under baseline conditions to 309.20 ± 1.04 kV after optimization. This is better than the performances of the standalone shunt (301.85 ± 1.08 kV) and solar (307.29 ± 1.08 kV) compensators. The results indicate that heuristic-based optimisation can provide a robust and adaptive approach for improving voltage stability and reducing grid vulnerability. It is therefore suggested that AGA-based optimisation be implemented into the Nigeria’s power grid management to enhance voltage regulation and system resilience. Increasing integration of renewable energy, particularly solar, will additionally boost grid resiliency, while future work should focus on real-time adaptive control for sustainable grid operation in dynamic conditions.


  • Open Access

    Quantitative Evaluation of Magnetic Flux Line Compactness and Symmetry for Transformer Core Material Ranking

    by Osuji U., Ezeonye C. S., Abba M. O., Chukwuchekwa N., Onojo O. J., Izuegbunam F. I., Okafor E. N. C.

    The study presents the simulation-based method for evaluating transformer core materials by considering the spatial nature of magnetic flux lines. The aim is to broaden the design space of materials compared with those conventionally characterised solely by relative permeability and core loss by introducing a pair of field-distribution indices; the compactness index (CI) and symmetry index (SI). Five fundamental materials, Metglas, Silicon Steel, Ferrite, Soft Iron and Solid Iron, were investigated through MATLAB simulation with the basis of a simplified excitation model. Vector field analysis, flux density surface maps, radial flux profile, and angular flux responses were described for each material magnetic features. The simulation results revealed that the best efficiency obtained was Metglas with a compactness index of 99.17, then silicon steel, soft iron, ferrite and solid iron with 44.10, 41.30, 30.08, and 21.74 respectively. The peak value of the flux density for Metglas was about 0.30 T measured just outside the inner radius at r = 0.03 m under a 1 A excitation, and about 0.18 T at r = 0.05 m used for the angular profile. The symmetry index was unity for all materials, ensuring the magnetic field distribution was perfectly balanced in the symmetric excitation geometry. These results demonstrate that while magnetic symmetry is preserved across materials in this geometry, the CI yields a relevant quantitative difference in field performance. The study therefore offers a refined basis for evaluating transformer core materials through a geometry oriented framework that can support compact and thermally stable transformer designs. The results are consistent with analytical expectations and recent FEA studies, highlighting the relevance of CI and SI for modern power systems where magnetic performance must be maximised in compact designs.

  • Open Access

    Direct Power Control of Doubly Fed Induction Generator for Grid-Connected Wind Applications

    by C. S. Ezeonye, O. Oputa, U. Osuji, A.A. Adeyi, P.I. Obi

    The control of wind power systems with doubly-fed induction generators presents significant technical challenges, particularly in the presence of grid faults, torque ripple and harmonic distortion. This study proposes a model-based direct power control technique to enhance the dynamic performance and power quality of DFIGs under varying operating conditions. A rotor voltage controller based on proportional-integral action is considered to control the active and reactive power. The performance of the model is simulated in cases of wind torque variation, grid voltage sag, parameter deviations, and harmonic distortion scenarios, as well as scaling tests for different machine ratings. Results demonstrate obvious improvements with respect to torque ripple suppression, total harmonic distortion mitigation, and system response time in comparison to conventional VOC and classical DPC. In that regard, the proposed controller obtains a THD of 3.4%, meets IEEE 519 limits, and matches or surpasses advanced DPC variants reported in the literature in terms of torque ripple and recovery time, while exhibiting slightly higher THD than NF-DPC under identical conditions. These results indicate that this control can improve the reliability and quality of the power of wind energy systems connected to the modern grids.