Il Kim
Research Subjects
Il Kim has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Byeong-Ha Kim
BH 3D Art Center, Seoul 04782, Republic of Korea
2 shared publications - Donghun Yang
Research Data Center, Korea Institute of Science and Technology Information, Daejeon, Republic of Korea
2 shared publications - Hyeong-Seok Choi
Ewha Medical Academy, Ewha Womans University Medical Center, Seoul 07804, Republic of Korea
2 shared publications - Ji-Young Son
Department of Anatomy, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
2 shared publications - Sang-Chul Choi
Ewha Medical Academy, Ewha Womans University Medical Center, Seoul 07804, Republic of Korea
2 shared publications - Seung-Ho Han
Department of Anatomy, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 11 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 13047
Implementation of an Interactive Clinical Simulator Based on Facial Anatomy: An Enhanced Model for Injection Training
Minimally invasive facial procedures are widely performed in clinical medicine but remain associated with severe complications such as necrosis or blindness, often resulting from insufficient anatomical understanding and limited procedural training. To address these challenges, this study developed an anatomically accurate clinical simulator for facial injection training. A three-dimensional polygonal facial model was constructed using standardized anatomical datasets reflecting skeletal dimensions, soft tissue characteristics and the average arterial distribution of East Asian faces. This model was integrated into simulation software connected to a facial silicone dummy with realistic tissue texture and an optical tracking system providing sub-millimeter precision. Each anatomical structure, including muscles, vessels and nerves, was digitally annotated and linked to interactive visualization tools. During training, the simulator simultaneously reflected the real-time needle trajectory and insertion depth; when the needle tip approached a high-risk structure, such as the supraorbital artery, alerts were automatically triggered. This feedback enabled trainees to recognize unsafe injection zones and adjust their technique accordingly. The system provided a realistic, repeatable and safe environment for improving anatomical comprehension and procedural accuracy. This study proposes an innovative applied simulation system that may enhance medical education and clinical safety in facial injection procedures.
- 11 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 13047
Open AccessImplementation of an Interactive Clinical Simulator Based on Facial Anatomy: An Enhanced Model for Injection Training
Minimally invasive facial procedures are widely performed in clinical medicine but remain associated with severe complications such as necrosis or blindness, often resulting from insufficient anatomical understanding and limited procedural training. To address these challenges, this study developed an anatomically accurate clinical simulator for facial injection training. A three-dimensional polygonal facial model was constructed using standardized anatomical datasets reflecting skeletal dimensions, soft tissue characteristics and the average arterial distribution of East Asian faces. This model was integrated into simulation software connected to a facial silicone dummy with realistic tissue texture and an optical tracking system providing sub-millimeter precision. Each anatomical structure, including muscles, vessels and nerves, was digitally annotated and linked to interactive visualization tools. During training, the simulator simultaneously reflected the real-time needle trajectory and insertion depth; when the needle tip approached a high-risk structure, such as the supraorbital artery, alerts were automatically triggered. This feedback enabled trainees to recognize unsafe injection zones and adjust their technique accordingly. The system provided a realistic, repeatable and safe environment for improving anatomical comprehension and procedural accuracy. This study proposes an innovative applied simulation system that may enhance medical education and clinical safety in facial injection procedures.
- Open Access
- 19 November 2025
- Published by MDPI AG in Preprints.org
Implementation of an Interactive Clinical Simulator Based on Facial Anatomy: An Enhanced Model for Injection Training
Minimally invasive facial procedures are widely performed in clinical medicine but re-main associated with severe complications such as necrosis or blindness, often resulting from insufficient anatomical understanding and limited procedural training. To address these challenges, this study developed an anatomically accurate clinical simulator for fa-cial injection training. A three-dimensional polygonal facial model was constructed using standardized anatomical datasets reflecting skeletal dimensions, soft tissue characteris-tics and the average arterial distribution of East Asian faces. This model was integrated into simulation software connected to a facial silicone dummy with realistic tissue texture and an optical tracking system providing sub-millimeter precision. Each anatomical structure, including muscles, vessels and nerves, was digitally annotated and linked to interactive visualization tools. During training, the simulator simultaneously reflected the real-time needle trajectory and insertion depth; when the needle tip approached a high-risk structure, such as the supraorbital artery, alerts were automatically triggered. This feedback enabled trainees to recognize unsafe injection zones and adjust their tech-nique accordingly. The system provided a realistic, repeatable and safe environment for improving anatomical comprehension and procedural accuracy. This study proposes an innovative applied simulation system that may enhance medical education and clinical safety in facial injection procedures.
- 19 November 2025
- Published by MDPI AG in Preprints.org
Open AccessImplementation of an Interactive Clinical Simulator Based on Facial Anatomy: An Enhanced Model for Injection Training
Minimally invasive facial procedures are widely performed in clinical medicine but re-main associated with severe complications such as necrosis or blindness, often resulting from insufficient anatomical understanding and limited procedural training. To address these challenges, this study developed an anatomically accurate clinical simulator for fa-cial injection training. A three-dimensional polygonal facial model was constructed using standardized anatomical datasets reflecting skeletal dimensions, soft tissue characteris-tics and the average arterial distribution of East Asian faces. This model was integrated into simulation software connected to a facial silicone dummy with realistic tissue texture and an optical tracking system providing sub-millimeter precision. Each anatomical structure, including muscles, vessels and nerves, was digitally annotated and linked to interactive visualization tools. During training, the simulator simultaneously reflected the real-time needle trajectory and insertion depth; when the needle tip approached a high-risk structure, such as the supraorbital artery, alerts were automatically triggered. This feedback enabled trainees to recognize unsafe injection zones and adjust their tech-nique accordingly. The system provided a realistic, repeatable and safe environment for improving anatomical comprehension and procedural accuracy. This study proposes an innovative applied simulation system that may enhance medical education and clinical safety in facial injection procedures.
- Open Access
- 12 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (22) , 12002
Development and Evaluation of a Next-Generation Medication Safety Support System Based on AI and Mixed Reality: A Study from South Korea
Medication errors pose a significant threat to patient safety. Although Bar-Code Medication Administration (BCMA) has reduced error rates, it is constrained by handheld devices, workflow interruptions, and incomplete safeguards against wrong patients, wrong doses, or drug incompatibility. In this study, we developed and evaluated a next-generation BCMA system by integrating artificial intelligence and mixed reality technologies for real-time safety checks: Optical Character Recognition verifies medication–label concordance, facial recognition confirms patient identity, and a rules engine evaluates drug–diluent compatibility. Computer vision models achieved high recognition accuracy for drug vials (100%), medication labels (90%), QR codes (90%), and patient faces (90%), with slightly lower performance for intravenous fluids (80%). A mixed-methods evaluation was conducted in a simulated environment using the System Usability Scale (SUS), Reduced Instructional Materials Motivation Survey (RIMMS), Virtual Reality Sickness Questionnaire (VRSQ), and NASA Task Load Index (NASA-TLX). The results indicated excellent usability (median SUS = 82.5/100), strong user motivation (RIMMS = 3.7/5), minimal cybersickness (VRSQ = 0.4/6), and manageable cognitive workload (NASA-TLX = 31.7/100). Qualitative analysis highlighted the system’s potential to streamline workflow and serve as a digital “second verifier.” These findings suggest strong potential for clinical integration, enhancing medication safety at the point of care.
- 12 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (22) , 12002
Open AccessDevelopment and Evaluation of a Next-Generation Medication Safety Support System Based on AI and Mixed Reality: A Study from South Korea
Medication errors pose a significant threat to patient safety. Although Bar-Code Medication Administration (BCMA) has reduced error rates, it is constrained by handheld devices, workflow interruptions, and incomplete safeguards against wrong patients, wrong doses, or drug incompatibility. In this study, we developed and evaluated a next-generation BCMA system by integrating artificial intelligence and mixed reality technologies for real-time safety checks: Optical Character Recognition verifies medication–label concordance, facial recognition confirms patient identity, and a rules engine evaluates drug–diluent compatibility. Computer vision models achieved high recognition accuracy for drug vials (100%), medication labels (90%), QR codes (90%), and patient faces (90%), with slightly lower performance for intravenous fluids (80%). A mixed-methods evaluation was conducted in a simulated environment using the System Usability Scale (SUS), Reduced Instructional Materials Motivation Survey (RIMMS), Virtual Reality Sickness Questionnaire (VRSQ), and NASA Task Load Index (NASA-TLX). The results indicated excellent usability (median SUS = 82.5/100), strong user motivation (RIMMS = 3.7/5), minimal cybersickness (VRSQ = 0.4/6), and manageable cognitive workload (NASA-TLX = 31.7/100). Qualitative analysis highlighted the system’s potential to streamline workflow and serve as a digital “second verifier.” These findings suggest strong potential for clinical integration, enhancing medication safety at the point of care.